Serial
Port
Configuration
Page
|
40
Figure
23
Internal
Serial
Port
Configuration
Page
8.2.1
SERIAL
PORT
CONFIGURATION
Baud
Rate:
Sets
the
baud
rate
of
the
serial
port.
Settings
may
range
from
300
to
115,200
bits
per
second.
The
default
baud
rate
is
115,200
bps.
8.2.2
PAD
SETTINGS
Remote
IP
Address:
Sets
the
IP
address
of
the
device
using
the
PAD
functionality.
Remote
Port:
Sets
the
port
number
used
by
the
remote
device
to
accept
requests
from
the
LandCell.
Local
Port:
Sets
the
port
number
used
by
the
LandCell
to
accept
requests
from
the
remote
device.
PAD
Mode:
Select
buttons
to
set
the
PAD
mode
of
the
LandCell
as
a
Server
or
Client.
Pad
Protocol:
Sets
the
data
protocol
of
the
PAD
to
TCP
or
UDP
data.
TCP
Client
Keep
Alive:
When
in
client
mode
and
enabled,
TCP
Keep
Alive
packets
will
be
sent
from
the
client
to
the
server
periodically
in
order
to
detect
a
broken
connection.
The
modem
will
automatically
try
to
re
‐
establish
the
connection
if
necessary.