Caen A1539 Скачать руководство пользователя страница 2

 

 

Purpose of this Manual 

This document is the  A1539, AG539, A154X, AG54X  Power Supply Boards manual; it contains information about the 
installation, the configuration and the use of the board. 

Change Document Record 

Date 

Revision 

Changes 

25 November 2013 

PRELIMINARY Release 

5 December 2014 

Updated with dual range versions 

6 May 2015 

Updated Technical specifications 

 

Symbols, abbreviated terms and notation 

T.B.D. 

Reference Documents 

 

Disclaimer 

No  part  of  this  manual  may  be  reproduced  in  any  form  or  by  any  means,  electronic,  mechanical,  recording,  or 
otherwise, without the prior written permission of CAEN SpA.  

CAEN  will  repair  or  replace  any  product  within  the  guarantee  period  if  the  Guarantor  declares  that  the  product  is 
defective due to workmanship or materials and has not been caused by mishandling, negligence on behalf of the User, 
accident or any abnormal conditions or operations. 

CAEN declines all responsibility for damages or injuries caused by an improper use of the Modules due to negligence on 
behalf  of  the  User.  It  is  strongly  recommended  to  read  thoroughly  the  CAEN  User's  Manual  before  any  kind  of 
operation.

 CAEN reserves the right to change partially or entirely the contents of this Manual at any time and without 

giving any notice. 

Disposal of the Product

 The product must never be dumped in the Municipal Waste. Please check your local regulations 

for disposal of electronics products. 

Made In Italy

 : We stress the fact that all the boards are made in Italy because in this globalized world, where getting 

the lowest possible price for products sometimes translates into poor pay and working conditions for the people who 
make them, at least you know that who made your board was reasonably paid and worked in a safe environment. (this 
obviously applies only to the boards marked "Made in Italy", we cannot attest to the manufacturing process of "third 
party" boards). 

 

 

 

 

 

 

 

 

 

Содержание A1539

Страница 1: ...CAEN Tools for Discovery n Electronic Instrumentation Rev 0 Es A1539 AG539 A154X AG54X Power Supply Boards Rev 2 6 May 2015...

Страница 2: ...ccident or any abnormal conditions or operations CAEN declines all responsibility for damages or injuries caused by an improper use of the Modules due to negligence on behalf of the User It is strongl...

Страница 3: ...safety information 9 Injury Precautions 9 Safety Terms and Symbols on the Product 9 Installation 9 4 Operating modes 10 Output control and monitoring 10 Output Enable 11 Grounding specifications 12 Sa...

Страница 4: ...rs 24 channel SHV versions are double width boards 10 TE all other versions are single width 5 TE All boards are provided with both current and voltage protections If over current occurs the relevant...

Страница 5: ...nels 0 500 V common to all board channels VMAX hardware accuracy 1 V VMAX software 0 100 V settable for each channel 0 500 V settable for each channel VMAX software resolution 1 V Ramp Up Down 1 50 Vo...

Страница 6: ...single width 5 TE height is 6U External connections The function and electro mechanical specifications of the external connectors are listed in the following subsections Version 24 32 channel DB25 12...

Страница 7: ...ntation A1539 AG539 A154X AG54X Power Supply Boards 7 DB25 connector pin assignment Fig 2 DB25 connector pin assignment 32 channel version INT INT interlock RTN channel return AGND earth SH connector...

Страница 8: ...s VMAX trimmer Function it allows to adjust the hardware maximum voltage VMAX common to all the channels Its value can be read out via software Shield CFG jumpers 24 32 ch floating Function see table...

Страница 9: ...s To avoid electric shock or fire hazard do not operate this product with covers or panels removed Do Not Operate in Wet Damp Conditions To avoid electric shock do not operate this product in wet or d...

Страница 10: ...ameter shows the ON OFF channel status As this parameter is set ON the channel is switched on if the INTERLOCK is not active and if the channel is enabled either locally or remotely highlighted in gre...

Страница 11: ...r it is possible to monitor board parameters such as measured Temperature and HVMax and to check board status the following messages may be returned by the POWER SUPPLY SYSTEM when monitoring the boar...

Страница 12: ...is available as front panel 2mm socket connector This feature allows on detector grounding thus avoiding loops which may increase noise level FAGND and AGND may be coupled in several ways according to...

Страница 13: ...HV CABLE AGND 2 1 4 3 6 5 FRONT PANEL JUMPERS 1 HV Generator Load PMT 0 HV Channel 0 RETURN Load PMT 31 HV Channel 31 EARTH of DETECTOR Cable SHIELD Circuit Protected SHIELD Circuit Protected RETURN...

Страница 14: ...including engineers scientists and technical professionals who all trust them to help achieve their goals faster and more effectively CAEN S p A CAEN GmbH CAEN Technologies Inc Via Vetraia 11 Klingen...

Отзывы: