manualshive.com logo in svg
background image

29

S

pa

 c

are

 

and

 m

aIntenance

 

Your 

CALDERA

 spa is manufactured from the highest quality, most 

durable materials available. Even so, the spa care and maintenance 

program you develop will ultimately determine how long your spa, and its 

individual components, will last. Regular maintenance and following the 

advice in this section will help you to protect your investment.

DRAIN & REFILL INSTRUCTIONS

IMPORTANT: 

It is NOT recommended to refill your spa when the ambient 

temperature goes below 10° C (50° F).

1.  Disconnect the spa from the power supply by tripping both of the GFCI breakers 

located in the subpanel. Unplug power cord for 115V models.

2.  Locate the drain valve for the spa (lower front of the spa) and 

remove the drain cap. Attach the inlet of a garden hose to the drain 

valve (to avoid flooding of the foundation surrounding the spa) and 

route the outlet of the hose to an appropriate draining area. Spa 

water with a high sanitizer level may harm plants and grass.

3.  Open the drain valve by turning the knob. The spa will drain by 

gravitational flow.

IMPORTANT: 

All 

Caldera

 spa models will drain almost completely 

through the drain valve. Equipment such as the jet pump and 

heating system will drain. Any water remaining within the plumbing 

or equipment after draining will only need to be removed if the spa is 

being winterized.

4.  When empty, inspect the spa shell and clean as required. (Follow the 

Care of the Exterior instructions.)

5.  Close the drain valve by reinstall the drain cap.
6.  Install new filter or clean existing with 

MONARCH

 filter cleaner.

7.  Refill the spa through the filter compartment using the 

CLEAN 

SCREEN

 pre-filter. 

IMPORTANT:

 Refill water temperature must be between 10º -21º C 

(50° - 70° F) to avoid high-limit tripping.

8.  Follow the Quick Start-Up instructions on page 14.

COLD WATER REFILL

Should it be necessary to drain and refill your spa in temperatures 

below 10° C (50° F), the spa may go into a High Limit Protection mode 

(causing your spa to stop functioning) if the tap water is below 10° C 

(50° F). Blending warm water with the cold tap water so it exceeds 10° 

C (50° F) during the refilling process will prevent the spa from going into 

the High Limit Protection mode if that is an option for you.

PREVENTION OF FREEZING

Your spa has been designed and engineered for year-round use in any 

climate. In some areas, extremely cold temperatures (below -12° C or 10° 

F) combined with strong wind, may cause partial freezing of the jet pump, 

even though the water inside the spa remains at the selected temperature. 

The energy efficiency of the spa may also decrease during these 

cold periods, as the heater will cycle more frequently. As an additional 

precaution against partial freezing of some of the components, the 

equipment compartment can be insulated with an insulating kit (available 

from your local dealer). This insulating kit will also help to maximize the 

spa’s energy efficiency.

NOTE:

 When warmer weather returns (approx. 16°-21°C or 60-70°F), the 

insulating kit must be removed to prevent overheating of the jet pump.

WINTERIZING YOUR SPA

If you leave the spa unused for a long period of time in severely cold 

weather, you should drain the spa and winterize it to avoid accidental 

freezing due to a power or equipment failure.

 DANGER:

 Use only Propylene Glycol as your anti-freeze (available 

at most RV or marine supply stores). This is non-toxic. Never use an 

automobile anti-freeze (Ethylene Glycol) since it is toxic!

 WARNING

: Failure to follow these instructions correctly can lead to 

freeze damage not covered by warranty.  It is strongly recommended that 

you contact your local 

CALDERA

 dealer to perform this service

1.  Drain your spa following the Drain & Refill Instructions. Open 

waterfall valve. 

2.  Remove the filter cartridge, clean and store in a dry place. 

IMPORTANT:

 These additional instructions must be utilized when 

draining and winterizing your spa in climates where the temperature 

falls below 0°C (32°F). A 20 liters combination (vacuum/blower) 

wet/dry shop vac must be used to effectively remove water that is 

trapped inside the plumbing lines.

3.  Attach the vacuum hose to the vacuum side of the shop vac.  

Vacuum all openings and orifices as follows:
a.  Jet openings: start with the jets at the top and move downward 

(if suction is coming from another jet, block off the other jet 

using a large rag this will help pull out the water that is trapped 

deeper inside the main line).

b.  Filter suction fittings and filter compartment.
c.  Main drain outlet (it may be necessary to cover the drain grate 

tightly with a rag when vacuuming the main drain to ensure 

water is drawn completely from the internal plumbing system).

