![Caleido M1/M1CR Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/caleido/m1-m1cr/m1-m1cr_technical-manual_3389535006.webp)
6
"Fil-
Pilot”
station
Comfort Bar/Night
mode Chrono.
24h indicator.
Clock.
Function:
"Open window sensor".
Day of the week.
"Key lock" icon
Remote control signal
reception indicator
Operating mode icons:
1) Fil-Pilot
2) Comfort
3) Night
4) Antifreeze
5) Timer
6) Chrono
(in the following order from left to right).
Set temperature
Heating element
active symbol.
CONNECTION TO THE FIL-PILOT SYSTEM
(For versions with Fil-Pilot only) Example:
Living room
Bathroom
Room 1
Room 2
1.
M1 / M2 with “Fil-Pilot” function (class II) can be remotely controlled by a control unit that supports the “Fil-Pilot” system. The brown wire is
live (L), the grey wire is neutral (N), and the black wire is used to receive the Fil-Pilot signal.
Do not connect the black wire to earth.
2.
M1 / M2 without “Fil-Pilot” function (class I) cannot be remotely controlled.
The brown wire is live (L), the blue wire is neutral (N), and the yellow/green wire must be connected to earth.
FIL-PILOT
The "Fil-
Pilot” system manages six different types of signal.
1.
Standby:
switches off the heating element, but the thermostat stays on.
2.
Comfort
: maintains the "Comfort" temperature set by the user.
3.
ECO:
maintains the temperature 3.5°C below the "Comfort” temperature.
4.
Anti-freeze:
prevents the temperature from falling below 7°C.
5.
Eco-1:
maintains the temperature 1°C below the "Comfort” temperature.
6.
Eco-2:
maintains the temperature 2°C below th
e "Comfort” temperature.
USER MANUAL
Fil-Pilot
Comfort
Night
Anti-
freeze
2H timer
Chrono
"ON / STAND-
BY” BUTTON
Press the [On/Stand-by) button to
switch on the appliance or activate the “Stand-by” mode.
When active, the lower area of the display shows the current time, while the mode setting, and temperature are shown at the top. During
"Stand-by" the display shows "Stb", the current time and the day of the week.
NOTE:
When the device enters 'Stand-by' mode, two 0.5 second beeps are emitted. When the device is switched on, one
1-second beep is emitted.
Example of the display in “Comfort” mode.
Example of the display in “Stand-by” mode.
Class II
thermost
at
Class II
thermost
at
Class II
thermost
at
Class I
thermost
at
"Fil-Pilot"
Live
Neutra
l
~230V
AC/50HZ
Switch
Switch
Switch
Switch
Thermostat
Thermostat
Thermostat
Thermostat
• Always disconnect the electricity supply from the mains during installation.
• The electronic thermostat may only be connected to the heating element by qualified personnel.
• Ensure that the power of the resistance does not exceed the maximum power allowed by the electronic control.