Calian IntraGrain Bin-Sense Скачать руководство пользователя страница 13

www.binsense.com

March 2022 Version 1.0

Page 11

OPERATION

CONNECTING TO A MASTER UNIT

Remote units connect wirelessly to a Bin-Sense Master unit using a 

radio system similar to Wi-Fi. In order to connect to a Master unit, 

the Remote unit must be associated though the Bin-Sense Live 

website and must be on the same radio channel. Associations 

must be performed by authorized Bin-Sense dealers.

The radio channel is set using the radio channel DIP switches. 

Channels 12 through 23 are available with the default channel 

being 23. The radio channel only needs to be changed if there are other Bin-Sense Live systems installed nearby 

(within roughly 2 km).

To set the radio channel, use a small flat screwdriver to change the individual switches to match the pattern of 

the desired channel as shown below. The transparent yellow film covering the switches can be removed with 

tweezers or you can push through it with the screwdriver.

More details about connecting to the Master unit can be found in the Bin-Sense Live Startup Manual.

Figure 3:  DIP Switches

Figure 4:  DIP Switch Settings

Содержание IntraGrain Bin-Sense

Страница 1: ...700052 BS March 2022 Version 1 0 REMOTE UNIT USER MANUAL...

Страница 2: ...700052 BS March 2022 Version 1 0 INTENTIONALLY BLANK...

Страница 3: ...CERTIFICATIONS 4 MANUFACTURER S WARRANTY 5 HOW TO OBTAIN WARRANTY SERVICE 5 SAFETY 6 STANDARDS 6 OVERVIEW OVERVIEW 7 PACKAGE CONTENTS 7 REMOTE UNIT OVERVIEW 7 INSIDE THE REMOTE UNIT 8 INSTALLATION IN...

Страница 4: ...Page 2 March 2022 Version 1 0 www binsense com DIAGNOSTICS LED DIAGNOSTICS 13 Led Flash Sequence 13...

Страница 5: ...vice please contact your local dealer For product support troubleshooting or additional questions with your Bin Sense device please contact your local dealer www binsense com locate a dealer or IntraG...

Страница 6: ...ference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction...

Страница 7: ...R This warranty does not cover normal wear of parts or any damage resulting from any of the following negligent use or misuse of the product damage in transport natural disaster improper installation...

Страница 8: ...recommended by the manufacturer STANDARDS This manual will use the following standard safety terms and conventions to indicate conditions WARNING INDICATES A HAZARDOUS SITUATION RESULTING IN SERIOUS I...

Страница 9: ...grain temperature and moisture data for a single bin on a Bin Sense Live site The Master unit collects data from all the Remote units on a site then sends that data to the Bin Sense website through a...

Страница 10: ...IDE THE REMOTE UNIT A PRIMARY MASTER ANTENNA B DIAGNOSTIC PUSHBUTTON C DIAGNOSTIC LED D J2 SPARE SENSOR CABLE CONNECTION E J1 SENSOR CABLE CONNECTION F J11 SOLAR PANEL CONNECTION G VENT H RADIO CHANNE...

Страница 11: ...he installation make sure the enclosure lid is closed and latched securely and there are no wires tags or other objects caught between the lid and the enclosure which could cause water ingress REMOTE...

Страница 12: ...Page 10 March 2022 Version 1 0 www binsense com 8 Refer to the Bin Sense Live Startup Manual for further instruction on how to get the Bin Sense Live system up and running...

Страница 13: ...nnel DIP switches Channels 12 through 23 are available with the default channel being 23 The radio channel only needs to be changed if there are other Bin Sense Live systems installed nearby within ro...

Страница 14: ...Page 12 March 2022 Version 1 0 www binsense com INTENTIONALLY BLANK...

Страница 15: ...ing pattern will continue to repeat skipping the channel number until the Remote unit connects to a Master unit The diagnostic LED flashes different colors to convey different information Red flashes...

Страница 16: ...t is set to radio channel 22 you would expect the following flashing pattern One red flash for total temperature moisture cables followed by two green flashes for number of cables Two red flashes for...

Страница 17: ...Manufactured in Canada by Head Office IntraGrain Technologies Inc 118 Husum Road RM of Sherwood SK CANADA S4K 0A4 support intragrain com 1 833 570 7979 www binsense com...

Отзывы: