The installation of cables in the boat must conform with the relevant valid
specifications of the Association of German Electrotechnical Engineers (VDE)
as well as the regulations of German Lloyd.
230 Volt input
Cross cable section: 2.5 mm² Connect the cable without
wire terminating sleeves to the cage tension spring
clamp. L1 to terminal 1, N to terminal 2, green/yellow =
PE conductor.
230 Volt boiler
output
Cross cable section: 2.5 mm² Connect the cable without
wire terminating sleeves to the cage tension spring
clamp. L1 to terminal 3, N to terminal 4, green/yellow =
PE conductor.
230 Volt
distribution
output
Cross cable section: 2.5 mm² Connect the cable without
wire terminating sleeves to the cage tension spring
clamp. L1 to terminal 5, N to terminal 6, green/yellow =
PE conductor.
Check that all the connections are firm and secure.
Maintenance instructions
(
&
) '
'
The device is maintenance-free. Clean the device with a dry, lint-free cloth.