12
PRESSURE TESTING AND HOOKUPS
CAUTION!
Use grill only as it is built onto the included base cart. DO NOT build grill into a combustible enclosure.
PRESSURE TESTING
»
The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure test-
ing of that system, at test pressures in excess of 1/2 PSIG (3.5 kPa).
»
The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any
pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 PSIG (3.5 kPa).
LOCAL CODES
»
The installation of this appliance must conform to local codes. In the absence of local codes refer to the National Fuel gas Code,
ANSI Z223.1a-1998.
»
Installation in Canada must be in accordance with the Standard Can1-b149.1 and/or .2 (installation for gas burning appliance
and equipment) and local codes.
NATURAL GAS HOOK-UP
»
Natural gas: manifold connection 1/2” NPT male with 1/2” coupling.
»
Operating Pressure: 4.0 WC Supply pressure 5” to 14” W.C.
»
If in excess of 14” WC, a step down regulator is required.
»
Check with your local gas utility or with local codes for instructions or for installing gas supply lines.
FITTINGS SUPPLIED WITH GRILL
»
To hook up the fittings supplied with grill, use threading compound on male thread only. Do not use threading compound on
the male end of 1/2” NPT to 3/8” flare adaptor. Use second pipe wrench to hold the grill inlet pipe to avoid shifting any internal
gas lines of the grill. Ensure that the regulator arrow points in the direction of the gas flow towards the unit. AWAY from the sup-
ply. Do not forget to place the installer supplied gas shut-off valve in an accessible location.
PARTS SUPPLIED WITH UNIT
»
(1) Nat Gas Regulator
»
(2) 1/2” NPT Nipple
»
not used with natural gas 1/2 coupler should be supplied also a 82108
LP GAS HOOK-UP
»
Never connect an unregulated gas line to the grill. The LP tank is NOT included. If the unit is to be hard-piped to an external LP
supply, contact your local gas utility company for instructions in installing this appliance.
»
Operating pressure: 10” WC
»
To avoid heat degradation (loss of heat) keep the supply as short as possible
LP TANKS
»
A dented or rusty LP tank may be hazardous and should be checked by your LP cylinder supplier. Never use a cylinder with a
damaged valve.
»
The LP gas cylinder must be constructed and marked in accordance with the specifications for LP gas Cylinders of the US de-
partment of Transportation (DOT).
»
The cylinder must be provided with a shut-off valve terminating in an LP gas supply cylinder valve outlet specified, as
applicable, for connection type QCC-1 in the standard for compressed gas cylinder valve outlet and inlet connection
ANSI/CGA-V-1.
NOTE: The LP Tank is NOT INCLUDED with the grill and must be purchased separately from your local LP cylinder supplier.
Содержание Rockwell CRG42SS-L