P4, P5, and P6 Barbecue Grills
LTR50001137, Rev. Q
Appendix
www.calflamebbq.com
33
d.
Screw on the correct orifice for your grill until
it is finger tight.
e.
Tighten the orifice with the wrench.
f.
If you have dual infrared burners, repeat the
previous steps for the second burner.
g. Replace the back cover.
You will need:
•
Either a 13mm or 10mm open end wrench
•
One #50 orifice (for single infrared burner)
OR
•
Two #54 orifices (for dual infrared burners)
OR
•
One #52 orifice (for single infrared burner)
•
Pipe compound suitable for natural gas
You will need:
•
7mm wrench, socket, or nut driver
•
One or two 1.75mm orifices (depending on
your side burner)
•
Pipe compound suitable for natural gas
a.
Remove the grate, burner cap and burner
diffuser from the side burner.
b. Using a 7mm wrench, remove the orifice for
the burner.
c.
Apply a small amount of pipe compound to
the orifice threads.
d.
Screw in the orifice until it is finger tight.
e.
Tighten the orifice with the 7mm wrench.
f.
If you have dual side burners, repeat the
previous steps for the second burner.
4 . Mark the rating plate
After conversion has been completed, mark the rating
plate as NG with an indelible marker.
2 .
Replace the infrared burner orifices
a.
Unscrew the back cover from the grill and lift
it up and under the grill hood.
b. Using a wrench, remove the orifice for the
infrared burner.
c.
Apply pipe compound to the fitting threads
where you will place the new orifice.
3 .
Replace the side burner orifices