background image

10

Customer Support: 1-866-409-4581

AIR COMPRESSOR

electrical power

electrical power requirements

before using the air compressor, refer to the serial label for

voltage and amperage requirements. Make sure you have a

sufficient electrical supply for supporting the motor's

requirements. 
use a dedicated circuit for the best results.
Low voltage and/or an overload circuit can cause the motor's

overload protection system circuit breaker to trip.

electrical extension cords

Inspect all electrical extension cords to ensure that they are

free of damage.
When using an extension cord, use a heavy-duty cord that is

no more than 25 feet long and at least 14 gauge.
use only a 3-wire extension cord that has a 3-blade grounding

plug.  

OPeRATINg The AIR

COMPReSSOR

Save this manual for future reference.

Introduction

This air compressor features a compact structure, stable

performance, a high airflow rate, and easy operation and

maintenance. because the air compressor produces no oil in

the airflow, it can be used as an independent air supply

machine for situations in which oil in the airflow is an issue. 
The motor directly drives the eccentric wheel-connecting bar

system, making the piston move reciprocally. The piston is

made from a high-temperature-resistant and abrasion-resistant

nonmetallic material, and is able to function without lubrication

for a long time.

assembly

1.

Connect your air supply hose to a 14” male universal or

industrial quick connect coupler.Connect the male quick

connect coupler to the female quick connect coupler located

on the air compressor.

2.

Make sure the drainage valve is off and that the pressure

switch is in the OFF position.

3.

ensure that the power supply you are going to use is operating

normally.

4.

Insert the power supply cord into the power supply socket.

DANGER

There is a danger of electric shock.

Use only undamaged electrical cords.

DO NOT touch bare wires or receptacles.

DO NOT operate air compressor in wet weather or in 
wet conditions.

DO NOT touch air compressor or cords if hands or 
feet are wet.

Ensure that all cords are free of damage before 
connecting to the power supply.

Ensure that you have a sufficient electrical supply for 
supporting the requirements of the motor.

SHOCK

Use caution when using extension cords.

Use an extension cord which is no more than 
25 feet long and at least 14 gauge.

Using an excessively long or thin-wired extension 
cord will cause severe damage to the motor.

Use only a 3-wire extension cord that has a 3-blade 
grounding plug.

CAUTION

Содержание Industrial 6010LFC

Страница 1: ...ULTRA QUIET OIL FREE AIR COMPRESSOR OwnER S MAnUAL IndUSTRIAL SERIES 6010LFC 1 0 HP 4 00 CFM 40 PSI 3 00 CFM 90 PSI 6 0 Gallon Steel Tank WWW CALIFORNIAAIRTOOLS COM Customer Support 1 866 409 4581 ...

Страница 2: ..._________________12 draining the air tank ___________________________12 changing the air filter__________________________12 testing for Leaks ______________________________12 pressure Switch _______________________________12 cleaning _____________________________________12 Storage______________________________________12 troubLeShootIng ____________________________13 SpecIfIcatIonS_________________...

Страница 3: ...r compressor do not return your air compressor for service or parts to the store dealer where purchased IMPORTANT SAFeTy INSTRuCTIONS Safety messages Signal Words DANGER Moving parts can cause severe trauma Keep hands and feet away from rotating parts tie up long hair remove jewelry and DO NOT wear loose clothing KICKBACK DANGER There is a danger of electric shock Use only undamaged electrical cor...

Страница 4: ... the air compressor after it has thoroughly cooled down FIRE HOT SURFACE WARNING Flying objects can cause injury to the eyes head and other parts of the body Air powered equipment and power tools are capable of propelling items metal chips fasteners and particulates at high speed into the air and could result in injury Always wear approved head and eye protection Never point the air stream at any ...

Страница 5: ...f extreme heat do not use plastic pipe or lead tin solder joints for a discharge line WARNING EXPLOSION Use caution to minimize risk of fire or explosion It is normal for the air compressor motor and pressure switch to produce sparks while operating If sparks come in contact with vapors from gasoline or solvents they may ignite and cause a fire or explosion Abrasive tools such as grinders drills a...

