background image

TAB

GRILL

Figure 7

Figure 6

Figure 8

The Com-Pak Plus

The Com-Pak Twin Plus

WARNING!
Warranty is void
if any material is
sprayed on the
element or blower.
Use paint mask
provided if walls
are to be textured
or painted.

WARNING!
Risk of Electrical
Shock. Connect
grounding lead to
grounding wire
provided. Keep all
foreign objects out
of heater.

WARNING!
Risk of Fire.
Heater must be
kept clear of all
obstructions: 3 feet
in front and above;
6 inches on both
sides minimum

WARNING!
Heaters must be kept
clean of lint, dirt and
debris. 

Failure to follow
warnings may
cause heater to
eject sparks, ignite
materials, or cause
electrical shock and
will void warranty.

WARNING!
TURN OFF POWER
AT THE CIRCUIT
PANEL OR FUSE
BOX BEFORE
ATTEMPTING ANY
MAINTENANCE.

Installation Instructions

Operation & Maintenance

Wiring Diagrams

How do I insert the heater
assembly into the wall can?

Turn heater assembly upside-down with motor facing
you. Connect the supply wires to the heater wires with
connectors (See Figure 6). Now rotate the heater so the
element and fan are facing you (with the element ‘up’).
Insert the bottom edge of the heater assembly into the
halfround slots in the bottom lip of the wall can (See
Figure 7). [IMPORTANT: Push wires into bottom of wall
can during insertion. As long as wires are not caught
behind motor, attach assembly at top with screw
provided.]
[IMPORTANT: Be sure that supply wires are not caught
between motor and wall can.] Secure heater assembly
with screw provided.

Install grill

Install grill with the screws provided. If you have a built-in
thermostat model, slide thermostat knob onto shaft. Turn
power on at the circuit panel or fuse box.

STEP 2

STEP 1

Install heater assembly

How to operate your heater

1.

Once installation is complete and power has been

restored, turn the thermostat knob fully clockwise.

2.

When the room reaches your comfort level, turn the

thermostat knob counterclockwise until the heater turns off.
The heater will automatically cycle around this preset
temperature.

3.

To reduce the room temperature, turn the knob

counterclockwise. To increase the room temperature, turn
the knob clockwise.

Maintenance
As needed or every six months minimum.
1.

TURN POWER OFF AT CIRCUIT PANEL OR FUSE BOX.

2.

Remove grill. Blow down through the element with

compressed air or a vacuum cleaner using the blow cycle.
Vacuum the debris out of the blower wheel. Clean and
reinstall grill.

3.

Turn power on at circuit panel or fuse box.

About the Heater Temperature-Limiting Controls

The heater is protected by two temperature-limiting
controls (for Model CT, four controls are used). The first is a

high temperature reset switch, designed to open the heater
circuit when excessive operating temperatures are
detected. 
Further protection is provided by a backup over-
temperature switch, which will open the heater circuit in
severe over-temperature conditions, or in the event of
component failure. If this occurs, the heater must be
replaced.      

Resetting the Manual-Reset Limit Control

If the manual-reset limit control has opened the heater
circuit due to excessive operating temperatures, the heater
will not work until the limit reset button is pressed. After
allowing the unit to cool for at least 10 minutes, use a
narrow object such as a ball-point pen to access the reset
button through the lower-left section of the heater grill.
Press GENTLY, and be sure to listen and feel for a click
indicating it has been reset.  

Note that resetting the manual limit control may not restore
heater operation if a severe over-temperature condition
has occurred. See the Troubleshooting Guide on page 4 for
more information.

Part Two

G

= Ground

T

= Thermostat

After you have followed all instructions in PART ONE for either new

construction or an existing wall, you are ready to install the heater assembly.

G

G

T

G

T

G

T

G

G

G

G

The Com-Pak Plus

The Com-Pak Twin Plus

Отзывы: