Cafe QuietBoost Blower CVW9304 Скачать руководство пользователя страница 6

49-2000706   Rev. 4

5

Controls

USING THE HOOD:

 Controls / Chef Connect

Chef Connect Operation Bluetooth

®

 Connection

To pair with another device:

To start the pairing process on the hood, press and hold 
the 

Light 

button for 3 seconds. The backlight for all the 

icons will flash until the hood is paired with the range or 
other device. If the pairing is successful, the backlights of 
all buttons will flash simultaneously three times and then 
turn off. The hood lights and fan default sync setting will 
be activated.

It will time out after 2 minutes if the pairing is not 
completed, after which the pairing sequence will need to 
be restarted. 

To cancel pairing:

To cancel the pairing, hold the 

Light

 button down for 3 

seconds and then turn off the hood.

Default Sync Settings:

The factory default setting for the light will be the brightest. 

The factory default setting for the fan sync will be OFF.

The user can change the Default Sync Settings by 
pressing and holding the 

Med

 button for 3 seconds. 

This will enter the Default Settings Mode. Once in 
this mode, the backlights for all buttons will blink on/
off indefinitely and the fan and light will switch to the 
current Default Sync Setting, so the user knows what the 
current default value is. At this time, set the light and fan 
to the desired default levels. Once the user is satisfied 
with the selection, press and hold the 

Power

 button 

for 3 seconds. This will exit this mode. At that time the 
backlights will stop blinking and the state of the fan and 
light will change back to their prior state before entering 
the Default Settings Mode. 

Chef Connect

1. Rangehood 

Control 

Panel: 

The control panel 

is located under the front edge of the canopy. The 
position and function of each control button are 
noted below.

2. Fan 

On/Off:

 

On/Off switch for the fan. The fan 

can be operated by pressing any of the fan setting 
buttons. Hold 

Power

 for 3 seconds to activate Delay 

Off feature, which automatically turns the fan off after 
15 minutes. Low, Med and High buttons LEDs will 
rolling blink to indicate Delay Off feature is activated.

3. Fan 

Settings: 

Speed control for fan. Fan 

speed is powered by 

QuietBoost™ Technology. 

This unique technology is designed to minimize 
ventilation noise and enhance motor efficiency for a 
peacefully-quiet, odor-free kitchen. Press the button 

Low

 for LOW speed, 

Med

 for MEDIUM speed, and 

High

 for HIGH speed. Hold down the High button 

for 3 seconds to activate the Boost speed that will 
run for 15 minutes. High button LED will blink on/off 
to indicate Boost feature is activated. 

4.   Light: 

Off/On/Night Light switch for the LED lights. 

Press the 

Light

 button to turn the lights on, again to 

set the lights to night light setting, and again to turn 
the lights off.

5.   Chef Connect: 

This is a Bluetooth

®

 pairing feature 

for use with other compatible Chef Connect enabled 
products on a cooktop or range. When the device is 
paired, the default sync settings will be activated upon 
receiving a command from the range or cooktop. To 
change the default sync setting, refer to the Chef 
Connect section. 

 

To pair devices, hold down the 

Light

 button for 3 

seconds. To turn it back off, hold the button down for 
another 3 seconds. See the Chef Connect section for 
more details.

6.   IR Sensor: 

Remote control receiver when used 

with remote control kit.

7.   Wi-Fi: 

Hold down the Low button for 3 seconds 

to initiate the Wi-Fi connection. The Wi-Fi indicator 
light turns on when connected, see the Wi-Fi 
Connect section for details.

2ႇ

Low

Med

Fan Settings

High

Light

Chef Connect

To Pair

Hold 3 Sec

Boost

Hold 3 Sec

WiFi

Pairing

Delay O

Hold 3 Sec

WiFi

1

6

2

4

5

7

3

Содержание QuietBoost Blower CVW9304

Страница 1: ...Owner s Manual...

Страница 2: ...Contents Safety Information 3 Using the Hood Controls 5 Chef Connect 5 Wi Fi Connect 6 Care And Cleaning Filter 7 Surfaces 8 Lights 8 Installation Instructions 9 Troubleshooting Tips 25 Limited Warran...

Страница 3: ...ill too Among other things registration of your appliance ensures that we can deliver important product information and warranty details when you need them Register your Caf appliance now online Helpf...

Страница 4: ...O PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING A SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the...

Страница 5: ...combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guidelines and safety standards such as those...

Страница 6: ...ion and function of each control button are noted below 2 Fan On Off On Off switch for the fan The fan can be operated by pressing any of the fan setting buttons Hold Power for 3 seconds to activate D...

Страница 7: ...ppliances com connect to learn more about connected appliance features and to download the appropriate app 2 Follow the app onscreen instructions to connect your Caf hood 3 Once the process is comple...

Страница 8: ...rinse in clean water or wash it in the dishwasher Do not use abrasive cleansers NOTE Some discoloration of the filter may occur in the dishwasher To clean hard to reach areas of the filter use a soft...

Страница 9: ...either side of the motor using three screws per side 3 Insert the tab on the charcoal filter into the triangular slot on the mount 4 Clip the charcoal filter in until it is locked 5 Repeat with second...

Страница 10: ...as a tag to the service panel CAUTION Due to the weight and size of these vent hoods and to reduce the risk of personal injury or damage to the product TWO PEOPLE ARE REQUIRED FOR PROPER INSTALLATION...

Страница 11: ...10 49 2000706 Rev 4 Installation Preparation INSTALLATION PREPARATION PRODUCT DIMENSIONS 30 Models Requires a 30 opening 36 Models Requires a 36 opening 18 12 1 4 21 36 18 21 30 12 1 4...

Страница 12: ...IED FOR INSTALLATION 1 Hardware Package 1 Literature Package 1 Installation Template PARTS NEEDED FOR INSTALLATION 1 Strain Relief 1 Wall or Roof Cap for vented installation only All Metal Ductwork WA...

Страница 13: ...rip Trays Motor Hood Body Metal Installation Bracket 2 Baffle Filters 3 with 36 models QTY 2 3 16 dry wall anchors with screws Used for hood bottom mounting screw holes Use 5 16 drill for pilot hole Q...

Страница 14: ...nted installations recirculation holes can be hidden by installing the upper duct cover upside down See table below for duct cover kit part numbers based on finish NOTE Duct Cover Kits CX8DC9SPDS and...

Страница 15: ...as Range Installation over Electric Range Ceiling Height ft in Recirc Installation Height Vented Installation Height Recirc holes hidden Recirc Installation Height Vented Installation Height Recirc ho...

Страница 16: ...or service representative if you are in doubt whether the appliance is properly grounded ADVANCE PLANNING Duct Install Planning This hood is designed to be vented vertically through the ceiling with...

Страница 17: ...r wall in the installation space FOR BACK VENTING RU GXFWHG LQVWDOODWLRQ WKURXJK WKH EDFN WKH 10 1 2 H x 13 1 4 W cut out for the duct in the wall must be centered in the installaton space left to rig...

Страница 18: ...f the soffit or cabinet For Ducting Through Rear Wall Note Check to make sure back damper will not interfere with studs electrical or plumbing before making cut out Back damper accessory UXBDA812 must...

Страница 19: ...emove shipping tape from damper and check that damper moves freely Install Top Damper The motor mounting plate comes pre installed in the hood for top venting Install the top damper to the hood body a...

Страница 20: ...INSTALLATION INSTRUCTIONS 4 Alternate Mounting Method INSTALL HOOD TO SOFFIT OR CABINET SKIP THIS STEP IF USING WALL MOUNTING METHOD IMPORTANT Soffit or cabinet framing must be capable of supporting...

Страница 21: ...opening Dim C to accommodate damper in back wall Drive mounting screws A into the studs until they protrude 1 4 This 1 4 gap will provide clearance to engage the keyhole slots in the top of the hood T...

Страница 22: ...copper connectors Remove junction box cover Pull the house wiring through the knockout at the top or back of the hood and secure with the strain relief Use UL listed wire nuts to connect incoming whit...

Страница 23: ...r damper operations Seal connection with tape only B Recirculation non vented Installation NOTE A recirculation duct WB34X30519 and Charcoal Filter UXCF91 are not included with the hood and are necess...

Страница 24: ...ollow instructions included with the duct cover accessory to install duct covers 9 INSTALL GREASE TRAYS AND FILTERS Remove protective film Place grease drip trays into slots Install the baffle filters...

Страница 25: ...modify the wiring as described below 1 Remove the baffle filters 2 Disconnect all the harnesses from the top of control box located on right side of motor 3 Loosen the screws on top of control box and...

Страница 26: ...han normal and or fan is making loud or abnormal airflow noise Obstructions in duct work Make sure nothing is blocking the vent Make sure your wall or roof cap has a blade or door Damper blade on wall...

Страница 27: ...arranty EXCLUSION OF IMPLIED WARRANTIES Your sole and exclusive remedy is product repair as provided in this Limited Warranty Any implied warranties including the implied warranties of merchantability...

Страница 28: ...inet Filler Panel Power Cord Kit Cleaning Supplies CitruShine Stainless Steel Wipes Stainless Steel Appliance Cleaner Bar Keepers Friend Soft Cleanser Looking For Something More Caf offers a variety o...

Страница 29: ...arn about special discounts that are available while your warranty is still in effect You can purchase it on line anytime Caf Service will still be there after your warranty expires In the US cafeappl...

Страница 30: ...EA Campanas para Cocina con Ventilaci n Con Extractor QuietBoost Modelos CVW9304 y CVW9364 Contenido Informaci n De Seguridad 3 Uso de la Campana Controles 5 Chef Connect 5 Conexi n Wi Fi 6 Cuidado y...

Страница 31: ...tro de su electrodom stico asegura que podamos entregarle informaci n importante del producto y detalles de la garant a cuando los necesite Registre su electrodom stico Caf ahora a trav s de Internet...

Страница 32: ...NCENDIO DE GRASA SOBRE UNA ESTUFA CUMPLA CON LOS SIGUIENTES PUNTOS A APAGUE LAS LLAMAS con una tapa que ajuste bien una plancha para galletas o una bandeja de metal y luego apague el quemador TENGA MU...

Страница 33: ...enea del equipo de consumo de combustible a fin de evitar r fagas de aire Siga las pautas del fabricante del equipo de calefacci n y los est ndares de seguridad tales como aquellos publicados por la A...

Страница 34: ...r de apagado del ventilador El ventilador puede ser usado presionando cualquiera de los botones de configuraci n del ventilador Mantenga presionado el bot n Power durante 3 segundos para activar la fu...

Страница 35: ...aci n para conectar su campana de Caf 3 Una vez completado el proceso la luz indicadora ubicada en la pantalla de la campana de Caf Appliances permanecer fija y la aplicaci n confirmar que usted est c...

Страница 36: ...entre en uso Para instalar Inserte la parte superior del deflector en el espacio detr s del panel de control Las flechas que est n al costado del deflector deber n apuntar hacia el frente de la unidad...

Страница 37: ...te la leng eta que se encuentra en el filtro de carb n dentro de la ranura triangular del montaje 4 Enganche el filtro de carb n hasta que quede bloqueado 5 Repita esto con el segundo filtro del otro...

Страница 38: ...roducto SE DEBER CONTAR CON DOS PERSONAS PARA UNA INSTALACI N ADECUADA ADVERTENCIA Desconecte toda la corriente el ctrica del disyuntor principal o de la caja de fusibles antes de la instalaci n ADVER...

Страница 39: ...6 Rev 4 PREPARACI N PARA LA INSTALACI N Preparaci n para la instalaci n DIMENSIONES DEL PRODUCTO Modelos de 30 Requiere una abertura de 30 Modelos de 36 Requiere una abertura de 36 18 12 1 4 21 36 18...

Страница 40: ...el producto o lesiones personales NOTA Antes de realizar cualquier corte o agujero para la instalaci n determine qu m todo de ventilaci n ser usado y con cuidado calcule todas las medidas HERRAMIENTAS...