Страница 6: ...se labels provide important safety and maintenance information These labels should be considered as permanent parts of the air compressor Should any of these labels become illegible damaged or removed please contact California Air Tools Customer Service department at 1 866 409 4581 for replacements PROduCT LAbeL a b c d e f g h ...

Страница 7: ...7 Customer Support 1 866 409 4581 AIR COMPRESSOR ...

Страница 8: ... the air compressor Screw the air filter into motor head port that is located under the Plastic head Cover Install the Wheel kit 1 Slide Washer 59 through bolt 58 2 Slide bolt 58 through Wheel 60 Slide the bolt and Wheel through the wheel support hole located on the back bottom of the air compressor tank 3 Attached the Washer 56 and Nut 57to the bolt 58 and tighten firmly 4 Repeat steps 1 3 to ass...

Страница 9: ...t or particulates are in the air This will damage the motor and impair proper operation Important Always use the air filter properly installed Use caution to minimize risk of fire or explosion It is normal for the air compressor motor and pressure switch to produce sparks while operating If sparks come in contact with vapors from gasoline or solvents they may ignite and cause a fire or explosion A...

Страница 10: ...bar system making the piston move reciprocally The piston is made from a high temperature resistant and abrasion resistant nonmetallic material and is able to function without lubrication for a long time assembly 1 Connect your air supply hose to a 14 male universal or industrial quick connect coupler Connect the male quick connect coupler to the female quick connect coupler located on the air com...

Страница 11: ...o not touch the air compressor s cylinder head During operation the cooling fins of the cylinder head and delivery pipe become hot Allow the air compressor to cool before touching it DO NOT place a storage cover on the unit during operation Only place a cover on the air compressor after it has thoroughly cooled down FIRE HOT SURFACE WARNING Flying objects can cause injury to the eyes head and othe...

Страница 12: ...he air filter then remove the air filter element 2 To clean the element blow off or brush off the dirt and dust 3 If clogged replace with a new air filter testing for Leaks Make sure all connections are tight do not overtighten A small leak in any hose or pipe connection will reduce the air compressor s performance To test for small leaks spray a small amount of soapy water on the area suspected o...

Страница 13: ...indings are burned out Contact Customer Support The motor does not start and makes a humming noise Capacitor is burned out Replace starter capacitor The motor does not start or starts slowly Low voltage supply to the motor Check that the main voltage corresponds to the air compressor specifications An extension cord that is too thin or too long can cause a voltage drop use heavy duty extension cor...

Страница 14: ...arth wire Green Red cords for Capacitor Electric cord for motor Solenoid valve Electric cord for motor Pressure switch Overload protector MAX temperature 135 C Pressure switch Safety valve Pressure gauge Regulator Pressure gauge Ball valve Filter Drain valve Air intake Check valve Solenoid valve Compressor Tank ...

Страница 15: ...fic legal rights and you may also have other rights which may vary from state to state disclaimer of other Warranties To the fullest extent permitted by applicable law this limited warranty is exclusive and expressly in lieu of any and all other warranties including without limitation any implied warranties of merchantability or fitness for a particular purpose or any other implied warranties that...

Страница 16: ...ded by California Air Tools Inc 9 Acts of god The application of these exclusions will be determined at the sole discretion of California Air Tools Inc registration Warranty registration with California Air Tools Inc is required on all products you can mail the enclosed registration form or register on line how to Videos California Air Tools provides hOW TO VIdeOS on our website WWW CALIFORNIAAIRT...

Страница 17: ...ation date of Purchase _____________________________________________________________ MM dd yyyy Model Number ______________________________________________________________________________ Serial Number ___________________________________________________________ Found on name plate Purchased Location __________________________________________________________________________ Purchase Price _________...

Отзывы: