DERXWWKH&DGHW(QHUJ\3OXVKHDWHU
VRPHLQVWDOODWLRQIDFWV
VRPHJHQHUDOWLSV
WKDWDZDOOWKHUPRVWDWLVQRWUHTXLUHG
7KH&DGHW(QHUJ\3OXV+HDWHUSURYLGHVZDUPWKDQGFRPIRUWWRDURRPE\XVLQJDQHI¿FLHQW
YDULDEOHVSHHGIDQWRFLUFXODWHWKHZDUPDLUDQGDQLQWHOOLJHQWWKHUPRVWDWWRGHOLYHUSUHFLVH
temperature control.
The Cadet Energy Plus heater is designed to save energy and run at a low speed and heat
output once the desired room temperature is reached. This is normal operation for maintaining
and regulating desired room temperature. This low speed fan movement also provides better
DLUPL[LQJZLWKLQWKHURRPDQGIHZHURQRIIF\FOHV
6DIHW\LV&DGHW¶V¿UVWSULRULW\$OOKHDWHUVIHDWXUHDKLJKWHPSHUDWXUHOLPLWVZLWFKWKDWVKXWVWKH
heater off when excessive operating temperatures are detected.
)RUHIIHFWLYHDQGVDIHRSHUDWLRQDQGWRSURORQJWKHOLIHRIWKHKHDWHUUHDGDOOLQVWUXFWLRQVDQG
VDIHW\LQIRUPDWLRQDQGIROORZWKHPDLQWHQDQFHLQVWUXFWLRQVLQWKLV2ZQHU¶V*XLGH
)RUQHZLQVWDOODWLRQ\RXVKRXOGEHSUHSDUHGWRUXQZLUHRUHOHFWULFDOFRQGXLWWR\RXUGHVLUHG
location for your heater.
$TXDOL¿HGRUGHGLFDWHGFLUFXLWIURPWKHPDLQGLVFRQQHFWSDQHOLVUHTXLUHG
$QLQZDOOHOHFWULFIDQKHDWHULVDSHUPDQHQWVDIHKDUGZLUHGVROXWLRQWKDWUHTXLUHVDFXWRXW
LQ\RXUZDOOWRUHFHVVWKHKHDWHUXQOHVVD&DGHWVXUIDFHPRXQWDGDSWHULVXVHG
• The Cadet Energy Plus heater must only be installed vertically in a wall.
7KHKHDWHUPXVWQRWEHLQVWDOOHGLQWKHÀRRURUFHLOLQJHYHQLI\RXDUHUHSODFLQJDQH[LVWLQJ
heater that was installed in either of these locations.
• Installation on an inside wall is recommended.
)RUEHWWHUFRPIRUWGRQRWLQVWDOOZKHUHDLULVOLNHO\WRFRQWLQXRXVO\EORZGLUHFWO\RQWR\RXRU
another person.
7KHUHFRPPHQGHGKHLJKWIURPWKHÀRRULVLQFKHVFPIRUHDV\DFFHVVWRWKHGLJLWDO
WKHUPRVWDW,WZLOOIXQFWLRQSURSHUO\LQORZHUSRVLWLRQVEXWPXVWQRWEHORZHUWKDQòLQFKHV
FPDERYHWKHÀRRU
• The Cadet Energy Plus heater must only be installed with a Com-Pak style wall can model
CC.
%HVXUHWKDW\RXUZDOOFDQLVPRXQWHGÀXVKZLWKWKHRXWVLGHRIWKHVKHHWURFN
7KHKHDWHUKDVDFRROGRZQIHDWXUHWKDWZLOOUXQWKHIDQIRUXSWRPLQXWHVDIWHUVZLWFKLQJWR
FAN ONLY mode or if set point is reached and mild outdoor temperatures create low demand.
7KLVLVQRUPDO7KHDLUEHLQJGLVFKDUJHGPD\IHHOFRROEXWLVDFWXDOO\URRPWHPSHUDWXUHUHVLGX
-
al heat moving into the room.
%HFDXVHWKHGLJLWDOWKHUPRVWDWLVEXLOWLQWKH(QHUJ\3OXVKHDWHULWLVYHU\LPSRUWDQWWRFRQ
-
GXFWSURSHUPDLQWHQDQFH6HH3DJHRIWKHKHDWHUWRPDLQWDLQSHDNSHUIRUPDQFHDQGVDIHW\
7KH&DGHW(QHUJ\3OXVKHDWHU¶VXQLTXHYDULDEOHVSHHGEORZHUZLOODXWRDGMXVWEDVHGRQWKH
URRPUHTXLUHPHQWVDQGKHDWRXWSXW,WZLOOTXLHWO\GHOLYHUKHDWDWDORZVSHHGIRURSWLPXPSHU
-
formance and energy savings once desired temperature setpoint is reached.
A wall thermostat may not be used to control this heater. The Energy Plus heater is equipped
with a unique built-in thermostat that both regulates the heater output and provides precise
WHPSHUDWXUHFRQWURO,IUHSODFLQJDKHDWHUFRQWUROOHGE\DQH[LVWLQJZDOOWKHUPRVWDWUHPRYHZDOO
thermostat from the heater circuit and cover hole with a faceplate.
725(029($1(;,67,1*:$//7+(50267$7)520+($7(5&,5&8,7
1. Make sure power is off at the main disconnect panel.
2. Remove wall thermostat mounting screws.
3XOOWKHWKHUPRVWDWDZD\IURPWKHZDOODQGFRXQWWKHZLUHV
$,I\RXFRXQWEODFNVXSSO\ZLUHVDQGZKLWHVXSSO\ZLUHVLQWKHER[GLVFRQQHFW
thermostat and connect the 2 black wires together with one wire connector (not included).
Connect the 2 white wires together with another wire connector (not included). Connect all
ground wires together.
%,I\RXKDYHEODFNVXSSO\ZLUHDQGZKLWHVXSSO\ZLUHGLVFRQQHFWWKHUPRVWDWDQG
connect the black and white wires together with a wire connector (not included). Connect
all ground wires together.
&,I\RXKDYHPRUHWKDQEODFNRUZKLWHZLUHVSOHDVHFRQVXOWDTXDOL¿HGHOHFWULFLDQ
,I\RXKDYHDPHWDOMXQFWLRQER[LWPXVWEHJURXQGHGXVHDJURXQGLQJVFUHZRUFOLS
6. Install a blank faceplate (not included) over the exposed junction box.