Страница 41: ...modelos de 36 PAQUETE DE MATERIALES Ubique y controle los contenidos Cant 2 Anclajes para pared de yeso de 3 16 con tornillos Usados para los agujeros de los tornillos de montaje inferiores Use una b...

Страница 42: ...ra las instalaciones con ventilaci n los agujeros de recirculaci n podr n quedar ocultos instalando la tapa del conducto superior boca abajo Consulte en la siguiente tabla los n meros de piezas del ki...

Страница 43: ...na a Gas Instalaci n sobre Cocina El ctrica Altura del Cielorra so pies pulg Altura de Instalaci n con Recir culaci n Altura de Ins talaci n con Ventilaci n agujeros de recirculaci n ocultos Altura de...

Страница 44: ...a bien leer cuidadosamente ADVERTENCIA PARA SEGURIDAD PERSONAL ESTE APARATO DEBE CONECTARSE A TIERRA DE MANERA ADECUADA Quite el fusible o abra el interruptor de circuitos antes de comenzar la instal...

Страница 45: ...ed trasera terminada en el espacio de instalaci n PARA LA VENTILACI N INFERIOR Para una instalaci n con conducto a trav s de la parte trasera el espacio libre de 10 H x 13 W desde el conducto de la pa...

Страница 46: ...que el regulador trasero no interfiera con las vigas el sistema el ctrico o de plomer a antes de realizar el recorte El accesorio del regulador trasero UXBDA812 se deber adquirir de forma separada par...

Страница 47: ...e la pared se deber adquirir el accesorio del regulador UXBDA812 de forma separada Retire el panel cuadrado preperforado del cuerpo de la campana para la ventilaci n trasera Instale el regulador trase...

Страница 48: ...al del Espacio de Instalaci n 4 M todo Alternativo de Montaje INSTALE LA CAMPANA EN EL SOFITO O GABINETE SALTEE ESTE PASO SI USAR UN M TODO DE MONTAJE EN LA PARED IMPORTANTE El marco del sofito o gabi...

Страница 49: ...car el regulador en la pared trasera Conduzca los tornillos de montaje A por las vigas hasta que sobresalgan Esta brecha de brindar espacio libre para adherir las ranuras en la parte superior de la ca...

Страница 50: ...blero en la parte superior o trasera de la campana y asegure el mismo con un amortiguador de refuerzo Use tuercas para cables de la lista de UL para conectar los cables entrantes blanco con blanco y n...

Страница 51: ...ta nicamente B Instalaci n de la Recirculaci n no ventilada NOTA Un conducto de recirculaci n WB34X30519 y un Filtro de Carb n UXCF91 no se encuentran incluidos con la campana y son necesarios para la...

Страница 52: ...orio de la tapa del conducto para instalar las tapas de conducto 9 INSTALE LAS BANDEJAS Y FILTROS DE GRASA Retire la pel cula protectora Coloque las bandejas de goteo de grasa en las ranuras Instale l...

Страница 53: ...ntinuaci n 1 Retire los filtros de los deflectores 2 Desconecte todos los arneses de la caja de control superior ubicada sobre el lado derecho del motor 3 Afloje los tornillos sobre la parte superior...

Страница 54: ...anormal Obstrucciones en el conducto Verifique que no haya obstrucciones en la ventilaci n Controle que la cubierta de pared o casquete de techo tengan una hoja o puerta La hoja del regulador de tiro...

Страница 55: ...iminadas siguiendo las instrucciones de limpieza 6ROLFLWH HO VHUYLFLR WpFQLFR SDUD UHSDUDU R UHHPSOD DU ODV l mparas excepto las l mparas LED EXCLUSI N DE GARANT AS IMPL CITAS Su nica y exclusiva alte...

Страница 56: ...o de 15 Kit del Cable de Corriente Suministros de Limpieza Limpiadores de Acero Inoxidable CitriShine Limpiador para Electrodom sticos de Acero Inoxidable Bar Keepers Friend Soft Cleanser Busca Algo M...

Страница 57: ...ales que est n disponibles mientras su garant a a n est vigente La puede adquirir en cualquier momento a trav s de Internet Los servicios de Caf a n estar n all cuando su garant a caduque En EE UU caf...

Отзывы: