31
Operating instructions
Electric-System EVS 34/12-DS/IU
CALIRA
Electronic GmbH & Co. KG
Lerchenfeldstr. 9 87600 Kaufbeuren
Tel.+49(0)8341/9764-0 Fax +49(0)8341/67806
Internet: http://www.calira.de
Email: [email protected]
Technical data
Alternating current, 215 V - 245 V/50 Hz, single phase
DC 10 - 15 V from battery I
Charging current for battery II, maximum 12 A, arithmetic
average, electronically regulated according to the IUoU
characteristic charging curve.
Charging current for battery II, maximum 7 A
12V DC
Output battery II, regulated DC, 14.2 V.
Refrigerator output, 12 V from battery I
Automatic
Main charging ON at battery voltage 13.5 V
Main charging OFF at battery voltage 14.4 V
Timer six hours constant 14.4 V
Holding charge, constant at 13.8 V
ON when voltage is present at contact 10
Parallel operation, buffer operation, general charging
operation
Ambient temperature of -25°C to +35°C. During oper-
ation, the housing may heat up to approx. 70°C.
By convection
Power supply
Mains operation:
Driving operation:
Output current
Mains operation:
Driving operation:
Output voltage
Mains operation:
Driving operation:
Charging process:
Automatic switch.:
Mains operation:
Temperaturede-
The values of the automatic switching refer to a battery
pendent control
temperature of 20° C. When using a temperature sensor
at the supply battery, these values vary as a function of
the battery temperature.
High temperature ==> lowering of the threshold values.
Low temperature ==> higher threshold values.
Driving operation:
Application:
Temperature:
Cooling:
(optional)