background image

 

 

COMPANY CONFIDENTIAL: CalAmp reserves all rights to these documents and any information contained therein.

  

Page 

 

Reproduction use or disclosure to third parties without express permission is strictly prohibited. ©2020 CalAmp  

22

 of 

35

 

 

 

 

 

  

 

 

LMU-1300 Training Guide

 

Revision & Date 

0.8–09/22/2020 

o

 

Individual PEG “lines” cannot be updated via Param Write or SMS.  

o

 

When updating a PEG2 script section, you must provide the complete script.   

Note: Configuration Parameters (!CP section) can still be updated as individual parameters via 
Param Write or SMS.  

6.5

 

Event Index Field  

The LMDirect protocol defines the Event Index field as the PEG1 Config Parameter index number 
of the event that generated the report.  

Since this field is limited to 1-byte in the LMDirect protocol and the LMU-1300 uses PEG2 which 
can have an indefinite amount of PEG “Lines”, this field has a slightly new definition. The table 
below indicates the differences: 

PEG1 Event Index 

PEG2 Event Index 

 

Values should range from 0-249.  

 

255 representing a Real Time PEG Action 

request. 

 

Values should range from 0-253.  

 

254 representing any PEG line number 

exceeding 253

 

255 still representing a Real Time PEG Action 

request 

 

6.6

 

Remote Debug PEG Action 

Unlike the LMU32 platforms, EdgeCore (LMU-1300) is always logging at a default level. There is 
no need to “start capturing” data using Peg Action 144, Modifier 1.  To use this PEG Action on the 
EdgeCore there is a different definition of the modifiers as shown in the following table. 

LMU 8 Bit: PEG Action 144 Definition 

LMU-1300: PEG Action 144 Definition 

Peg Action 144 0 - Stop capturing the LMU 
debug in SPI Flash 
Peg Action 144 1 - Start capturing the LMU 
debug into SPI Flash.  
Peg Action 144 2 - Stop capturing and send 
the debug captured so far as a file to the 
server 

 

Peg Action 144 0 - Save log files in a tar ball in 
/data/backup/.  This is useful for someone at 
the AT Console to save logs when desired. 
Peg Action 144 1 - Upload the existing saved 
log if the URL specified by Param 2328 is 
present.   
Peg Action 144 2 - Save log files in a tar ball in 
/data/backup/ and upload the file.  This is good 
for timer or event based log saving. 

 

 

6.7

 

Modem/GPS Reset 

The LMU-1300 hardware architecture does not support rebooting the modem and/or GPS, since 
both are on the same chip, they both use the same power rail. A complete system reboot is 
required to reboot either function.   

Содержание LMU-1300

Страница 1: ...MU 1300 Training Guide CalAmp reserves the rights to these documents and any information contained therein Reproduction use or disclosure to third parties without express permission is strictly prohib...

Страница 2: ...are Specifications 6 3 LMU 1300 Connectors 8 3 1 Primary Connector 8 4 Getting Started 9 4 1 The Basics 9 SIM Card 9 USB Cable 9 Accessing Serial Port 10 4 5 Log File 11 4 6 Backup Logs 11 4 7 File Co...

Страница 3: ...hz vs 5hz GPS Sample Rate 24 6 13 Time Sync Precedence 24 6 14 Version String in ID Reports 24 ID Reports 24 6 15 Firmware Revision Convention 25 6 16 Status LEDs 25 Status LED Behavior 25 6 17 Versio...

Страница 4: ...ntained therein Page Reproduction use or disclosure to third parties without express permission is strictly prohibited 2020 CalAmp 4 of 35 LMU 1300 Training Guide Revision Date 0 8 09 22 2020 7 3 Inbo...

Страница 5: ...during sleep BLE Asset Tag scanner and aggregator 3 axis Accelerometer MEMS and 3 axis Gyroscope Extensive RAM Flash memory space to avoid code space constraints Delta file upgrade capability Embedde...

Страница 6: ...ork Global Variant LTE Cat M1 2100 B1 1900 B2 1800 B3 AWS 1700 B4 850 B5 B26 900 B8 700 B12 B13 B28 800 B18 B19 B20 MHz GSM GPRS 850 900 1800 1900 MHz Data Support SMS UDP Packet Data Satellite Locati...

Страница 7: ...ns Industry Certifications FCC IC PTCRB CE RED CE SAFETY Applicable Carriers Device Management PULS Monitor manage upgrade firmware configure and troubleshoot devices remotely Embedded Intelligence En...

Страница 8: ...H 50 C non condensing Shock and Vibration U S Military Standards 202G 810F SAEJ1455 ESD IEC 61000 4 2 4KV Test Ingress Protection IP65 CalAmp Assembled Physical Design Dimensions 3 50 x 1 97 x 0 75 89...

Страница 9: ...he form fit and function when compared to the predecessor product line This section highlights pertinent changes compared to the LMU32 platform to help users get started with an EdgeCore device 4 1The...

Страница 10: ...e to third parties without express permission is strictly prohibited 2020 CalAmp 10 of 35 LMU 1300 Training Guide Revision Date 0 8 09 22 2020 Accessing Serial Port After installing the quectel driver...

Страница 11: ...n also be utilized For example the command tail F var log messages grep VBU will display lines in the log that have VBU in the string Important Note The log file stored in messages gets overwritten on...

