COMFORT MODE 

 

“Comfort” mode maintains the room temperature at the value set. To set this mode: 
- Press the button 

[Prog]

 until the "Comfort" icon appears on the display. 

- Set the desired temperature with the 

[+] 

and 

[-]

 buttons and wait until the temperature on the display stops flashing. 

 

NIGHT MODE 

 

In “Night” mode, a temperature below the “Comfort”' temperature is set. 
It is advisable to use this mode during the night or when the room is not used for 2 hours or longer. 
- Press the button

 [Prog]

 until the "night" icon appears on the display. 

- Set the desired temperature with the 

[+] 

and 

[-]

 buttons and wait until the temperature on the display stops flashing. 

 

ANTIFREEZE MODE 

 

In “Antifreeze” mode, a temperature below the “Comfort”' temperature is set. 
It is advisable to use this mode during the night or when the room is not used for 2 hours or longer. 
- Press the button 

[Prog]

 until the "Anti-freeze" icon appears on the display. 

 

2H MODE 

 

The “2h Timer” mode can be used to warm up the room quickly or speed up the drying of towels. 
- Press the 

[Prog]

 

button until the “

2h

” icon appears on the display. 

The appliance is switched on at maximum power for 2 hours, up to a temperature of 32°C. 
The “2h timer” mode is set to stop automatically after a period of 2 hours and return to the previously set operating mode. 
If necessary, the user can return to other modes at any time by simply pressing the button

 [Prog]

 

FIL-PILOT MODE 

 

(For models equipped with “Fil-Pilot” connection only). 
In “Fil-Pilot mode” the device is controlled by a central system, which sets the operating mode for all the thermostats connected. The device also 
recognises the more advanced six-

order '”Fil-Pilot” system, which allows the use of the functions described below. 

1. 

Standby: 

switches off the heating element, thermostat stays on. 

2. 

Comfort

: maintains the "Comfort" temperature set by the user. 

3. 

Eco: 

maintains the ambient temperature 3.5°C below the "Comfort” temperature. 

4. 

Anti-freeze: 

maintains the ambient temperature at 7°C. 

5. 

Eco-1: 

maintains the ambient temperature 1°C below the "Comfort” temperature. 

6. 

Eco-2: 

maintains the ambient temperature 2°C below the "Comfort” temperature. 

To activate the "Fil-

Pilot” function: 

- Press the  button

 [Prog]

 until the "Fil-Pilot" mode icon appears on the display. 

- Set the desired temperature with the 

[+] 

and 

[-]

 

buttons and wait until the temperature on the display stops flashing. If the “Fil-Pilot” 

system is not installed, the system operates in “Comfort” mode. 

 

FIL-PILOT MODE ACTIVATION 

 

This operating mode allows the user to set different temperatures during 

the day. The “Comfort” / “Night” 

temperature and time intervals can be programmed. 
- To activate the function, press the 

[Prog]

 

button until the “Chrono” icon appears on the display. 

 

CHRONO MODE PROGRAMMING 

 

a) Set the current date and time 

- Activate the 

“Stand-by” mode and press the key for more than 3 seconds. 

The message will appear at the top of the display: “Set”. 

- To set the current date and time, press the [+] button until tEd (time and date) appears at the bottom of the display. 

_View picture 

 
 

- Press the button 

[Prog]

 to enter the mode. 

- The flashing arrow indicates the current date: 
Use the [+] and [-] buttons to set the current date. 
- Press the button again to confirm. The display now 
shows the current time to be set. 
“Hours”: use the buttons to set the hour and confirm with the

 [Prog]

 button. 

“Minutes”: repeat the same procedure and confirm with the 

 [Prog] 

button. 

When the procedure is complete, the thermostat returns to “Stand-by” mode. 

 
 
 
 
 
 

 

 

 

CALEIDO srl . via Pablo Neruda, 52/a . 25020 Flero (BS) . Italy 
Tel +39 030 2530054 - Fax +39 030 2530533 
[email protected] 

caleido.it 

Содержание M1/M1CR

Страница 1: ...e screws and plugs supplied or replace them with others which have the same or better mechanical properties CAUTION This appliance is only intended for heating textiles washed in water CAUTION If anti...

Страница 2: ...above warnings into consideration the radiator can be installed in areas 2 and 3 as shown in Figure 1 INSTALLING THE RADIATOR The radiator must not be installed in a niche or under a socket Any eleme...

Страница 3: ...imer 2h and Stand by Comfort mode The thermostat maintains the room temperature at the value set by the user Night mode The thermostat keeps the temperature at a lower value than the Comfort temperatu...

Страница 4: ...I only Room temperature sensor 10KOhm at 25 C Type NTC Power cord H05VVF HAR L 900mm 3x1mmq Class II Fil pilot 2x1mmq Class II 3x1mmq Class I Colours available White RAL9003 White RAL9003 cable Chrome...

Страница 5: ...e premature destruction of the heating element could damage the radiator 7 Ensure that the power of the heating element does not exceed the power of the controller see technical plate 8 When installed...

Страница 6: ...ins the temperature 3 5 C below the Comfort temperature 4 Anti freeze prevents the temperature from falling below 7 C 5 Eco 1 maintains the temperature 1 C below the Comfort temperature 6 Eco 2 mainta...

Страница 7: ...nctions described below 1 Standby switches off the heating element thermostat stays on 2 Comfort maintains the Comfort temperature set by the user 3 Eco maintains the ambient temperature 3 5 C below t...

Страница 8: ...og button to confirm and return to stand by mode When the function is activated the open window symbol remains permanently lit When the device detects the open window the symbol flashes When the funct...

Отзывы: