CALI alumLEDs ALS500T-SWM-FG Скачать руководство пользователя страница 20

CALIFORNIA ACCENT LIGHTING, INC.

2820 E. Gretta Lane, Anaheim, CA 92806
ph. 800.921.CALI (2254) | fx. 714.535.7902 | [email protected] | calilighting.com

© CALI. All rights reserved. CALI reserves the right to make changes or withdraw specifications without prior notice.

4 / 2 / 2022 / Rev 4

Page 20 of 20

ALS

500T-SWM-FG

INSTALLATION INSTRUCTIONS

Troubleshooting & Continuity Test

Damaged LED

Poor Quality Cut

Damaged Connection

Broken Solder Connection

Foreign Object

Metal Flakes

Damaged Board

1. 

Turn off power before beginning. Check for any damage to the circuit in the LED board.

      If there is excessive damage and the circuit is broken, the board must be replaced.

3. 

Check to make sure cuts in the board are clean. Poor quality cuts to the LED board will

       cause damage to the circuit, resulting in dim, flickering, or lightless LEDs.

4. 

Check connections between LED terminals and, if applicable, check soldered connections.

2. 

Check for metal particles or other foreign objects causing the short.

TROUBLESHOOTING TIPS

• Do not reset the breaker multiple times
• If the unit is overloaded, the breaker will trip, shutting off the transformer and lights
• If the breaker reset button has been held down by hand or any type of pressure, such as duct
   tape, or if the breaker has been reset multiple times without troubleshooting, the unit will:
   - Burn the transformer bobbin
   - Burn the thermal or magnetic breaker
   - Burn the primary or secondary wires due to high amperage caused by overload
   - Short circuit in line which will not allow the breaker to reset
   - Damage the lighting

1. 

Turn power off before beginning. Verify power is turned off by using a non-contact circuit

      tester. Touch the probe of the tester to positive wire of the power source. The tester will
      light up if an electrical current is detected.

3. 

Verify that your tester is functional by touching probes together. The tester should light up,

       beep, or read 0Ω (ohms) of resistance.

4. 

Touch the red probe to the positive (+) wire and the black probe to the negative (-) wire.

       If a conductive path is formed between the positive and negative wires, the multimeter will
       beep, flash, or read 

 (ohms). Troubleshoot to identify the malfunction in the line.

       If there is no conductive path, the multimeter will not show any feedback.

5. 

Touch the red probe to the fixture extrusion and the black probe to the positive (+) wire.

       If a conductive path is formed between the extrusion and the positive wire, the multimeter
       will beep, flash, or read 

 (ohms). Troubleshoot to identify the malfunction in the line.

       If there is no conductive path, the multimeter will not show any feedback.

6. 

Touch the red probe to the fixture extrusion and the black probe to the negative (-) wire.

       If a conductive path is formed between the extrusion and the negative wire, the multimeter
       will beep, flash, or read 

 (ohms). Troubleshoot to identify the malfunction in the line.

       If there is no conductive path, the multimeter will not show any feedback.

7. 

Set voltmeter to DC voltage and test power source. Confirm the correct voltage before

      connecting lighting to power source. If voltage reading is more than 1 volt higher than the
      marked output voltage, there is a problem with the power source or driver.

8. 

Connect power connector to power source. If LEDs do not turn on, flip polarity (+ -) or

       power source connection to power connector.

 CONTINUITY  TEST

A continuity test is performed to determine if electricity can pass through two points on 
an electrical circuit. This helps identify shorts or malfunctions in the line or fixture. Use a 
multimeter or continuity tester to perform the steps below. 
• Always perform a continuity test before connecting lighting to power source. 
• Malfunctions are not always as obvious as the lights not turning on. 
• A short or malfunction in the line or fixture will cause damage over time, ultimately damaging
   the lighting and voiding warranty.

(-)

(+)

Red Probe

Black Probe

LED Lighting

(-)

(+)

Black Probe

LED Lighting

Red Probe

(-)

(+)

Black Probe

LED Lighting

Red Probe

2. 

Setup your tester. First insert the black probe lead into the COM jack, then insert the red

       probe lead into the VΩ jack.

1

2

Содержание alumLEDs ALS500T-SWM-FG

Страница 1: ...urface material can support the weight of the luminaire ELECTRICAL INSTALLATION RECOMMENDATIONS INSTALLATION TOOL REQUIRED ALS500T SWM requires a remote driver The driver may be mounted on top of the...

