Document type:
Title:
Revision date:
Revision:
User's Manual (MUT)
A3000NF 3Phase Notch Filter for A3486
18/06/2008
4
NPO:
Filename:
Number of pages:
Page:
00120/04:3000N.MUTx/04 A3000NF_REV4.DOC
13
12
WARNING: IN ORDER TO PROVIDE PROPER AIR FLOW, REMEMBER TO
LEAVE A ~1” (2.54cm) AT LEAST FREE SPACE ABOVE THE MODULE’S UPPER
PANEL, WHEN MOUNTED IN THE RACK.
2.2.4 AC
source
The Mod. A3000NF ACsource is as follows:
The input voltage range and current required is specified in § 1.4. Ensure that under
heavy load, the AC voltage supplied to the unit does not fall below the specifications
described in § 1.4.
2.2.5
3-phase power supply cable
The power supply cable to be connected to the IN connector (see § 1.6) is configured as
follows (see also figure):
EARTH : green-yellow cable
L1: black cables N°1 & N°2
L2: black cables N°3 & N°4
L3: black cables N°5 & N°6
Connector type:
Harting 09.12.007.3101
Hood:
Harting 19.20.003.1440
Contacts:
Harting 09.15.000.6201
Coding pin Female:
Harting 09.12.000.9902
Cable:
113408 LTZE-Superfelx PLUS-N-PUR suitable to 15A@400V