1/2"
COLD
WATER
INLET
VENT
3/4"
OVERFLOW
BELOW COUNTER CONNECTIONS
ABOVE COUNTER
CONNECTIONS
* Dimension D can be increased to a maximum of 203mm by fitting of alternative tap bodies.
(See spare parts page 16)
MODEL
A
B
C
D*
E
DRY
WEIGHT
WORKING
WEIGHT
CB32
CB22
CB12
mm 457 340 260 152 250 11.5 KG
31KG
OVERFLOW
The overflow connection should be plumbed to a safe and visible
point of discharge using 22mm diameter pipe. “NOT A CLOSED
WASTE”.
BELOW COUNTER CONNECTIONS can be concealed inside
the outer casing to make a neat installation.
ABOVE COUNTER CONNECTIONS can be made after
removing the blanking plugs at the rear of the outer casing.
ELECTRICAL CONNECTIONS
The boiler should be connected to a 220-240v , 50-60 Hz
electrical supply, in accordance with current I.E.E. Regulations.
The incoming cable must be heat resistant and clamped
securely using the supplied strain relief bar. A means for all pole
disconnection must be incorporated, including appropriately
rated fuse. The installation of a residual current device (RCD)
having a rated residual operating current not exceeding 30 mA is
advisable.
An equipotential conductor connection terminal is provided on the
rear of the unit.
The supply should be connected as follows:
Brown-----------------Live
L
Blue--------------------Neutral
N
Green / Yellow-------Earth
Cable entry can be made either from under the counter (through
the base) or above counter ( through the rear casing of the unit).
If the cable enters through the rear, a hole must be pierced in
the rubber entry grommet that protects the cable from sharp
metalwork.
GENERAL
The boiler vent on the lid must not be obstructed by placing
anything over the outlet, or in close proximity above it.
After the water supply has been switched on, make sure there
are no leaks and that the boiler, all pipe work and fittings are dry
before replacing the boiler side panel and lid.
Remove protective vinyl coating from all metalwork before use.
*