Safety Summary

To avoid personal injury and/or product damage, review and comply 

with the following safety precautions. These precautions apply to both 

operating and maintenance personnel and must be followed during all 

phases of operation, service, and repair of this probe.

WARNING

 statement calls attention to an operating procedure, 

practice, or condition, which, if not followed correctly, could result in 

injury or death to personnel.

CAUTION

 statement calls attention to an operating procedure, 

practice, or condition, which, if not followed correctly, could result in 

damage to or destruction of parts or the entire product. 

Do Not Work Alone

Do not work alone when working with high voltages.

Inspect the Probe

Inspect the probe and accessories for cracks and frayed or broken 

leads before each use. If defects or damages are noted, DO NOT USE 

the probe.

Dry Conditions

Hands, shoes, floor and work bench must be dry. Avoid making 

measurements under humidity, dampness or other environmental 

conditions that might affect safety.

Do Not Remove the Probe’s Casing

Removal of the probe’s casing may expose you to electric shock. 

If necessary, disconnect the inputs and outputs of the probe before 

opening the case.

Hazardous Contact

To avoid injury, remove jewelry such as rings, watches, and other 

metallic objects. Do not touch exposed connections and components 

when power is present.

Unexpected Charges

Hazardous voltages may be present in unexpected locations in circuitry 

being tested when a fault condition in the circuit exists. Capacitors 

Содержание CT3684

Страница 1: ...CT3684 CT3685 User Manual...

Страница 2: ...ot work alone when working with high voltages Inspect the Probe Inspect the probe and accessories for cracks and frayed or broken leads before each use If defects or damages are noted DO NOT USE the p...

Страница 3: ...for Critical Applications This probe is not authorized for use in contact with the human body or for use as a component in a life support device or system Do Not Substitute Parts Do not install subst...

Страница 4: ...or measurements in circuits of installation CAT III it should incorporate the use of fused test probes Compliance Statements Disposal of Old Electrical Electronic Equipment Applicable in the European...

Страница 5: ...on mode CT3684 z z Up to 1400 V DC AC peak common mode CT3685 z z Attenuation settings of 10x CT3684 and 100x CT3685 z z High accuracy 1 z z High CMRR z z Power indicator LED z z 9 VDC adapter CT3723...

Страница 6: ...uct Description 2 1 CT3684 CT3685 Description Output BNC cable 90 cm with 4 mm Banana Plug Ground Lead Hook Probes Probe Body Power On Off Switch LED Power Indicator Leads 50 cm Figure 1 Front Panel D...

Страница 7: ...Optional Battery Pack If using the optional battery pack CT3729 the batteries supplied must be inserted into the battery pack and the pack attached to the probe See Figure 2 Figure 2 Replacing the Bat...

Страница 8: ...example 7 A wave matching the test signal should display on the screen of the oscilloscope and this means this probe is working properly 3 4 Getting Started 1 Connect the hook probes to the leads 2 C...

Страница 9: ...84 and 100 V div for the 100x probe CT3685 See Table 1 Vertical Scale on Oscilloscope Scope Input Impedance Probe Attenuation Setting Actual Attenuation Setting Vertical Scale Reading on the Oscillosc...

Страница 10: ...ge DC AC peak 70 V 700 V Maximum Common Mode Input Voltage DC AC peak 700 V 1400 V Absolute Maximum Rated Input Voltage each side to ground 500 Vrms CAT I 1000 Vrms CAT II Input Impedance 1 6 M 7 pF e...

Страница 11: ...s IEC 61010 031 CAT I CT3684 CATII CT3685 Specifications are subject to change without notice To ensure the most current version of this manual please download the current version from our website cal...

Страница 12: ...ersons will not be covered by this warranty Cal Test Electronics reserves the right to discontinue models change specifications price or design of this device at any time without notice and without in...

Страница 13: ...800 572 1028 caltestelectronics com 12...

Страница 14: ...800 572 1028 caltestelectronics com 13...

Страница 15: ...800 572 1028 caltestelectronics com 14...

Страница 16: ...2016 Cal Test Electronics Part 450844 001 20161222...

Отзывы: