2.5
FAST-PS-1K5 Connections
For installation and connection instructions refer to FAST-PS-1K5 User’s
Manual, chapter 2.
2.6
FAST-PS-1K5 Configuration
FAST-PS-1K5 in standalone configuration has 100 W of negative power. Even
if dissipation unit is connected to main power converter 100 W limit is still active and
system will go in fault if this limit is exceeded. To achieve full current sinking capability
when using dissipative unit this option must be enabled in FAST-PS-1K5 configuration.
Power converters purchased together with F1K5-DISS dissipation unit have this option
already enabled by default.
To enable (or disable) full current sinking capability use FAST-PS-1K5’s web
server interface. Under
CONFIG
tab select
INTERNAL MEMORY
. Set Value of ID 54
(Dissipative enabled on AUX2 at start-up) to “1”. For more information on
configuration refer to Remote Control Manual.
Whenever changing this parameter FAST-PS-1K5 must be power-cycled for
new value to be valid.
2.7
Front Panel LED Indicator
The F1K5-DISS has front panel LED indicator as shown in the
Figure 3:
front panel indicator
The front panel indicator and its behaviour is outlined in the following table:
Color
Action
Meaning
GREEN
Blinking, LONG interval
Ready, not sinking any current
GREEN
Blinking, SHORT interval
Active, sinking current, below 1.000 W
ORANGE
Blinking, SHORT interval
Active, sinking current, above 1.000 W