MODBUS OVER SERIAL LINE (RS485)

INTERFACE

SUPPORTED FUNCTIONS

Baud rate

9600

Read register

0x03, 0x04

Format

8 data, No parity, 1 stop

Write single register

0x06

Reply delay (ms) 20

Write multiple register

0x10

The list below includes all available addresses (R = Read, W = Write):

Address

Length 

(words)

Description

R/W

0x0000

1

MODBUS slave ID (slave address) of PM180

R/W

0x0001

7

Device identification string in ASCII

R

"PM180vx.xx" where x.xx is the firmware version

0x0008

2

Serial number

R

0x000A

2

Data acquisition sample interval (1 to 86400 seconds)

R/W

0x000C

2

Number of samples to be logged (0 to 86400 samples) - 

note: enter 0 to log continuously 

R/W

0x000E

1

Data acquisition enabled (0 for disabled, 1 for enabled)

R/W

0x000F

1

Data acquisition start time: Hours (0 to 23)

R/W

0x0010

1

Data acquisition start time: Minutes (0 to 59)

R/W

0x0011

1

Data acquisition start time: Seconds (0 to 59)

R/W

0x0012

1

Data acquisition start time: Day (1 to 31)

R/W

0x0013

1

Data acquisition start time: Month (1 to 12)

R/W

0x0014

1

Data acquisition start time: Year (2012 to 2105)

R/W

0x0015

1

Alarm log settings

R/W

Bit 0 - Log trigger time
Bit 1 - Log while triggered
Bit 2 - Log acknowledge time
Bit 3 - Log reset time

0x0020

1

Remote request - Start logging

R/W

Write 1 - request start of data logging
Read 1 - request pending, Read 0 - no request pending

0x0021

1

Remote request - Stop logging

R/W

Write 1 - request termination of data logging
Read 1 - request pending, Read 0 - no request pending

0x0022

1

Remote request - Acknowledge alarms

R/W

Write 1 - request acknowledgement of alarms
Read 1 - request pending, Read 0 - no request pending

0x0023

1

Remote request - Reset alarms

R/W

Write 1 - request reset of alarms
Read 1 - request pending, Read 0 - no request pending

NOTES:  

1  For further information please refer to http://www.modbus.org/specs.php
2  Use address 255 to communicate with any connected unit (only one sensor connected)
3  Use address 0 to broadcast to all connected units (no response expected)

Содержание PMB201

Страница 1: ...PyroMiniBus Series Operator s Guide...

Страница 2: ...odel Number 2 1 PMB21 20 1 PMB201 Close Focus 3 5 mm at distance 50 mm PMBXCF General Interface RS485 Modbus RTU Accuracy 1 of reading or 1 C whichever is greater Repeatability 0 5 of reading or 0 5 C...

Страница 3: ...e the nominal target spot diameter at any given distance from the sensing head and assume 90 energy Sensors may be used at longer distances than these diagrams show Thread M16 x 1 mm Standard length 1...

Страница 4: ...aller than the target We normally recommend that the target should be at least twice the size of the measured spot for maximum accuracy AMBIENT TEMPERATURE The sensor is designed to operate in ambient...

Страница 5: ...ckets or cut outs of your own design or you can use the fixed and adjustable mounting bracket accessories which are shown below Note The sensor must be grounded at only one point either the cable shie...

Страница 6: ...nterface please see the PM180 section of this Operator s Guide IMPORTANT Do not connect or disconnect Modbus devices with power on Always disconnect power before modifying electrical connections SENSO...

Страница 7: ...seconds R W 0x0B 1 Average Temperature R 0x0C 1 Minimum Temperature R 0x0D 1 Maximum Temperature R 0x0E 1 Filtered Temperature R 0x0F 1 Unfiltered Temperature R 0x10 1 Sensor Temperature R 0x11 1 Sta...

Страница 8: ...ng Averaging and Hold Processing Unfiltered Temperature The raw measured temperature without Averaging or Hold Processing Sensor Temperature The temperature inside the sensor body this is usually a fe...

Страница 9: ...etween moving objects e g on a conveyor or by an obstruction LENS CLEANING Keep the lens clean at all times Any foreign matter on the lens would affect measurement accuracy Blow off loose particles if...

Страница 10: ...loves on With an optional MicroSD Card inserted the PM180 functions as a fully configurable data logger SPECIFICATIONS Touch Screen Display 2 83 72 mm resistive TFT 320 x 240 pixels backlit Supply Vol...

Страница 11: ...termined time via the Settings menu If the PM180 is connected via the slave interface to another Modbus network logging may also be started remotely by the Modbus Master on that network DIMENSIONS PMB...

Страница 12: ...12 ELECTRICAL CONNECTION...

Страница 13: ...PM180 is locked and the Settings menu is greyed out To access the Settings menu unlock the PM180 The default password is 1234 After entering the password tap the Unlock icon to unlock the unit The pa...

Страница 14: ...0 to 59 R W 0x0012 1 Data acquisition start time Day 1 to 31 R W 0x0013 1 Data acquisition start time Month 1 to 12 R W 0x0014 1 Data acquisition start time Year 2012 to 2105 R W 0x0015 1 Alarm log se...

Страница 15: ...20 5 0x1500 5376 Example To read the Filtered Temperature on a PyroMiniBus sensor in position 4 on the PM180 as shown above read from register 0x0E 0x1400 0x140E decimal 5134 For information on the Mo...

Страница 16: ...Calex Electronics Limited PO Box 2 Leighton Buzzard Bedfordshire England LU7 4AZ Tel 44 0 1525 373178 Fax 44 0 1525 851319 Email mail calex co uk Online www calex co uk Issue E Jul 2018...

Отзывы: