6
Installation /
Assemb
ly
Fireplace Owner’s Manual
LTR50001006, Rev. G
www.calflamebbq.com
Placement and Location
Cal Flame fireplaces are designed for
outdoor use only .
•
Never locate this appliance in a building, garage, or any other en-
closed room or under a sealed overhead structure, or in any type
of enclosed area such as a garage, shed, or breezeway. Keep clear
of trees and shrubs.
• Do not place fireplace under or near windows or vents that can be
opened into your home.
• Maintain sufficient distance as to not overheat any overhead com
-
bustible material such as a patio cover.
• The area surrounding your fireplace should be kept clean and free
from flammable liquids and other combustible materials such as
mops, rags or brooms, as well as solvents, cleaning fluids, and
gasoline.
• Do not block the vents located near the base of your fireplace as
gas may build up in case of leak and cause serious damage.
• Do not install or operate your fireplace in such a manner that the
cross ventilation openings are blocked. Fresh air must be able to
pass though installed vents to safeguard against residual gas ac-
cumulation. Failure to allow proper ventilation may cause fire or
explosion.
•
Do not locate appliance where it can get excessively wet. Do not
use this appliance if any part has been underwater. Immediately
call a qualified service technician to inspect the unit and to replace
any part of the control system and any gas control which has been
underwater.
• Place your fireplace on a flat and stable surface in an outdoor loca
-
tion such as a patio deck.
• Locate your fireplace adjacent to the gas supply line (liquid pro
-
pane or NG), preferably with the shortest gas line run possible.
•
Maintain the following clearances to combustible materials on all
Cal Flame fireplaces.
Sides and back
48 inches (122 cm) (measured from side)
Top
120 inches (305 cm) (measured from hearth)