9610_ii_150901
Pg 2
2
MOUNTING CONTROLLER
Important:
Determine location of CONTROLLER
(4)
. The
location should be near the electrical OUTLET
(7)
and DISPOSAL
CORD
(8a)
Mount CONTROLLER
(4)
to side or back wall
under sink with two SCREWS
(5)
(not supplied)
Slide TUBE
(6)
onto air switch OUTLET
(1d)
and
the other end to controller INLET
(4a)
Insert CONTROLLER CORD
(4b)
into ground-
fault current interrupter (GFCI) OUTLET
(7)
Warning:
When DISPOSAL CORD
(8a)
is plugged into
CONTROLLER OUTLET
(4c)
the DISPOSAL
(8)
may turn on; to
turn off DISPOSAL
(8)
press AIR SWITCH
(1)
Insert DISPOSAL
CORD
(8a)
into one of the two
CONTROLLER OUTLET
(4c)
NOTE:
The other CONTROLLER OUTLET
(4d)
may be used for
other device (e.g. instant hot water tank); DO NOT use for
dishwasher as this outlet switches OFF when DISPOSAL
(8)
is in use
GROUND-FAULT
CURRENT INTERRUPTER
(GFCI) 15A MIN
Push for ON / OFF
DO NOT use
second outlet for
DISHWASHER plug
(see NOTE above)
californiafaucets.com
5271 Argosy Ave. Huntington Beach, CA 92649 800-822-8855