Страница 2: ...tory for any malfunctions Do not attempt to repair Only use alumLEDs with specified rated voltages Do not exceed the specified voltage for any alumLEDs luminaire Do not use alumLEDs extrusion as a rac...

Страница 3: ...rce To Power Source Circuit 2H White Circuit 1H Gray KEY A Standard Length Luminaire runs are constructed in 8 segments B Custom Length Any required length that is not 8 Typically the last segment of...

Страница 4: ...anges or withdraw specifications without prior notice 4 2 2022 Rev 4 Page 4 of 20 ALS500T SWM FG INSTALLATION INSTRUCTIONS Diagram of Assembly Wall Trim Mounting Bracket Assembly 5 8 Drywall 1 8 Mud W...

Страница 5: ...Mounting Brackets required Note Refer to the diagrams on page 16 as a guide 5 If applicable assemble Mounting Brackets Insert Hex Head Bolts through holes then place Lock Washer and Hex Nut on bolts L...

Страница 6: ...hex nuts 11 Make wiring connections from driver to 1st PCB Pull lead wires from luminaire and make splice connections to lead wires from driver Verify wiring diagram before connecting 13 Verify driver...

Страница 7: ...ior notice 4 2 2022 Rev 4 Page 7 of 20 ALS500T SWM FG INSTALLATION INSTRUCTIONS Diagram of Assembly Hanging Bracket Assembly Reflective Film 5 8 Drywall Wall Stud Wall Trim Lens Trim Retention Spring...

Страница 8: ...bit for surface and screw size Each rail must be mounted with a minimum of two screws Drill additional holes in Rail Brackets if necessary Note Use 8 32 x 2 Countersink Screw By others 7 Install Hang...

Страница 9: ...y wiring diagram before connecting 16 Verify driver wire colors from wiring diagram then connect luminaires to power source Drivers used for this product vary Always confirm wiring diagram from driver...

Страница 10: ...r withdraw specifications without prior notice 4 2 2022 Rev 4 Page 10 of 20 ALS500T SWM FG INSTALLATION INSTRUCTIONS Diagram of Assembly Aircraft Cable Assembly 5 8 Drywall 1 8 Mud Wall Stud Wall Trim...

Страница 11: ...ontinuous edge around grid for the Ceiling Trim to rest on Hang the center of the T Bar 6 1 8 away from wall stud 2 Hang or cut drywall along installation area so it is exactly 4 above ceiling line No...

Страница 12: ...ys install corners first 10 If applicable install end cap to end of run 11 After all luminaires have been mounted secure Aircraft Cable Assemblies to luminaire by tightening lower hex nuts All aircraf...

Страница 13: ...olors from wiring diagram then connect luminaires to power source Drivers used for this product vary Always confirm wiring diagram from driver installation instructions before connecting 19 After all...

Страница 14: ...t Rail Bracket ALS500T SWM 6 8 Hanging Bracket Rail Bracket For luminaires 1 long use 1 Rail Bracket and 2 Hanging Brackets Install 2 Hanging Brackets 2 from each end of 1 Rail Bracket Align the 1 Rai...

Страница 15: ...5 Aircraft Cable Assembly 4 ALS500T SWM 6 8 Aircraft Cable Assembly 4 For luminaires 1 5 long use 2 Aircraft Cable Assemblies per luminaire Install each assembly about 4 from each end of luminaire No...

Страница 16: ...0T SWM 1 5 4 Mounting Bracket Wall Trim ALS500T SWM 6 8 4 Mounting Bracket Wall Trim For luminaires 1 5 long use 2 Mounting Brackets per luminaire Install each bracket about 4 from each end of luminai...

Страница 17: ...blade for cutting metal Note If applicable remove Connector Blocks from extrusion before cutting 1 Position luminaires together and align the screw of the Male Block to meet the Female Block Tighten A...

Страница 18: ...n trim and fixtures not aligned Install Trim Retention Springs to ceiling trim Use one clip per 2 or two clips per segment under 4 Install clips 4 from each edge evenly spaced 3 Measure and cut a 2 se...

Страница 19: ...rmula 409 FEATURES MAINTENANCE SPECIFICATIONS REFLECTANCE 550NM 97 5 0 8 ASTM E1164 L VALUE 98 9 ASTM E308 A VALUE 0 35 0 25 ASTM E308 B VALUE 0 90 0 30 ASTM E308 GLOSS 60 5 0 ASTM D2456 THICKNESS 205...

Страница 20: ...e positive wire and the black probe to the negative wire If a conductive path is formed between the positive and negative wires the multimeter will beep flash or read 0 ohms Troubleshoot to identify t...

Отзывы: