TR-MAN-3NMB
Operator's Manual - 3NMB
Page 13 of 39
Cadman Power Equipment
▪
BOX 100, Courtland, Ontario, Canada N0J-1E0
▪
Phone: 519-688-2222
▪
Fax: 519-688-2100
▪
www.cadmanpower.com
Step 9
3. Adjust the nozzles for correct coverage
and to avoid excess overlap. This can be
done by three separate adjustments:
Figure 14 - Unreel Direction
img-00048
4. Adjust the sliding nozzle mount to
your needed width.
Figure 15 - Sliding Nozzle Adjustment
img-00049
5. Adjust the three-point hitch to your needed height
Figure 16 - 3-Point Hitch Adjustment
img-00051
OPERATOR NOTE
Each application may require
adjustment based on system
variables (e.g. solid content, pump
pressure, distance from source,
etc.). The following are guidelines to
aid in the set-up process
Maximum:
For Low (1-2%) Solid Content Fluid
and good operating pressure adjust
the nozzles to the maximum width.
img-00032
Medium:
For Medium (3-4%) Solid Content
Fluid and/or poor operating pressure
adjust the nozzles to a narrower
width.
img-00033
Minimum:
For High (5-6%) Solid Content Fluid
and/or poor operating pressure
adjust the nozzles to the narrowest
width.
img-00034
Please Note:
Variables such as system design,
pump capacity, 3-point hitch
limitations, and slurry constitution
may result in adjustments other than
shown in these guidelines.