10
2. INSTALLATION AND MAPPING (to be carried out by the installer)
MONITOR 2.0 - 2.0 E (remote probe)
2. INSTALLATION AND MAPPING (to be carried out by the installer)
MONITOR 2.0 PULSE (pulse acquirer)
Dimensions
Specify the dimensions of the heat emitter
expressed in mm
.
Brand, series and model
Specify, if possible, brand, series and model of the
towel warmer.
Installed capacity (W)
Specify, if possible, the installed thermal capacity referring to
D
T 60°C.
MONITOR 2.0 E heat cost allocator with remote probe
Tick ONLY if the heat cost allocator is fitted with a remote probe
(MONITOR 2.0 E).
Stair, floor and room
Specify the stair, floor and room where the
MONITOR 2.0 PULSE is installed.
Serial number of the
acquirer
MONITOR 2.0 PULSE
Enter the serial number
indicated on the label on
the top part of the heat
cost allocator.
DHW or DCW
Specify whether the device
is connected to a hot or
cold water volume meter
Other type of meter
In case the MONITOR 2.0 PULSE is not connected to a volume
meter, specify the type (e.g.: heat meter).
K (litres/pulse or kWh/pulse)
Specify the K value (litres/pulse) that characterize the volume
meter or the K value (kWh/pulse) in case of a heat meter.
Diameter of the volume meter
Specify the diameter of the volume meter or the diameter of
heat meter
Initial value to be set
Specify the initial value to be set into the pulse acquirer,
expressed in m
3
for a volume meter (in kWh for a heat meter)
displayed on the meter at the moment of the installation of the
MONITOR 2.0 PULSE acquirer.
ATTENTION : the initial value is MANDATORY for the
parameterization!
Serial number of the volume meter
Specify the serial number of the volume meter or the one of the
heat meter connected to the pulse acquirer.
854
BRAND 1
SERIES 1 MODEL 1
1800
600
30
1
Room
Heat cost allocator serial number
MONITOR 2.0 - 2.0 E
Radiator cover
S = shelf
(distance < 15 cm)
C = full cover
S
C
C
C
C
C
C
KITCHEN
LIVING ROOM
MASTER BEDROOM
BATHROOM
HALL
(*) H (mm)
W (mm)
D (mm)
2.0 E
2.0 E
2.0 E
2.0 E
2.0 E
2.0 E
CHILDREN’S BEDROOM
Type
UNI 10200
See TAB. 2
Example: A
Installed
capacity (W)
Δ
T
60°C
Brand
Series
Model
Type
EN 442
S
S
S
S
S
2
1
3 4 5 6 7 8
C
2.0 E
S
(2)
If you do not have the brand-name, series and model of the towel warmer or radiator, you need to send an e-mail to the address
attaching a
photo
and indicating the
tube and manifolds diameters
and to which condominium, dwelling and
room they correspond.
RADIATOR / CONVECTOR /
(1)
(1) If convectors are present it is necessary to fill the “Installed capacity (W) field.
Δ
T 60°C”
TOWEL RADIATORS
(2)
Dimensions
(*) H means the height of the radiator and
NOT
the distance between hub centres
No. of
elements
Tick if the heat
cost allocator
is with remote
probe
(
MONITOR 2.0 E)
TIMBRO E FIRMA
A
1
KITCHEN
1 2 3 4 5 6 7 8
X
10
3/4”
15,203
0123456789
DOMESTIC HOT / COLD WATER VOLUME METER
Stair
Floor
Room
Serial number of the acquirer
MONITOR 2.0 PULSE
Domestic hot or
cold water
DHW DCW
Other type of meter
K
(litres/pulse or
kWh/pulse)
Initial value to be set
(m
3
or kWh)
Serial number of the
volume meter
DHW DCW
DHW DCW
DHW DCW
Diameter of the
volume meter
Example of data entry for a volume meter :
Example of data entry for a radiator using EN442:
3
6
5
1
2
3
6
4
1
2
3
6
7
8
9
4
5
10
1
2
3
6
8
9
4
5
10
5
7
Room
Enter the room where the heat emitter is installed.
Heat cost allocator serial
number
Enter the serial number
indicated on the label on
the top part of the heat
cost allocator.
No. of elements
Enter the number of elements the radiator is made of. In
case of towel warmers specify “1”.
8
1
2
Radiator cover
Indicate whether the radiator has a shelf cover S
only if its distance from the radiator is less than 15 cm
or a full cover
C
(tick ONLY if the radiator has a shelf or a full cover).
4
8
7
7