Function

The thermostatic mixer is used in solar thermal systems

producing domestic hot water. Its function is to maintain the

temperature of the mixed water supplied to the user constant at

the set value when there are variations in the supply conditions

of the incoming hot and cold water. This particular series of

mixing valves can function continuously at the high

temperatures of   incoming hot water from the solar storage tank.

The valve has been specifically certified to ASSE 1017.

Product range

Series 2521 thermostatic mixing valve. Union thread NPT male

connections, sizes 1/2”, 3/4”,1”; union solder connection, size

1/2”, 3/4”, 1”.

Technical Characteristics

· Materials: - Body:

Low

-

lead brass

(<0.25% Lead content), chrome plated

- Shutter:

PSU

- Springs:

Stainless steel

- Seals:

EPDM

· Setting range:

85–150°F (30–65°C)

· Accuracy:

±3°F (±2°C)

· Max working pressure (static):

200 psi (14 Bar)

· Max working pressure (dynamic):

75 psi (5 bar)

· Min working pressure (dynamic):

3 psi (0.2 bar)

· Max hot water inlet temperature:

212°F (100°C)

· Maximum inlet pressure ratio (H/C or C/H):

2:1

· Minimum temperature difference between hot water inlet and

mixed water outlet for optimum performance:

30°F (15°C)

· Min. flow rate to ensure stable temperature: 1.3 gpm (5 lpm)

· Certified to:

ASSE 1017

· Lead Plumbing Law Compliance:

(0.25% Max. weighted

average lead content)

· Lead Plumbing Law Certified by ICC-ES, file MPG-1360.

Adjustable Thermostatic Mixing Valve for Solar Systems

2521 Series

28114.02

INSTALLATION AND COMMISSIONING MANUAL

ASSE 1017

© Copyright 2018 Caleffi

www.caleffi.com

CALEFFI

·

Installation Tip

Scan to view

2521 Solar Mixing V

alve

Содержание 252169A

Страница 1: ...s 0 25 Lead content chrome plated Shutter PSU Springs Stainless steel Seals EPDM Setting range 85 150 F 30 65 C Accuracy 3 F 2 C Max working pressure static 200 psi 14 Bar Max working pressure dynamic...

Страница 2: ...peratures do not endanger people CAUTION In the case of highly aggressive water arrangements must be made to treat the water before it enters the thermostatic mixer in accordance with current legislat...

Страница 3: ...een the hot and cold water passages Even when there are pressure drops due to the drawing off of hot or cold water for other uses or variations in the incoming temperature the mixer automatically regu...

Страница 4: ...diagram 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Regulating knob Head fixing screw Regulating spindle O Ring seal Upper shutter seat Thermostatic element Inner shutter O Ring Outer shutter O Ring O...

Страница 5: ...manual taking into account all current applicable standards Caleffi 2521 series mixing valve can be installed in any position either vertical or horizontal The following are shown on the valve body H...

Страница 6: ...agrams COLD BLUE HOT RED MIX Key to symbols Safety relief valve Isolation and check valve Isolation valve Expansion vessel Filter HOT COLD MIX MIN MAX 7 1 2 HOT COLD CALEFFI MIN MAX 7 1 2 T Normally c...

Страница 7: ...red Unscrew the head screw pull off the handle and reposition it so that the handle fits into the internal slot of the knob Tighten the head screw Maintenance In service tests should be carried out re...

Страница 8: ...water supplies at the inlets of the valve c Incorrect commissioning of the valve a Insufficient water supplies b Fluctuations in supply pressures temperatures c Adverse effect created by other draw o...