background image

CAEN

 

 

Electronic Instrumentation

 

 

DT55xxE Desktop HV Power Supply

 

16 

$CMD:MON,CH:XX,PAR:IMIN 

Min value of ISET 

$CMD:MON,CH:XX,PAR:ISDEC 

Decimal digits of ISET 

$CMD:MON,CH:XX,PAR:IMON 

IMON value 

$CMD:MON,CH:XX,PAR:IMRANGE 

IMON range (high /low) 

$CMD:MON,CH:XX,PAR:IMRESL 

IMON resolution in low range  

$CMD:MON,CH:XX,PAR:IMRESH 

IMON resolution in high range 

$CMD:MON,CH:XX,PAR:IMDECL 

Decimal digits of IMON in low range 

$CMD:MON,CH:XX,PAR:IMDECH 

Decimal digits of IMON in high range 

$CMD:MON,CH:XX,PAR:MAXV 

VMAX value 

$CMD:MON,CH:XX,PAR:MVMIN 

VMAX minimum value 

$CMD:MON,CH:XX,PAR:MVMAX 

VMAX maximum value 

$CMD:MON,CH:XX,PAR:MVRES 

VMAX resolution 

$CMD:MON,CH:XX,PAR:MVDEC 

Decimal digits of VMAX 

$CMD:MON,CH:XX,PAR:PDWN 

Power down mode Ramp / Kill 

$CMD:MON,CH:XX,PAR:POL 

Polarity 

$CMD:MON,CH:XX,PAR:STAT 

Status 

IS_ON                    

Channel On 

IS_UP                    

Channel Ramping Up 

IS_DOWN                  

Channel Ramping Down 

IS_OVC 

Channel in Overcurrent 

IS_OVV 

0x10 

Channel in OverVoltage 

IS_UNV 

0x20 

Channel in UnderVoltage 

IS_MAXV 

0x40 

Channel in MaxV 

IS_TRIP 

0x80 

Channel in Trip 

IS_MAXPW 

0x100 

Channel in MaxPower 

IS_TWARN 

0x200 

Channel in Temperature warning (>80°C) 

IS_OVT 

0x400 

Channel in OVT (>125°C) 

IS_KILL 

 

0x800 

Channel Killed 

IS_INTLCK    

0x1000 

Channel in Interlock 

$CMD:MON,CH:XX,PAR:RUP 

RAMP UP value 

$CMD:MON,CH:XX,PAR:RUPMIN 

RAMP UP minimum value 

$CMD:MON,CH:XX,PAR:RUPMAX 

RAMP UP maximum value 

$CMD:MON,CH:XX,PAR:RUPRES 

RAMP UP resolution 

$CMD:MON,CH:XX,PAR:RUPDEC 

Decimal digits of RAMP UP 

$CMD:MON,CH:XX,PAR:RDW 

RAMP DOWN value 

$CMD:MON,CH:XX,PAR:RDWMIN 

RAMP DOWN minimum value 

$CMD:MON,CH:XXPAR:RDWMAX 

RAMP DOWN maximum value 

$CMD:MON,CH:XX,PAR:RDWRES 

RAMP DOWN resolution 

$CMD:MON,CH:XX,PAR:RDWDEC 

Decimal digits of RAMP DOWN 

$CMD:MON,CH:XXPAR:TRIP 

Trip value 

$CMD:MON,CH:XX,PAR:TRIPMIN 

Trip minimum value 

$CMD:MON,CH:XX,PAR:TRIPMAX 

Trip maximum value 

$CMD:MON,CH:XX,PAR:TRIPRES 

Trip resolution 

$CMD:MON,CH:XX,PAR:TRIPDEC 

Decimal digits of Trip 

Set Commands 

$CMD:SET,CH:XX,PAR:VSET,VAL:XXX.XX 

VSET value 

$CMD:SET,CH:XX,PAR:ISET,VAL:XXXX.XX 

ISET value 

$CMD:SET,CH:XX,PAR:IMRANGE,VAL:LOW 

IMON range low 

$CMD:SET,CH:XX,PAR:IMRANGE,VAL:HIGH 

IMON range high 

$CMD:SET,CH:XX,PAR:RUP,VAL:XXX 

RAMP UP value 

$CMD:SET,CH:XX,PAR:RDW,VAL:XXX 

RAMP DOWN value 

$CMD:SET,CH:XX,PAR:PDWN,VAL:RAMP 

POWER DOWN ramp mode 

$CMD:SET,CH:XX,PAR:PDWN,VAL:KILL 

POWER DOWN kill mode 

$CMD:SET,CH:XX,PAR:ON 

Set Ch ON  

$CMD:SET,CH:XX,PAR:OFF 

Set Ch OFF  

 

Содержание DT5519EN

Страница 1: ...CAEN Tools for Discovery n Electronic Instrumentation Es DT55xxE Desktop HV Power Supply Rev 6 11 April 2017...

Страница 2: ...roduct is defective due to workmanship or materials and has not been caused by mishandling negligence on behalf of the User accident or any abnormal conditions or operations CAEN declines all responsi...

Страница 3: ...r 11 Power Supply Modules LabVIEW Instrument Driver 11 4 VT emulator control 12 Module access 12 Ethernet configuration 12 Firmware upgrade 13 Format EEPROM 14 Channels settings 14 Communication Proto...

Страница 4: ...EP 6 kV 1 mA 4 W Positive HV outputs are delivered through SHV connectors Mixed versions have two positive and two negative channels The HV output RAMP UP and RAMP DOWN rates may be selected independe...

Страница 5: ...cable 10BASE T Ethernet cable Power requirements The module is powered by the external AC DC stabilized power supply included in the delivered kit Switchbox Model FRA045 S12 4 see specifications in t...

Страница 6: ...3 F GHz plug and jack Test voltage 10kV DC 1mn unmated connectors Ratings 12kV DC 1mn mated pairs Current rating 10 A WARNING These connectors produce extremely hazardous high voltages at a potential...

Страница 7: ...trol panel NAME TYPE SIGNAL FUNCTION ALARM RED LED AMP 280371 2 Out Alarm status signalled active LOW INTERLOCK RED LED AMP 280371 2 In Interlock signal channels hardware disabled Alarm signal As an A...

Страница 8: ...FUNCTION 12V In RAPC722X SWITCHCRAFT PCB 2 1mm DC Power Jack Input 12V DC Input ON OFF switch Molveno A11331122000 A1 switch O power supply OFF I power supply ON IMON Range The channel current can be...

Страница 9: ...nA 2 of read 5nA 2 of read 500pA 2 of read 100nA 2 of read 50nA ISET vs IMON High range 2 of read 1 A 2 of read 50nA 2 of read 5nA 2 of read 1 A 2 of read 500nA Low range 2 of read 100nA 2 of read 5nA...

Страница 10: ...arts DT55xxE desktop power supply unit External AC DC power supply with separate power cord USB cable 10BASE T Ethernet cable Moreover an external PC is required supported OS Windows 7 or later Linux...

Страница 11: ...r level application such as GECO2020 and the lower layer software libraries For more info please visit www caen it products firmware software section Power Supply Modules LabVIEW Instrument Driver Pow...

Страница 12: ...k and set the virtual communication port associated to the module Select USB connection and the used port number set port as follows baud rate 9600 Data bits 8 Parity none stop bit 1 Flow control none...

Страница 13: ...in the EEPROM and go back to Main Menu the DHCP server will automatically assign a new IP to the module at next Power On Firmware upgrade To upgrade the firmware download from www caen it unit page th...

Страница 14: ...ded firmware Format EEPROM By typing F on Terminal Board Menu Fig 10 it is possible to access the format EEPROM menu Fig 12 Format EEPROM Menu Channels settings By typing D on Terminal Board Menu Fig...

Страница 15: ...0x1000 At least one ch in Interlock CMD MON PAR MACADDR Board MAC Address CMD MON PAR IPADDR Board IP Address CMD MON PAR SUBMASK Subnet mask CMD MON PAR GATEWAY Gateway CMD MON PAR DHCPEN DHCP Enable...

Страница 16: ...hannel in Temperature warning 80 C IS_OVT 0x400 Channel in OVT 125 C IS_KILL 0x800 Channel Killed IS_INTLCK 0x1000 Channel in Interlock CMD MON CH XX PAR RUP RAMP UP value CMD MON CH XX PAR RUPMIN RAM...

Страница 17: ...nge of customers including engineers scientists and technical professionals who all trust them to help achieve their goals faster and more effectively CAEN S p A CAEN GmbH CAEN Technologies Inc Via Ve...