Page 14
March 2022 Version 1.0
www.binsense.com
nothing is detected on the sensor cable interface, the LED will flash one red flash followed by a long pause, and
then six red flashes for the radio channel.
EXAMPLE:
If you have one eight-sensor temperature cable, and one eight-sensor moisture cable connected to a Master
unit that is set to radio channel 22, you would expect the following flashing pattern:
•
One
red flash (for total temperature & moisture cables) followed by two green flashes (for number of
cables).
•
Two
red flashes (for the total number of sensors) followed by one orange flash (for 10) and six green
flashes (for a total value of 16).
•
Three
red flashes (for the number of moisture sensors) followed by eight green flashes (for eight).
•
Six
red flashes (for the radio channel) followed by two orange flashes (for 20) and 2 green flashes (for a
total value of 22).