Caleido M1/M1CR Скачать руководство пользователя страница 6

 

"Fil-

Pilot” 

station 

Comfort Bar/Night 
mode Chrono. 

24h indicator. 

Clock. 

Function: 
"Open window sensor". 

Day of the week. 

"Key lock" icon 

Remote control signal 
reception indicator 

Operating mode icons: 
1) Fil-Pilot 

2) Comfort 

3) Night 

4) Antifreeze 

5) Timer 

6) Chrono 

(in the following order from left to right). 

Set temperature 

Heating element 
active symbol. 

 

 

CONNECTION TO THE FIL-PILOT SYSTEM 

 

(For versions with Fil-Pilot only) Example: 

 

Living room 

 

Bathroom 

 

Room 1 

 

Room 2 

 

 

1. 

M1 / M2 with “Fil-Pilot” function (class II) can be remotely controlled by a control unit that supports the “Fil-Pilot” system. The brown wire is 

live (L), the grey wire is neutral (N), and the black wire is used to receive the Fil-Pilot signal. 

Do not connect the black wire to earth. 

 

2. 

M1 / M2 without “Fil-Pilot” function (class I) cannot be remotely controlled. 

The brown wire is live (L), the blue wire is neutral (N), and the yellow/green wire must be connected to earth. 

 

FIL-PILOT 

 

The "Fil-

Pilot” system manages six different types of signal. 

 

1. 

Standby: 

switches off the heating element, but the thermostat stays on. 

2. 

Comfort

: maintains the "Comfort" temperature set by the user. 

3. 

ECO: 

maintains the temperature 3.5°C below the "Comfort” temperature. 

4. 

Anti-freeze: 

prevents the temperature from falling below 7°C. 

5. 

Eco-1: 

maintains the temperature 1°C below the "Comfort” temperature. 

6. 

Eco-2: 

maintains the temperature 2°C below th

e "Comfort” temperature. 

 

USER MANUAL 

 

 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fil-Pilot 

Comfort 

Night 

Anti-
freeze 

2H timer 

Chrono 

 

"ON / STAND-

BY” BUTTON 

 

Press the [On/Stand-by) button to 

switch on the appliance or activate the “Stand-by” mode. 

When active, the lower area of the display shows the current time, while the mode setting, and temperature are shown at the top. During 
"Stand-by" the display shows "Stb", the current time and the day of the week. 

NOTE: 

When the device enters 'Stand-by' mode, two 0.5 second beeps are emitted. When the device is switched on, one 

1-second beep is emitted. 

 

Example of the display in “Comfort” mode. 

Example of the display in “Stand-by” mode. 

 

Class II 

thermost
at 

Class II 

thermost
at 

Class II 

thermost
at 

Class I 

thermost
at 

"Fil-Pilot" 

Live

 

Neutra
l

 

~230V 

AC/50HZ 

Switch 

Switch 

Switch 

Switch 

Thermostat 

Thermostat 

Thermostat 

Thermostat 

• Always disconnect the electricity supply from the mains during installation. 

• The electronic thermostat may only be connected to the heating element by qualified personnel. 

• Ensure that the power of the resistance does not exceed the maximum power allowed by the electronic control. 

Содержание M1/M1CR

Страница 1: ...e screws and plugs supplied or replace them with others which have the same or better mechanical properties CAUTION This appliance is only intended for heating textiles washed in water CAUTION If anti...

Страница 2: ...above warnings into consideration the radiator can be installed in areas 2 and 3 as shown in Figure 1 INSTALLING THE RADIATOR The radiator must not be installed in a niche or under a socket Any eleme...

Страница 3: ...imer 2h and Stand by Comfort mode The thermostat maintains the room temperature at the value set by the user Night mode The thermostat keeps the temperature at a lower value than the Comfort temperatu...

Страница 4: ...I only Room temperature sensor 10KOhm at 25 C Type NTC Power cord H05VVF HAR L 900mm 3x1mmq Class II Fil pilot 2x1mmq Class II 3x1mmq Class I Colours available White RAL9003 White RAL9003 cable Chrome...

Страница 5: ...e premature destruction of the heating element could damage the radiator 7 Ensure that the power of the heating element does not exceed the power of the controller see technical plate 8 When installed...

Страница 6: ...ins the temperature 3 5 C below the Comfort temperature 4 Anti freeze prevents the temperature from falling below 7 C 5 Eco 1 maintains the temperature 1 C below the Comfort temperature 6 Eco 2 mainta...

Страница 7: ...nctions described below 1 Standby switches off the heating element thermostat stays on 2 Comfort maintains the Comfort temperature set by the user 3 Eco maintains the ambient temperature 3 5 C below t...

Страница 8: ...og button to confirm and return to stand by mode When the function is activated the open window symbol remains permanently lit When the device detects the open window the symbol flashes When the funct...

Отзывы: