ALS
500T-SWM-TB
INSTALLATION INSTRUCTIONS
Design Guidelines (Configurations)
LINEAR CONFIGURATION
8’
8’
3’6”
19’6”
End Cap
C
Standard Length
A
Custom Length
B
MITERED CONFIGURATION
8’
18-3/16”
18-3/16”
1’
1’
6’
8’
Standard Length
A
Custom Length
B
Mitered Corner
D
Mitered Corner
D
End Cap
C
JUMPER CONFIGURATION
8’
8’
Jumper Cable
E
Standard Length
A
End Cap
C
POWER DISTRIBUTION
Continuous Connection
G
Driver
F
Driver
F
To Power Source
To Power Source
Circuit #2
H
(White)
Circuit #1
H
(Gray)
KEY
A
Standard Length:
Luminaire runs are constructed in 8’ segments.
B
Custom Length:
Any required length that is not 8’. Typically the last
segment of a run.
C
End Cap:
Used to terminate a run.
D
Mitered Corner:
Standard 90° Mitered Corner. Custom angles available
upon request.
E
Jumper Cable:
Used to connect two luminaires with a gap between.
F
Driver:
The driver is typically mounted on top of the first luminaire
segment of a run. The driver may also be mounted elsewhere. Each run
typically has its own driver.
G
Continuous Connection:
Each luminaire segment is built with quick
disconnects to easily connect to the next segment in line.
H
Circuits:
Example U-Shaped run exceeds Max Run lengths and is split
into two circuits, each with their own driver. Max Run lengths vary by light
source. See light source specifications for details.