REGUL8OR – User’s Manual
27
1.10
Input Voltage and Current connectors
The output current and the output voltage are sensed by connectors placed on
the device rear panel. The current is measured with a proprietary DCCT supplied and
connected from/to a DSUB9 female connector. This cable is supplied together with the
REGUL8OR unit.
The voltage, on the other side, is voltage is sensed using two isolated banana
connectors.
Both current and voltage values are conditioned with two independent analog
and digital networks that can be configured to read different ranges so to optimize the
regulation performance on several types and ratings of external power stage or
programmable power supplies.