Condominium Data Sheet

CONDOMINIUM DATA SHEET

Fax

Condominium name

* Indicate the grand total of ALL the APARTMENT SURVEY SHEETS of the condominium

Street

Number

Tax code number

Postal code

City

Province

ST

AMP AND SIGNA

TURE

BUILDING 

ADMINISTRATOR/

MANAGER

Denomination

No. of buildings*

No. of dwellings*

No. of radiators

*

No. of towel

 warmers/

radiators

*

No. of conv

ectors*

No. of MONITOR 2.0 

heat c

ost allocators*

No. of MONITOR 2.0 E 

heat c

ost allocators*

Address

Name and s

urname

Phone/mobi

le no.

Fa

x

E-m

a

il

Denomination

Address

Name and s

urname

Phone/mobi

le no.

E-m

a

il

TECHNICIAN 

(who did the survey)

No. domestic

hot water

volume meter

No. of

MONITOR 2.0 PULSE 

pulse acquisition device*

No. domestic

cold water

volume meter

Содержание 7200 Series

Страница 1: ...of heat consumption are performed obtaining improved comfort quantification of the actual heat consumption and a fair allocation of costs The heat consumption data can be collected via radio and proce...

Страница 2: ...tion 35 code 720050 Kit Table 1 on pages 11 12 32 code 720020 MONITOR 2 0 heat cost allocator 32 code 200000 Thermostatic control head for radiator valves Code 720050 comes in a minimum 5 piece pack a...

Страница 3: ...r 75 mm plate 55 mm anchor 20 39 mm anchor 59 mm plate 55 mm anchor 75 mm plate 88 mm anchor 39 mm plate 88 mm anchor 59 mm anchor 75 mm plate 88 mm anchor 75 mm screws M4 x 130 mm plate 39 mm self ta...

Страница 4: ...ed during installation 4 Display selection button 5 Retaining screws tightening torque 0 8 1 N m 6 Aluminium thermal coupling plate 7 Fastening brackets 1 Anti tampering seal 2 Heat cost allocator com...

Страница 5: ...downward STEP 3 Press down on the bottom part of the heat cost allocator until it is securely in place a b a b MONITOR 2 0 MONITOR 2 0 E 2 0 PULSE MONITOR 2 0 2 0 E 2 0 PULSE a b 2 INSTALLATION AND M...

Страница 6: ...st to the valve Cut off the excess part using cutting nippers as it may damage the device YES NO The heat cost allocator positioning indicator must ALWAYS be positioned exactly at 75 1 cm of the heigh...

Страница 7: ...ed exactly at 75 1 cm of the development of the coil or at 50 1 cm of the height in the case of a single block convector 2 INSTALLATION AND MAPPING to be carried out by the installer MONITOR 2 0 E wit...

Страница 8: ...e volume meter to the device inputs with screw terminals Figure A as illustrated in the picture below Positioning the consumption data acquisition device In order to guarantee correct operation of the...

Страница 9: ...s smooth columns Material Type Description UNI 10200 type Small columns Section 30 x 30 mm Large columns Section 30 x 30 mm hub 50 mm hub 55 mm hub 55 mm hub 60 mm A B C D Columns joined by diaphragm...

Страница 10: ...st allocator serial number MONITOR 2 0 2 0 E Radiator cover S shelf distance 15 cm C full cover S C C C C C C KITCHEN LIVING ROOM MASTER BEDROOM BATHROOM HALL H mm W mm D mm 2 0 E 2 0 E 2 0 E 2 0 E 2...

Страница 11: ...etween elements D less than or equal to 35 mm Distance between elements D from 36 to 45 mm 720051 720053 Minimum 5 piece pack 4 4 Distance between elements D less than or equal to 4 mm Distance betwee...

Страница 12: ...tubes 720062 Smooth surface Lamellar radiators Lamellar Lamellar 720063 Towel warmer Horizontal tubes 720050 Distance between elements D from 24 to 28 mm D 24 D 28 Towel radiator MOUNTING KIT MOUNTING...

Страница 13: ...t coil Double or triple element without coil Single double or triple element with coil Coil convector Single fin convector Single block convector mounting kit included in the heat cost allocator pack...

Страница 14: ...columns Highly finned Averagely finned Lightly finned Plate without fins With rear fins With fins between the plates Vertical or horizontal tubes G H I L M N O P Cast iron or steel Bare tube Cast iron...

Страница 15: ...Denomination No of buildings No of dwellings No of radiators No of towel warmers radiators No of conv ectors No of MONITOR 2 0 heat cost allocators No of MONITOR 2 0 E heat cost allocators Address Nam...

Страница 16: ...which condominium dwelling and room they correspond RADIATOR CONVECTOR 1 1 If convectors are present it is necessary to fill the Installed capacity W field 6 T 60 C TOWEL RADIATORS 2 DOMESTIC HOT COLD...

Страница 17: ...ogrammed by means of the USB radio device code 720090 and the software provided Normally parameterisation is done in one go when installation has been completed and the mapping data of the specific bu...

Страница 18: ...RESET Reset date li57 ba FW VERSION INSTALLED Shows the firmware version installed OTHER MESSAGES DIFFERENT FROM THOSE LISTED ABOVE ARE STRICTLY FOR QUALIFIED TECHNICAL PERSONNEL 88 88 88 EXXXXX FXXX...

Страница 19: ...MPTION First 4 digits of the total consumption of the previous year PREVIOUS PERIOD CONSUMPTION Last 4 digits of the total consumption of the previous year PREVIOUS YEAR CONSUMPTION LOGGING DATE Day m...

Страница 20: ...have it fastened The display shows the alert code FL8888 or Fr8888 The internal self test has detected a fault Contact a certified installer and specify the code FL8888 or Fr8888 Null consumption is...