background image

Troubleshooting

Under normal operating conditions the Caleffi AngleMix 520 series thermostatic mixing valve 
will provide a very high level of performance. However, in some circumstances, where the 
following maintenance schedule is not followed problems may arise.

Recommended maintenance schedule:

Tests should be conducted regularly to monitor the thermostatic mixing valve performance, 
as deterioration of performance could indicate that the valve and/or the system require 
maintenance. If, during these tests, the temperature of the mixed water has changed 
significantly in comparison with the previous test, the details given in the installation and 
commissioning sections should be checked and maintenance conducted.
The following should be checked regularly to ensure that the optimum performance levels of 
the valve are maintained. Check every 12 months at least, or more often if necessary.
1) Check and clean the system filters.
2) Check that any check valves positioned upstream of the Caleffi thermostatic mixing valve are 
operating correctly, without problems caused by impuritites.
3) Limescale can be removed from internal components of the thermostatic mixing valve by 
immersion in a suitable de-scaling fluid.
4) When the components which can be maintained have been checked, commission the valve.

Symptoms

Cause

Corrective action

Hot water at the cold taps

a) Operation of check valve is 

hindered; Check valve is not 

sealing correctly. 

b) Check valves not fitted.

- Replace faulty check valve

Fluctuating mixed water 

temperature

a) Erratic supply temperatures at 

the inlet of the valve. 

b) Starvation of the water 

supplies at the inlets of the valve. 

c) Incorrect commissioning of the 

valve.

- Restore inlet conditions within 

the limits of the valve.

Erratic flow of water from 

the valve

a) Insufficient water supplies 

b) Fluctuations in the supply 

pressures/temperatures. 

c) Adverse effect created by other 

draw off points on the system

- Stabilize inlet supply condi-

tions.

No flow of water from the 

valve

a) In-line filers blocked. 

b) Insufficient supply pressures. 

c) Debris obstructing valve 

operation.

- Clean filters 

- Resore inlet supplies 

- Clean debris or scale from 

the valve.

Valve shut-off function not 

performed when tested

a) Installation not compliant with 

instructions. 

b) Minimum temperature differ-

ence not reached. 

c) Valve mechanism blocked 

by dirt.

- Follow installation instructions. 

- Increase hot water 

temperature. 

- Remove dirt/limescale from 

the valve.

10

Содержание AngleMix 520 Series

Страница 1: ...tlet temperature gauge and angle body connections press and sweat union 5205__AC series Adjustable three way thermostatic mixing valve with mixed outlet temperature gauge anglebodywithinletportcheckva...

Страница 2: ...hen making the water connections make sure that the pipwork connecting the AngleMix thermostatic mixing valve is not mechanically overstressed Over time this could cause breakages with consequent wate...

Страница 3: ...ifi form la bonne application installation et maintenance des syst mes conform ment aux codes et r glements locaux ATTENTION Siler ducteurdepression termostaticoregolabile n estpasinstall mis en servi...

Страница 4: ...inlet If the inlet temperature or pressure changes the internal element automatically reacts to restore the set temperature at the outlet The AngleMix 520 series point of distribution mixing valve is...

Страница 5: ...thus preventing the delivery of mixed temperature water This is only guaranteed when there is a minimum temperature difference between the inlet hot water and the mixed temperature water delivery of...

Страница 6: ...tic mixing valve body Hot water inlet color red and marked HOT Cold water inlet color blue and marked COLD Mixed water outlet marked MIX Locking the setting Position the handle to the number required...

Страница 7: ...90 210 F Code A B C D Wt lb 520516A 3 4 press 4 8 413 16 2 8 520516AC 3 4 press with inlet checks 4 11 63 4 2 8 520519A 3 4 sweat 4 7 47 16 2 8 520519A 3 4 press with inlet checks 4 10 6 2 8 Lay lengt...

Страница 8: ...temperature of the mixed water emerging at the point of use 3 The maximum outlet temperature from the valve must be set accounting for fluctuations due to simultaneous use It is essential for these co...

Страница 9: ...ion vessel Thermostat Temperature pressure safety relief valve Safety relief valve Pressure reducing valve Y strainer T MAIN WATER SUPPLY MAIN WATER SUPPLY MAIN WATER SUPPLY SYSTEM WITHOUT RECIRCULATI...

Страница 10: ...nal components of the thermostatic mixing valve by immersion in a suitable de scaling fluid 4 When the components which can be maintained have been checked commission the valve Symptoms Cause Correcti...

Страница 11: ...NOTES 11...

Страница 12: ...Caleffi North America Inc 3883 West Milwaukee Road Milwaukee WI 53208 T 414 238 2360 F 414 238 2366 11 15 18 12...

Отзывы: