10. HANDLING AND TRANSPORT 

The   machine   can   only   be   handled   with   the   suction   and   delivery   piping   disconnected   and   with   the   power   supply   

motor   still   or   disconnected.   

The   machines   installed   on   frame   can   be   handled   with   lifting   appliances   that   can   be   connected   to   the   lifting   hook   

envisioned   on   the   same   machine,   using   suitable   safety   systems.   

 

 

    

 

   

   

The   machine   must   be   transported   in   horizontal   position   and   in   optimal   safety   conditions.   

Lift   the   unit   using   only   the   lifting   points.   

Before   handling   the   machine,   check   dimensions   and   weights   on   the   plate.   

Do   not   stand   within   the   action   range   during   handling   of   the   machine.      

During    the    start-­‐up    and    maintenance    interventions,    envision    a    safe    transport    of    all    components    using   

appropriate    harness.    Handling    must    be    carried    out    by    specialised    staff    to    avoid    damaging    the    machine    and   

causing   accidents   to   staff.      

The    lifting    points    of    the    various    components    must    only    be    used    to    lift    the    components    for    which    they    were   

supplied.   

Do   not   stand   or   transit   underneath   and   near-­‐by   the   machine   when   it   is   lifted   from   the   ground.   

To   anchor   the   machine   to   the   transport   surface,   block   the   same   using   ropes   or   chains.   

N.B.   No   additional   accessory   can   be   connected   to   the   motor   pump   or   electric   pump   unit   during   the   lifting   or   

the   handling.   

   

   

   

11. STORAGE 

In   case   of   storage,   arrange   the   machine   in   a   closed   place;   if   left   in   the   open,   cover   it   with   a   waterproof   lining.   

Avoid   humidity   accumulating   around   the   machine.   Do   not   leave   the   pump   body   full   of   liquid.   Drain   it   through   

appropriate    drain    plug.    The    liquid    may    freeze    during    the    winter    months    and    damage    the    system.    When    the   

liquid   is   dangerous,   take   all   necessary   precautions   before   draining   the   tank   to   prevent   damages   and   accidents.   

Periodically   start   the   pump   for   a   few   seconds   to   avoid   scaling   inside   the   same   pump.      

 

 

 

 

 

 

 

 

 

 

Содержание Libellula 1/3" Series

Страница 1: ...EN USE AND MAINTENANCE INSTRUCTIONS SELF PRIMING DIAPHRAGM PUMPS LIBELLULA 1 3 SERIES Read this user manual before installing operating using and maintaining this equipment www caffinipumps it GB...

Страница 2: ...OPERATE THE PUMP UNTIL YOU HAVE READ AND UNDERSTOOD THIS MANUAL CAFFINI PUMPS DECLINES ALL AND EVERY LIABILITY FOR DAMAGE DUE TO NEGLIGENCE AND FAILURE TO COMPLY WITH THE INSTRUCTIONS IN THIS MANUAL...

Страница 3: ...NG AND TRANSPORT 9 11 STORAGE 9 12 INSTALLATION 10 13 BEFORE START UP 11 14 MAINTENANCE 12 15 SPARE PARTS 13 16 DISPOSAL 13 17 OPERATING PROBLEMS CAUSES AND SOLUTIONS 14 18 FEATURES 15 1 PRESENTATION...

Страница 4: ...ed on appropriate plate or punched near the oil introduction plug and the serial and or series number All our products have a 12 month warranty starting from the commissioning date and however for not...

Страница 5: ...rs of work The reducer connecting the engine to the connecting rod handle system can be made of light aluminium alloy or in cast iron The transmission gears can be straight or helical teeth with drive...

Страница 6: ...DED USE The pump is suitable for handling liquids or muds with solid parts in suspension The pump has dry functioning possibility at indeterminate time The Libellula 1 3 can also be suitable for the t...

Страница 7: ...lative distribution of measurement in time and in frequency of the acoustic pressure level of the Libellula 1 3 pump for every required soundproofing intervention 8 SAFETY AND ACCIDENT PREVENTION IMPO...

Страница 8: ...It is forbidden to stand under the loads It is forbidden to remove the ATTENTION Safety protections Do not open with the engine running INSTRUCTION FOR THE USE AND MAINTENANCE LIBELLULA 1 3 SERIES ve...

Страница 9: ...riate harness Handling must be carried out by specialised staff to avoid damaging the machine and causing accidents to staff The lifting points of the various components must only be used to lift the...

Страница 10: ...ted by ball or shutter valve Ensure all joints are perfectly air sealed check the threads the gaskets of the adapters of the ports and of the quick couplings Install the pump as close as possible to t...

Страница 11: ...turns in one direction or the other The incorrect rotation direction causes a significant reduction of the flow rate and an incorrect functioning of the reducer The correct rotation direction is that...

Страница 12: ...hrough the refuelling plug rod Every three months check the diaphragm and the valves for wear During the winter period with the machine still protect the pump from freezing drain any liquids from insi...

Страница 13: ...that facilitates correct installation Spring connecting rod In case of repairing the connecting rod item 218L540I ensure the total length of the same is 305 mm Other spare parts To replace other part...

Страница 14: ...suction filter 6 Remove the solid body Low flow rate 1 The rotation speed is too low 2 The delivery pipe is undersized or blocked 3 Too many curves or delivery pipe too long 4 Use of non reinforced c...

Страница 15: ...x352x614 mm Net weight 36 kg 79 kg PUMP Type Self priming diaphragm with self lubricated spring or rigid connecting rod Suction ports diameter 3 BSP or DN80 PN10 Delivery ports diameter 3 BSP or DN80...

Страница 16: ...CAFFINI CIPRIANO S r l 43044 LEMIGNANO DI COLLECCHIO Parma ITALY Via G Di Vittorio 46 Tel 39 0521 804325 Fax 39 0521 804145 info caffinipumps it w w w c a f f i n i p u m p s i t...