background image

A

Sweat version

E

D

A

30

50

70

90

110 130

150

170
190

210

F

A

F

E

D

B

B

C

A

A

H

C

Code

A

B

C

D

E

F

Wt 

(lb)

NA10366

1" NPT

5 1/2"

10 7/8"

7 5/8"

4 3/16"

3 3/8"

9.0

1" SWT

4 3/4"

9 1/2"

7"

3 1/2"

3 3/8"

9.0

1 1/4" NPT

5 5/8"

11 1/8"

7 3/4"

4 5/16"

3 3/8"

9.0

1 1/4" SWT

4 3/4"

9 5/8"

7 5/8"

4 1/8"

3 3/8"

11.0

1 1/4" SWT

4 3/4"

9 5/8"

7"

3 1/2"

3 3/8"

9.0

NA10367

1 1/2" NPT

7 3/8"

14 3/4"

9 3/16"

5 7/16"

3 3/4"

19

1 1/2" SWT

6 1/4"

12 5/8"

8 1/8"

4 3/8"

3 3/4"

19

2" NPT

7 3/8"

14 3/4"

9 1/2"

5 3/4"

3 3/4"

20

2" SWT

6 1/2"

13 1/8"

8 5/8"

4 7/8"

3 3/4"

20

Dimensions for 5231 models with field installed inlet check valve assembles, code 
numbers listed in first column.

Dimensions with check valves

8

Содержание 5231 Series

Страница 1: ...cal characteristics Materials body DZR low lead brass 0 25 lead content shutter PPSG40 springs stainless steel seals peroxide cured EPDM check valve extension field installed stainless steel www calef...

Страница 2: ...operate correctly and may endanger the user CAUTION Make sure that all the connecting pipework is water tight CAUTION When making the water connections make sure that the pipework connecting the therm...

Страница 3: ...des syst mes conform ment aux codes et r glements locaux ATTENTION Siler ducteurdepression termostaticoregolabile n estpasinstall mis en service et entretenu correctement selon les instructions conten...

Страница 4: ...20 F 11 C to ensure the correct operation and maximum pressure difference between the hot and cold inlet parts no greater than 2 1 ratio Softened water use is highly recommended as the warranty is vo...

Страница 5: ...10 2 0 5 0 115 172 75 Flow should never exceed standards for pipe size and material Size Connection Model Min Flow GPM Max Flow GPM CV 1 NPT 523160A 4 4 40 7 1 Sweat 523168A 4 4 40 7 1 NPT 523170A 4...

Страница 6: ...s may affect performance and the manufacturer s product guarantee Softened water use is highly recommended as the warranty is voided if used on water with hardness greater than 10 grains The installat...

Страница 7: ...1 1 4 NPT 4 1 8 8 1 4 7 3 4 4 5 16 3 3 8 7 0 523177A 1 1 4 SWT 3 3 8 6 3 4 7 5 8 4 1 8 3 3 8 9 0 523178A 1 1 4 SWT 3 3 8 6 3 4 7 3 1 2 3 3 8 7 0 523180A 1 1 2 NPT 5 1 8 10 1 4 9 3 16 5 7 16 3 3 4 17 5...

Страница 8: ...5 16 3 3 8 9 0 1 1 4 SWT 4 3 4 9 5 8 7 5 8 4 1 8 3 3 8 11 0 1 1 4 SWT 4 3 4 9 5 8 7 3 1 2 3 3 8 9 0 NA10367 1 1 2 NPT 7 3 8 14 3 4 9 3 16 5 7 16 3 3 4 19 1 1 2 SWT 6 1 4 12 5 8 8 1 8 4 3 8 3 3 4 19 2...

Страница 9: ...ptor fits high flow 5231 series mixing valves Removable gauge fits into temperature well Gauge dial is 2 diameter and scale from 30 210 F Low lead brass body Code Description Lbs NA10315 1 sweat with...

Страница 10: ...xed water temperature to 120 F in domestic hot water systems Maintenance Service tests should be carried out regularly to monitor the mixing valve performance as deterioration of performance could ind...

Страница 11: ...LEFFI CALEFFI 10 0 8 6 4 2 10 0 8 6 4 2 CALEFFI CALEFFI 10 0 8 6 4 2 10 0 8 6 4 2 10 0 8 6 4 2 10 0 8 6 4 2 T Key to symbols Safetyrelief valve Check valve Isolation valve Expansion vessel Filter Pump...

Страница 12: ...fitted Replace faulty check valves Fluctuating mixer water temperature a Erratic supply temperatures at the inlets of the valve b Starvation of the water supplies at the inlets of the valve c Incorrec...