4.  Thoroughly dry the spa shell with a clean towel.
5.  Replace the main drain cap.  

CAUTION:

 Use only Propylene Glycol as your anti-freeze. This is 

non-toxic. Never use an automobile anti-freeze (Ethylene Glycol) 

since it is toxic!

6.  Using a long-extension funnel, pour anti-freeze into all standpipes, 

filter suction fittings, jet orifices and water feature orifices. Add 

enough anti-freeze to ensure adequate protection – in many cases, 

you will see the liquid in the orifice, or coming out of another 

location.

Front view of pump

DRAIN

PLUG

PUMP DRAIN PLUG LOCATION

Spa Care and Maintenance

Содержание PALATINO

Страница 1: ...VACANZA SERIES 2 0 1 7 O W N E R S M A N U A L 5 0 H z...

Страница 2: ...PA MODEL SERIAL NUMBER ____________________________ COVER SERIAL NUMBER ________________________________ In most cities and counties permits will be required for the installation of electrical circuit...

Страница 3: ...21 MARINO 21 CAPITOLO 22 CELIO 22 AVENTINE 23 WATER QUALITYAND MAINTENANCE BASIC INFORMATION 24 CHEMICAL SAFETY 24 HOW TOADD CHEMICALS TO THE WATER 24 FUNDAMENTALS OF WATER MAINTENANCE 25 FROG CARTRI...

Страница 4: ...due to electrocution if direct burial type cable is not used or if improper digging occurs WARNING To reduce the risk of electrical shock replace a damaged cord immediately Failure to do so may resul...

Страница 5: ...he jet pump for a least ten minutes after adding ANY spa water chemicals into the filter compartment Clean the filter cartridges monthly to remove debris and mineral buildup which may affect the perfo...

Страница 6: ...echnician SPA SHELL Your CALDERA spa has an acrylic shell Stains and dirt generally will not adhere to your spa s surface A soft rag should easily remove most dirt Most household chemicals are harmful...

Страница 7: ...oors Water may get into woodwork and produce dry rot mildew or other problems Check for airborne moisture s effects on exposed wood paper etc in the room To minimize these effects it is best to provid...

Страница 8: ...he eaves are too low the corner is too tight or the stairway is too steep a crane will be required Don t be alarmed The crane has a truck mounted boom which can fit right in your driveway It is run by...

Страница 9: ...uring Corporation recommends that the PALATINO be installed on a minimum 10 cm thick reinforced concrete pad or structurally sound deck able to support the dead weight found in the spa specification c...

Страница 10: ...deck able to support the dead weight found in the spa specification chart IMPORTANT The MARINO must not be shimmed in any manner 6 5 16 5cm 2 5 6 5cm 32 5 82 5cm 36 0 91 0cm 4 0 10 0cm 76 5 194 0cm 8...

Страница 11: ...deck able to support the dead weight found in the spa specification chart IMPORTANT The CAPITOLO must not be shimmed in any manner 6 5 16 5cm 5 0 12 5cm 2 5 6 5cm 29 5 75 0cm 33 0 84 0cm 4 0 10 0cm 74...

Страница 12: ...und deck able to support the dead weight found in the spa specification chart IMPORTANT The CELIO must not be shimmed in any manner 81 5 207 cm 84 0 213 5 cm 65 0 165 cm 62 25 158 cm 4 0 10 cm 30 0 76...

Страница 13: ...minimum 10 cm thick reinforced concrete pad or structurally sound deck able to support the dead weight found in the spa specification chart IMPORTANT The AVENTINE must not be shimmed in any manner 29...

Страница 14: ...d for all electrical circuits to the spa Mount the subpanel according to local codes but not closer than 1 5 meters 5 feet away CONDUIT INSTALLATION INSTRUCTIONS 1 To connect the electrical service fi...

Страница 15: ...ti color LED light system you see multiple points of multi color lighting 8 The water feature adds beauty to your spa experience 9 Pillow All spas come with one or more pillows 10 FROG housing cap 11...

Страница 16: ...ting rotary massage 6 LED dimmable light 7 Pillow Spa comes with one pillow 8 Pillow Spa comes with one pillow 9 Spa Filter provides the water filtration of the spa not shown in overhead picture above...

Страница 17: ...online DO Know which water treatment system you will be using and make sure you have necessary chemicals available Read all of the instructions that come with the system Have MONARCH 5 way Test Strip...

Страница 18: ...hen the water temperature climbs above 32 C 90 F proceed to the next step The spa temperature is pre programmed to reach 38 C 100 F and will normally do so within 18 to 24 hours 5 USING A TEST STRIP A...

Страница 19: ...er is not flowing from any of its jets the pump may not be properly primed To correct refer to the illustration below and perform the following procedures Turn off power to the spa at the breaker and...

Страница 20: ...h Systems jet pumps are off CAPITOLO CELIO AVENTINESPA MODELS ONLY 1st press System 1 jet pump runs on low speed 2nd press System 1 jet pump runs on high speed 3rd press Jet pump off The pump on high...

Страница 21: ...il the TLOK symbol is displayed on the screen Press the button to activate the TEMPERATURE LOCK feature TLOK When the TEMPERATURE LOCK is activated the JETS LIGHTS and any other features your spa may...

Страница 22: ...F for more than three hours the system will cancel the filter cycle for the remaining filter cycle time Should the temperature cool down to 1 5 degrees F 1 degree C below the set point before the end...

Страница 23: ...ss or press button to lower the Bass TO ADJUST BALANCE From the SETUP screen 1 Press the button to display one of three audio sources BLUE TV AUX 2 Press the MODE or button until BAL 5 to 5 is display...

Страница 24: ...ts c 2 ADAPTAFLO Jets and 1 Euro Jet d 4 Euro Jets in footwell System 1 a 8 Euro Jets b 2 ADAPTAFLO Jets c ACQUARELLA Waterfall d 3 Euro Jets e 2 Euro Jets in footwell f 2 Euro Jets and 1 ADAPTAFLO Je...

Страница 25: ...ets f 2 ADAPTASSAGE Jets and 3 Euro Directional Jets in lounge g 1 ADAPTAFLO Jet h 2 Euro Directional Jets in footwell System 1 a 8 Euro Directional Jets b 1 ADAPTAFLO Jet c 2 Euro Directional Jets d...

Страница 26: ...23 System 1 a 2 Euro Jets b 3 ADAPTAFLO Jets c 2 EURO PULSE Jets in arm rests d 4 Euro Jets e 2 ADAPTAFLO Jets f 1 ADAPTAFLO Jet a c d b e f c Jet Menus AVENTINE JET MENU...

Страница 27: ...only a responsible person to handle spa chemicals Keep them out of the reach of children Accurately measure the exact quantities specified never more Do not overdose your spa Handle all containers wit...

Страница 28: ...own sodium bisulfate To raise the pH level use FRESHWATER pH Alkalinity Up sodium carbonate Water Conditioners Spa fill water varies from location to location and user to user therefore it is importan...

Страница 29: ...e spa by adding MONARCH MPS Plus non chlorine shock or sodium dichlor chlorine To replace FROG cartridges follow these steps 1 Turn off power to the spa 2 Unscrew FROG cap on top edge of spa 3 Turn ha...

Страница 30: ...container 3 Run the spa until all of the 0 5 liter of vinegar is gone This should allow an ample flow of vinegar to be run through the injector and clear the blockage 4 Reinstall the tubing to the bo...

Страница 31: ...bines with nitrogen from body oils urine perspiration etc Chloramines can cause eye irritation as well as having a strong odor Unlike bromamines chloramines are weaker slower sanitizers Chlorine An ef...

Страница 32: ...temperature The energy efficiency of the spa may also decrease during these cold periods as the heater will cycle more frequently As an additional precaution against partial freezing of some of the co...

Страница 33: ...fficient filter cycles Depending on how frequently your spa is used we recommend cleaning the spa filter cartridge every four weeks If this is not done the filter may clog and restrict water flow whic...

Страница 34: ...e back of the pillow 4 Keeping the pillow slightly bent slide the other pillow retainer into the recess in the back of the pillow 5 After all the pillow retainers are in place press the pillow down in...

Страница 35: ...se no soap and wipe it clean with a dry rag 6 To condition the cover after cleaning apply MONARCH Cover Shield to protect the cover IMPORTANT To remove tree sap use cigarette lighter fluid not charcoa...

Страница 36: ...tage and therefore may draw more amperage and generate excessive heat This will often cause the circuit breaker to trip repeatedly IMPORTANT 1 If the pump is shutting down due to excessive heat make s...

Страница 37: ...shows POWER READY icon flashes Pressure switch is closed and should be open Contact an Authorized Service Technician Jets weak or surging Spa water level too low Filters clogged suction screens clogg...

Страница 38: ......

Страница 39: ......

Страница 40: ...CATIONS 303766 17 A 9 16 PALATINO Model PLTE 226 cm x 226 cm 98 cm 6 0 m 2 000 1525 L 415 kg 2 420 kg 575 kg m 230 volt 20 amp single phase G F C I circuit MARINO Model MRNE 213 cm x 213 cm 91 cm 6 0...

Отзывы: