OPERATING INSTRUCTIONS
F
NO
NO
HEAT
A
A
NO FAN
NO HEAT
FAN
ONLY
SLEEP
HEAT
+
:$51,1*
Risk of Electrical Shock and Fire.
The heater must be properly installed before it is
used.
1. Do not operate without grill.
.HHSHOHFWULFDOFRUGVGUDSHU\IXUQLVKLQJVDQG
RWKHUFRPEXVWLEOHVDWOHDVWIHHWPDZD\
IURPWKHIURQWRIWKHKHDWHUDQGLQFKHV
cm) away from the sides.
'RQRWWDPSHUZLWKWKHRYHUWHPSHUDWXUHOLPLW
control.
4. If the heater over temperature limits trip more
WKDQRQFHSHUGD\WKHKHDWHUPXVWEHUHSODFHG
&OHDQKHDWHUDWOHDVWHYHU\VL[PRQWKV
$IWHUDOORZLQJWKHKHDWHUWRFRROWXUQSRZHURII
at circuit breaker panel before removing grill.
8VH D KDLU GU\HU RU YDFXXP RQ EORZ F\FOH
to blow debris through the top element (do not
touch element).
,QVWDOOWKHJULOOEHIRUHWXUQLQJRQSRZHU
:$51,1*
Any other service not detailed in
this Owner’s Guide should be performed by an
authorized service representative.
'LJLWDO'LVSOD\
&RQWURO%XWWRQV
+HDWHU0RGHV
6HWWLQJ'HDWLQJ7HPSHUDWXUH
3URJUDPPLQJ<RXU1LJKW$ZD\%XWWRQ
(QHUJ\6DYLQJ7LSV
• Set your Night/Away set point to as low as you are com-
IRUWDEOHIRUDFRROHUQLJKWWLPHWHPSHUDWXUH
•
:KHQ\RXH[LWWKHURRPRUOHDYH\RXUKRPHSXVKWKH1LJKW
button to drop the temperature set point.
• If your heater is positioned in a drafty area or exposed to
GLUHFWVXQOLJKWWHPSHUDWXUHUHDGLQJZLOOEHDIIHFWHG6HWWHP
-
SHUDWXUHWRGHVLUHGFRPIRUWOHYHOQRWD³QXPEHU´RQWKHGLJLWDO
display.
You can preset a night or away temperature
VHWSRLQWIRUTXLFNDQGHDV\³RQHWRXFK´
energy savings.
• Push rocker switch to HEAT mode.
• Push Night button to activate. The moon
icon will show in display screen. The “night/
DZD\´VHWSRLQWWHPSHUDWXUHZLOOÀDVKIRU
seconds.
• Push the Up or Down button to
change your desired night/away set point.
• To return to your previous HEAT set point
ZKHQ\RXDZDNHRUUHWXUQSXVKWKH1LJKW
DJDLQ7KHVHWSRLQWWHPSHUDWXUHZLOOÀDVK
IRUVHFRQGV7KHPRRQLFRQZLOOQRORQJHU
be in display screen.
• To return to your previous night/away set-
SRLQWVLPSO\SXVKWKH1LJKWEXWWRQ
8VLQJWKHURFNHUVZLWFK\RXFDQPRYHWKHVZLWFKWRWZRPRGHV
/()7326,7,21+($702'(
Your Com-Pak Energy Plus heater has a unique variable speed
blower that auto adjusts the heat output based on the room’s
requirements. Once you set the thermostat to your desired tem-
SHUDWXUHWKHKHDWHUZLOOYDU\WKHZDWWDJHRXWSXWIRUPD[LPXP
HI¿FLHQF\
The digital display will show the level of heat being output to
maintain the room’s temperature.
5,*+7326,7,21)$121/<02'(
The FAN ONLY mode can circulate air but will not supply heat.
Three fan speeds are available. To adjust the fan speed: With
URFNHUVZLWFKLQWKH5,*+7SRVLWLRQSXVK8SRU'RZQGLJ
-
LWDOEXWWRQV'LVSOD\ZLOOUHDG³´IRUORZVSHHG³´IRUPHGLXP
VSHHGRU³´IRUKLJKVSHHGGXULQJWKHVHWXSSURFHVVWKHQ
resume to temperature display.
• Push rocker switch to HEAT mode.
• Touch the up button or the down but-
ton to set your desired temperature.
7HPSHUDWXUH6HWSRLQW5DQJHÛ)Û)
Û&Û&
5RFNHU6ZLWFK
+HDWLQJ)XOHDWLQJ0LHDWLQJ/RZ3RZHU
)DQ2QO\1R+HDW
NIGHT /
AWAY
1LJKW$ZD\
%XWWRQ
1LJKW$ZD\0RGH
)DQ2SHUDWLRQ
)DKUHQKHLW6HWWLQJ
1LJKW$ZD\0RGH
,FRQ
3URSRHDW
&RQWURO,QGLFDWRU
+HDWLQJ
0RGH
,QGLFDWRU
7HPSHUDWXUH
)DQ0RGH
,QGLFDWRU
HEAT
FAN
ONLY
FAN
ONLY
HEAT
NIGHT /
AWAY
5RFNHU6ZLWFK
1LJKW%XWWRQ
'LJLWDO'LVSOD\
8S%XWWRQ
'RZQ%XWWRQ
8S
'RZQ
Page 6