Calex PMB201 Скачать руководство пользователя страница 2

2

PyroMiniBus non-contact infrared sensors measure temperatures from -20°C to 1000°C and 

provide an RS485 Modbus RTU interface.
The sensors are capable of being used in ambient temperatures up to 120°C without cooling 

(XCF models: 70°C). They may be connected directly to third-party Modbus Masters, and they 

are compatible with the optional PM180 6-channel touch screen interface, which provides 

temperature display, data logging, alarms and analogue outputs.
A 6-channel junction box (model PMBHUB) is available to easily connect PyroMiniBus sensors 

to the PM180 as a complete temperature measurement system.

SENSOR SPECIFICATIONS

Model Numbers

Field of View

Model Number

2:1

PMB21

20:1

PMB201

Close Focus (Ø3.5 mm at distance 50 mm)

PMBXCF

General

Interface

RS485 Modbus RTU

Accuracy

±1% of reading or ±1°C whichever is greater

Repeatability

± 0.5% of reading or ± 0.5°C whichever is greater

Emissivity

0.2 to 1.0

Response Time

125 ms (90% response)

Spectral Range

8 to 14 μm

Supply Voltage

24 V DC (minimum sensor voltage 6 V DC, maximum 28 V DC)

Supply Current

50 mA max.

Baud Rate

9600 baud *

Format

8 data bits, no parity, 1 stop bit *

Mechanical

Construction

Stainless Steel

Dimensions

18 mm diameter x 45 mm long (excluding cable gland)

Thread Mounting

M16 x 1 mm pitch

Cable Length

1 m standard, longer cable available to order

Weight with 1 m Cable

85 g

Environmental

Environmental Rating

IP65

Ambient Temperature

0°C to 120°C (XCF models: 70°C)

Relative Humidity

95% max. non-condensing

* Other configurations available upon request

Содержание PMB201

Страница 1: ...PyroMiniBus Series Operator s Guide...

Страница 2: ...odel Number 2 1 PMB21 20 1 PMB201 Close Focus 3 5 mm at distance 50 mm PMBXCF General Interface RS485 Modbus RTU Accuracy 1 of reading or 1 C whichever is greater Repeatability 0 5 of reading or 0 5 C...

Страница 3: ...e the nominal target spot diameter at any given distance from the sensing head and assume 90 energy Sensors may be used at longer distances than these diagrams show Thread M16 x 1 mm Standard length 1...

Страница 4: ...aller than the target We normally recommend that the target should be at least twice the size of the measured spot for maximum accuracy AMBIENT TEMPERATURE The sensor is designed to operate in ambient...

Страница 5: ...ckets or cut outs of your own design or you can use the fixed and adjustable mounting bracket accessories which are shown below Note The sensor must be grounded at only one point either the cable shie...

Страница 6: ...nterface please see the PM180 section of this Operator s Guide IMPORTANT Do not connect or disconnect Modbus devices with power on Always disconnect power before modifying electrical connections SENSO...

Страница 7: ...seconds R W 0x0B 1 Average Temperature R 0x0C 1 Minimum Temperature R 0x0D 1 Maximum Temperature R 0x0E 1 Filtered Temperature R 0x0F 1 Unfiltered Temperature R 0x10 1 Sensor Temperature R 0x11 1 Sta...

Страница 8: ...ng Averaging and Hold Processing Unfiltered Temperature The raw measured temperature without Averaging or Hold Processing Sensor Temperature The temperature inside the sensor body this is usually a fe...

Страница 9: ...etween moving objects e g on a conveyor or by an obstruction LENS CLEANING Keep the lens clean at all times Any foreign matter on the lens would affect measurement accuracy Blow off loose particles if...

Страница 10: ...loves on With an optional MicroSD Card inserted the PM180 functions as a fully configurable data logger SPECIFICATIONS Touch Screen Display 2 83 72 mm resistive TFT 320 x 240 pixels backlit Supply Vol...

Страница 11: ...termined time via the Settings menu If the PM180 is connected via the slave interface to another Modbus network logging may also be started remotely by the Modbus Master on that network DIMENSIONS PMB...

Страница 12: ...12 ELECTRICAL CONNECTION...

Страница 13: ...PM180 is locked and the Settings menu is greyed out To access the Settings menu unlock the PM180 The default password is 1234 After entering the password tap the Unlock icon to unlock the unit The pa...

Страница 14: ...0 to 59 R W 0x0012 1 Data acquisition start time Day 1 to 31 R W 0x0013 1 Data acquisition start time Month 1 to 12 R W 0x0014 1 Data acquisition start time Year 2012 to 2105 R W 0x0015 1 Alarm log se...

Страница 15: ...20 5 0x1500 5376 Example To read the Filtered Temperature on a PyroMiniBus sensor in position 4 on the PM180 as shown above read from register 0x0E 0x1400 0x140E decimal 5134 For information on the Mo...

Страница 16: ...Calex Electronics Limited PO Box 2 Leighton Buzzard Bedfordshire England LU7 4AZ Tel 44 0 1525 373178 Fax 44 0 1525 851319 Email mail calex co uk Online www calex co uk Issue E Jul 2018...

Отзывы: