2.2.1

 

Settings accessible as “User” (Level 1)

 

“User” level is the first level providing access to certain functions of the R4000. 

 

The first step therefore consists in logging in as a user.  
 

2.2.1.1

 

Logging in 

 

Enter “

USER

” in the login tab 

, then enter the password you have been given in the 

 tab 

 

Then click on the 

 

icon which appears in the greyed “Conne

ction

” part to connect and return to 

the main screen. 

 

 

Figure 6: connection by login and password 

 
N.B. The user is automatically logged out after a period of inactivity which can be configured (in the previous 

example in Figure 6, it is 300 seconds). It is also possible to log out manually by clicking on the 

 icon. 

 

 

 

Figure 7

: main screen once logged in in “User” mode

 

 

 

User connected

 status then appears in green at the top left of the screen. 

 
N.B. Even when the R4000 is stopped it is normal to notice differences in temperature and humidity between 
the return (air inlet at the bottom of the machine) and the supply (air outlet at the top of the machine) 

Содержание R4000

Страница 1: ...R4000 MOBILE AIR HANDLING UNIT USER GUIDE...

Страница 2: ...enabling it to manage all the programmed functions via the various built in sensors Its automatic regulation system enables it to maintain the desired air flow however clogged its filters are or to a...

Страница 3: ...e unit is composed of a galvanised steel double wall with rock wool thermal and acoustic insulation double skin The inner and outer walls are smooth avoiding the formation of biofilms NF S90 351 stand...

Страница 4: ...t is equipped with a latest generation SAIA PLC PCD3 M90 type It enables the air handling unit to operate independently maintaining a constant flow however clogged the filters are It manages all the s...

Страница 5: ...teel connection mounted on the unit by tightening on a seal It can thus be connected to ducts of diameters ranging from 150 DN150 to 400 mm DN400 Other connection components are available consult us F...

Страница 6: ...to air ducts via its supply kit or its return kit In all cases this type of installation requires a prior study followed by a Design Qualification DQ an Installation Qualification IQ and an Operationa...

Страница 7: ...of the machine switches on and displays the main screen For practical reasons the R4000 is displayed horizontally on the screen The air inlet bottom of the machine is shown on the left and the air ou...

Страница 8: ...erform maintenance on the machine and who will therefore have access to additional functions Level 3 Administrator login ADMIN is used to configure the machine for the use for which it is intended mob...

Страница 9: ...t to connect and return to the main screen Figure 6 connection by login and password N B The user is automatically logged out after a period of inactivity which can be configured in the previous examp...

Страница 10: ...sometimes results in slight differences in pressure loss in the filters 2 2 1 2 Settings configuration Click on the Tools icon to configure the settings for the air treatment flows during the day and...

Страница 11: ...return and at the outlet also called supply of the air consumed power of the fan motorised impeller and the UV bulb stages stages 1 and 2 the pressure and air flow of the fan and the pressure losses o...

Страница 12: ...he energy meter for a bulb stage The log displays an alarm on the UV bulbs of level 2 fault no 9 and instantly determines that the failure is linked to the energy meter fault no 18 Following this we s...

Страница 13: ...it In the event of a power outage when the power returns the R4000 restarts according to the last operating settings No physical intervention is necessary 2 2 2 Settings accessible as Technical Person...

Страница 14: ...14 21 Figure 14 connection by login and password Technician connected status then appears in green at the top left of the screen Figure 15 main screen once logged in in Technician mode 2 2 2 2 Settin...

Страница 15: ...sed impeller maximum or minimum power percentage Motorised impeller minimum for the fan or a fixed operating value for the fan motor impeller override active and the UV UV1and UV2 override active It i...

Страница 16: ...he IP address given to your computer In Subnet mask enter 255 255 255 0 Click OK Connect the computer to the PLC at the rear of the machine using a standard RJ45 Ethernet cable a category 5 straight c...

Страница 17: ...components in case of failure under a maintenance contract Please contact us directly for further information Before any operation it is essential to switch off the appliance see procedure on paragra...

Страница 18: ...F8 filters Replace them with new filters in the spaces provided for this purpose in the following filtration order G4 first then F8 second Warning observe the airflow direction indicated on the F8 fi...

Страница 19: ...Pinit Pfinal REPLACEMENT FREQUENCY QUANTITY mm Pa Pa R4000 G4 filter G4 R4000 592 592 48 105 250 3 to 6 months 1 F8 filter F8 R4000 595 595 97 160 450 6 to 12 months 1 Adsorbent filter CA R4000 592 5...

Страница 20: ...erate the appliance with damaged or torn filters Do not operate the appliance with the circuit breaker short circuited risk of high UV irradiation Do not open the electrical cabinet if you do not have...

Страница 21: ...ing no catalytic treatment and risk of permanent deactivation of the catalyst the fan is not rotating CALISTAIR accepts no responsibility and guarantee in case of failure to comply with the instructio...

Отзывы: