background image

4 — 

P

REXISO

 X2 Q

UICK

 S

TART

 G

UIDE

 HOW TO USE

Measuring conditions

The quality of the measurement depends on the surfaces to which you are 
measuring. Strongly reflecting targets deflect the laser beam and cause mea

-

suring errors. Non-reflecting, dark surfaces increase the measuring time.

Always begin by making a control measurement.

Measurement errors

Measuring errors are possible in case of:

  • Colorless fluids (e.g., water)
  • Clean, translucent glass
  • Styrofoam or similar semi-translucent surfaces
  • Strongly reflecting targets that deflect the laser beam
  • Measurements aimed at moving objects

For consistently accurate measurements

• Perform control measurements periodically.
• Perform control measurements before and after important measurements.

Switching on/off 

 

 

(Key 1) 

 

(Key 3)

• Switch on the device by pressing 

Clear/Off

 

 

(Key 1). The device shows the 

Battery

 and 

Measuring Plane 

symbols until another key is pressed.

• Switch off the device by pressing 

Clear/Off

 

 

(Key 3) for 2 seconds. If no 

key is pressed for 3 minutes, the device switches off automatically.

Clear key 

 

(Key 3)

• Undo the most recent action by pressing 

Clear/Off

 

(key 3)  

  briefly.

Adjusting the measuring plane

Rear measuring plane is the 
standard setting.

  • For measurement from front edge,   

      press 

Measuring Plane/Units   

  

    

 

 (key 4) briefly.

  • For measurement from rear edge, 

      press 

Measuring Plane/Units 

    

 

 (key 4) briefly again.

The Front Edge

The Rear Edge

or

MEASURES FROM:

Содержание PREXISO X2

Страница 1: ...Quick Start Guide Model 3350...

Страница 2: ...ractions Exponents Fractions Exponents Units Units Key 1 On Measure distance Key 2 Area Volume Pythagoras Area Volume Pythagoras display Measuring plane display Addition Subtraction display Key 5 Add...

Страница 3: ...ls screwdriver etc Make sure that the device is not modi ed Avoid using accessories that are not recommended by the manufacturer Do not aim the laser beam at shiny re ective surfaces Avoid aiming dire...

Страница 4: ...accurate measurements Perform control measurements periodically Perform control measurements before and after important measurements Switching on off Key 1 Key 3 Switch on the device by pressing Clea...

Страница 5: ...ci c desired distances to be determined Hold On Measure Key 1 for several seconds Continuous measuring starts and display shows trc Press On Measure Key 1 brie y Continuous measuring stops The value l...

Страница 6: ...distance e g height The result is shown in the Main Display and the last distance measured is shown in the Secondary Display Pythagoras Indirect Press Area Volume Pythagoras key 2 three times The Pyt...

Страница 7: ...white paper measuring time too long 256 Input signal too high Change target surface e g white paper 257 Measuring error Shadow the target area too much background light 258 Measurement outside Target...

Страница 8: ...operating ELECTROMAGNETIC COMPATIBILITY EMC Warning Possible disturbance of other devices e g safety equipment medical equipment due to electromagnetic radiation Observe the safety instructions of the...

Страница 9: ...to the website listed below 4 If you believe you need to return your product please call a Calculated Industries representative between the hours of 8 00am and 4 00pm Pacific Time for additional info...

Страница 10: ...s Disclaimer CI MAKES NO WARRANTY OR REPRESENTATION EITHER EXPRESS OR IMPLIED WITH RESPECT TO THE PRODUCT S QUALITY PERFORMANCE MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AS A RESULT THIS PRO...

Страница 11: ...ractions Exponents Fractions Exponents Units Units Key 1 On Measure distance Key 2 Area Volume Pythagoras Area Volume Pythagoras display Measuring plane display Addition Subtraction display Key 5 Add...

Страница 12: ...12 PREXISO X2 QUICK START GUIDE Printed in U S A 1 12 QSG3350E C...

Отзывы: