3. Specifications
Current Draw
Amps
Low
0.06
Medium
0.11
High
0.21
Fan Speed
0.12
0.22
0.35
24 Volt
12 Volt
12
& 24
Volt
RPM
1
1
00 ±100
1
4
00 ±100
1
7
00 ±100
Maximum Airflow: 140 CFM (Cubic Feet Per Minute)
23
8
m³/h (Cubic Meters per Hour)
ii
i
.
Timer
This fan is equipped with a timer feature that allows you to set a
running time of 3, 6, 9 or 12 hours.
To set timer, press Timer Button 1, 2, 3 or 4 times. The LED bar will
light up beside selected time and fan will shut off when the timer
setting expires.
To turn the fan off mid timer, press the Timer Button until the LED
bars disappear, and then press the Power/Speed button to turn the fan
off.
4. Care and Maintenance
The Sirocco II requires very little maintenance. By following the
instructions within this manual, the fan will operate problem-free for
years. Turn power off to clean. A vacuum can be used to clear the fan of
any dust build-up and a dry cloth may be used to wipe the surface. Do not
use gasoline, thinner or other harsh chemicals to clean fan.
LED Timer Bars
Содержание Sirocco II 7010CAWBX
Страница 2: ......