Lerchenfeldstr. 9 87600 Kaufbeuren Tél.: +49 (0)8341 9764-0 Fax: +49 (0)8341 67806
5
Battery monitor Accucare BW 35
Intermediate switching device for automatic switch-off of consumers to protect
the 12Volt battery from total discharge and sensitive devices from under-
voltage. Should be connected between the battery and the consumer (mains
supply).
Technical data
Housing:
Plastic, black
Dimensions/weight:
L 98mm x W 88mm x H 44mm, 140g
Operating voltage:
10 – 15Volt
Switched current:
35Ampere max. (with bistable relay)
Current input:
1.8mA from the battery for the electronics (load
switched off)
Switching thresholds: Off at 10.8Volt (3min delay)
Equipment:
“EMERGENCY ON” button for short-term (3min)
bridging of the automatic switch-off device for emer-
gency situations at voltages below 10.8Volt. Connec-
tion options for extern “EMERGENCY ON” button.
Connections:
Terminal blocks for inputs and outputs
Scope of supply:
Accucare BW 35, connection diagram with operating
instructions, items packed separately
Warranty
The warranty is in force for a period of two years from date of purchase.
Defects arising from material or manufacturing faults will be rectified free of
charge, provided that:
The device is sent to the manufacturer postage paid.
Proof of purchase is enclosed.
The device has been handled and used according to its specified purpose.
No foreign spare parts were installed and the device has not been
interfered with.
Consequential costs and normal wear and tear are excluded.
Important
Claims made under warranty should be accompanied by a detailed description
of the fault. This facilitates and expedites the processing. Please bear in mind
that we cannot accept items sent without the correct postage having been paid.