Standard system with 1 tank, 1 pump and 3 
sensors. S4 / TRF can be used as BTU meter

System and heat exchange with an existing
tank with 1 tank, 4 sensors and 2 pumps

Solar system and backup heating with 1 tank, 3 
sensors. S4 / TRF can be used as BTU meter

2-tank-solar system with valve logic, 3 
sensors, 1 solar pump and 3-way valve. 
Sensor S4 / TRF can used as BTU meter

2-tank solar system with pump logic, 3
sensors and 2 solar pumps

Solar system with east-west collectors, 
1 tank, 3 sensors and 2 solar pumps.

System with backup heating by wood boiler
with 1 tank, 4 sensors, 1 solar pump and 
1 pump for backup heating.

System and heating circuit pre-heat with
1 tank, 4 sensors, 1 solar pump and 3-way
valve for heating circuit.

S2

R1

S3

R2

S1

S4 / TRL

System and tank charge in layers with 1 tank,
3 sensors, 1 solar pump and 3-way valve.
Sensor S4 / TRF can be used as BTU meter 

R2

S1

S2

R1

S3

S4 / TRL

Solar system and heat dumping with 1 tank, 3 
sensors. S4 / TRF can be used as BTU meter

iSolar 1

iSolar 2

iSolar 3

iSolar Plus

Electronic relayy

0

1

0

2

Standard relay

1

0

2

0

Pump speed control

no

yes

no

yes

Operating hours counter

yes

yes

yes

yes

kWh (BTU) measurement

yes

yes

yes

yes

V-bus for data recorder

yes

yes

yes

yes

PC-interface RS232

yes

yes

yes

yes

Heat dumping function

no

no

yes

yes

Backup heat function

no

no

yes

yes

Additional

Δ

T control

no

no

no

yes

Two-tank priority

no

no

no

yes

Clock with scheduling

no

no

no

yes

A

0

6

2

7

5

2

A

0

1

3

7

5

2

A

0

2

2

7

5

2

A

0

1

2

7

5

2

e

d

o

C

Selectable programs                    1

1                2

  9

Standard operation functions  

T control 

- When the switch-on difference is reached, the pump is activated until 

     the differential temperature drops below.

Maximum tank temperature 

- When the adjusted maximum tank temperature is 

     exceeded, the pump switches off.

Collector emergency shutdown 

- If adjusted collector temperature is exceeded, 

     the solar pump is switched off.

System cooling 

- If the temperature rises to the maximum collector temperature 

     the solar pump remains on until this temperature drops.

Minimum collector temperature 

- a minimum set temperature which must be 

     exceeded before the solar pump is switched-on.

Antifreeze function 

- If the adjusted temperature drops, the solar pump is switched

     on to protect the fluid from freezing.

Tank cooling function 

- In the evening, the solar pump continues running until 

     the storage tank is cooled down.

Tube collector function 

- The controller measures an increase of heat rise in the 

     collector and adjusts operating time for maximum efficiency.

Heat generation measurement kWh (BTU) 

- The heat generated is measured by 

     the volume flow and the temperature of feed and return sensors.

Operating hours counter - 

Operating hours counter stores the solar operating

     hours of the respective relay.

Manual operating mode 

- For control and servicing, the operating mode of the 

     controller can be switched manually.

Heat dumping function 

- Heat dumping function works independently from the 

     solar operation and activates the second relay.

Backup heating function 

- Backup heating function works independently from 

     the solar operation and activates the second relay.

Second independent 

T control 

- The switch on and off temperatures can be 

     adjusted separately.

Priority tank / tank rotation 

- The controller checks the tank temperatures and 

     rotates or gives priority to charging tanks.

East / West collectors

 - Two separate

 

T controls activate each solar pump 

     based on collectors and the one-tank differential temperature.

Advanced operation functions 

(some two-relay models)

Pump speed control functions

Pump speed control can improve system efficiency by reducing the flow to
the collectors on cloudy days to improve solar thermal transfer and reduce 
electrical consumption. This is achieved by the differential temperature 
value between the collectors and storage tank.
If the value for the 

Δ

T switch-on is reached (e.g. 

Δ

T on = 9º ), the pump 

will start with 100% pump speed for 10 seconds, then reduce the speed to 
the adjusted minimum pump speed (min. pump speed = 30 %, adjustable). 
If the temperature difference reaches the set value (e.g. 

Δ

T Set = 18º ), 

pump speed will increase by 10 %. At any further rise of 3º  

Δ

T the pump 

speed will increase by 10% until the maximum of 100% is reached.