Страница 12: ...LMU Binary bin c VBU dnld_cli prog_file 25 0 VBU Binary File bin d BLE dnld_cli prog_file 26 0 BLE Binary File bin 2 Option 2 Using AT Console Change the file name to update to ota_file bin a PEG2 at...

Страница 13: ...content of each file section Tags are used to identify the start of each section Header TAG Definition Example TD UTC Date and Time the file was generated or uploaded to the maintenance server PULS S...

Страница 14: ...replaced with custom names or named sub routines SCR L512000 T1 0 A51 512225 L512001 T2 0 A51 512225 L512002 T3 0 C39 7 A51 512185 L512003 T5 2 A51 512185 L512004 T11 0 C17 15 A31 15 L512005 T18 5 C1...

Страница 15: ...e line T TrigCode Mod0 T TrigCode Mod0 T18 0 T17 A8 4 C Conditi on Define one or more Conditions on the same line C CondCode Mod0 C CondCode Mod0 T13 C16 11 C16 10 C16 12 A 1 24 A Action Defines one o...

Страница 16: ...copy accumulator See below for a few examples of how multiple modifiers can be utilized in a PEG2 script Trigger Cond Action Definition Modifier 0 Modifier 1 Update End Trigger Code 61 An update has c...

Страница 17: ...2 conversion export feature so that an existing PEG1 script can be easily converted into a PEG2 script to avoid the need of re writing an existing script Note A PEG1 PEG2 conversation does not optimiz...

Страница 18: ...de Revision Date 0 8 09 22 2020 Note A more detailed step by step PEG1 PEG2 conversion user guide can be made available 5 6PEG2 Native Editor The latest LMU Manager also offers a way to create or edit...

Страница 19: ...s without express permission is strictly prohibited 2020 CalAmp 19 of 35 LMU 1300 Training Guide Revision Date 0 8 09 22 2020 PEG2 Readable Text To switch from PEG2 ASCII to readable text you can togg...

Страница 20: ...5 Input 6 Input 7 Input 8 Input 9 Input 10 Input 11 Input 12 Input 13 Input 14 Pure Virt Ign Pure Virt Ign Input 15 Input 16 N A Motion Wake Input 17 Input 18 N A Power State Wake Input 19 Input 20 In...

Страница 21: ...st parameters each individual parameter is polled every 450ms The LMU 1300 is different in that in between each registered non broadcast PID the device polls for SPEED and RPM increasing the polling i...

Страница 22: ...ting any PEG line number exceeding 253 255 still representing a Real Time PEG Action request 6 6Remote Debug PEG Action Unlike the LMU32 platforms EdgeCore LMU 1300 is always logging at a default leve...

Страница 23: ...es No Boot Reason 4 Wake Due to I O Activity Yes Yes Boot Reason 5 Wake Due To Timer Yes Yes Boot Reason 6 Wake Due to An Incoming SMS Message Yes Yes Boot Reason 7 Wake Due to Application Restart Yes...

Страница 24: ...This causes the motion log buffer to fill up faster The Short Motion Logs Types are defined on Calamp s wiki site https puls calamp com wiki Accelerometer_App_Note Long_Type_0_ 28Record_Type_1 29 6 13...

Страница 25: ...xternal facing official Version e g 1 5 4 b CANDIDATE is used to address bugs and minor changes Also external facing 1 5 4 9 c REVISION number displays the amount of commits and is used by the develop...

Страница 26: ...es to the LMU are not bent or constricted in any way Also make sure that the LMU is kept free from direct exposure to the elements sun heat rain moisture etc Be advised that an installation that viola...

Страница 27: ...to be able to view the LEDs periodically to make sure that the LMU is operating properly If at any time you should encounter a problem with the LMU you may need to read the LEDs in order to troublesh...

Страница 28: ...be fuse protected to not more than 5 Amps for 12VDC or 2 5 Amps for 24VDC The ignition input white wire must be connected to the vehicle ignition or another appropriate key operated line such as ACCE...

Страница 29: ...0 has been acquired and has registered to the wireless network Comm may be verified using an AT Command ATIC Depending on the wireless network being used something similar to what is shown below will...

Страница 30: ...ED is not visible then GPS service may be verified using an AT Command AT APP GPS The response should be similar to Lat 3304713 Lon 11727730 Alt 0 Hdg 113 Spd 0 3D RTIME HDOP 130 nSats 7 Installers ar...

Страница 31: ...t GPS location with the following command AT APP PEG ACTION 44 255 The LMU 1300 will respond with OK The backend monitor must then be contacted to confirm that they received an Event Report with Event...

Страница 32: ...s that only the Maintenance socket is ready A indicates no sockets are ready o a A This field indicates if the LMU has received an Acknowledgement from the Inbound server This field will be empty if t...

Страница 33: ...hat the LMU has or had a valid GPS solution The Sat Count field indicates how many GPS satellites are currently in use by the LMU The FixStatus field indicates the type of fix The Fix Status types are...

Страница 34: ...interference received including interference that may cause undesired operation FCC CFR 47 15 21 Caution any changes or modifications to this device not expressly approved by CalAmp could void the use...

Страница 35: ...cause undesired operation of the device Ce dispositif contient les metteurs r cepteurs autoriser exempts qui sont conformes au permis RSS exempt du Canada d innovation de la Science et de d veloppemen...

Отзывы: