background image

CONSERVE ESTAS INSTRUCCIONES

cadetheat.com    Tel: 360-693-2505    PO Box 1675   Vancouver, WA    98668-1675

INSTRUCCIONES IMPORTANTES

Diagramas de cableado

CONTROL DEL 

TERMOSTATO

INTERRUPTOR LÍMITE 

DE ALTA TEMPERATURA 

DE REGLAJE MANUAL

MOTOR

INTERR. DE MODO

CALENTADOR AISLADO DE DESCONEXIÓN RÁPIDA

NEGRO

BLANCO
BLANCO

TERMISTOR

NEGRO

NEGRO

ROJO

ROJO

AMARILLO

AMARILLO

NEGRO

MARRÓN

NARANJO

CONECTOR

CANDADO 

DE 240 

VOLTIOS

CANDADO 

DE 120 

VOLTIOS

BLANCO

1   2    3   4

1   2    3   4

1   2    3   4

L1

L2 O N

      ADVERTENCIA

Al utilizar artefactos eléctricos, siempre se deben adoptar precauciones básicas para reducir el riesgo 

de incendios, electrocución y lesiones personales, incluyendo lo siguiente:

1. Lea todas las instrucciones antes de instalar o 

usar este calentador.

2.      

ADVERTENCIA

Riesgo de incendio. Este calentador se calienta 

mucho  cuando  está  en  uso.  Precaución  –  Alta 

temperatura.  Riesgo  de  incendio.  Mantenga  los 

cables  eléctricos,  cortinas,  muebles,  y  demás 

materiales combustibles a por lo menos 3 pies por 

delante y a 6 pulgadas por encima y por ambos 

costados del calentador.

3.      

ADVERTENCIA

Riesgo de quemaduras. Para evitar quemaduras, 

no  lo  toque  con  su  piel  descubierta.  Tenga 

mucho cuidado cuando algún tipo de calentador 

sea usado por o cerca de niños o de personas 

inválidas, y cada vez que lo deje funcionando sin 

vigilancia.

4.      

ADVERTENCIA

Riesgo  de  electrocución.  No  opere  ningún 

calentador  después  de  una  avería.  Desconecte 

la alimentación en el panel de servicio y pida a un 

técnico electricista calificado que lo revise antes 

de volver a usarlo.

5.      

ADVERTENCIA

No lo use a la intemperie.

6.  Para  desconectarlo,  ponga  los  controles  en 

OFF,  y  apague  la  alimentación  del  circuito  del 

calentador en el panel de desconexión principal.

7.      

ADVERTENCIA

Riesgo  de  electrocución.  No  introduzca  ni 

permita  que  ingresen  objetos  en  las  aberturas 

de  la  ventilación  o  escape,  ya  que  ello  puede 

causar electrocución o incendio, o bien dañar el 

calentador.

8.      

ADVERTENCIA

Riesgo  de  incendio.  Para  evitar  posibles 

incendios,  no  bloquee  las  tomas  de  aire  ni  el 

escape de manera alguna.

9.      

ADVERTENCIA

Podrían  producirse  explosiones  o  incendios. 

Todo calentador contiene piezas que se calientan 

y  pueden  producir  arcos  voltaicos  o  chispas. 

No lo use en áreas donde se utilice o almacene 

gasolina, pintura o vapores o líquidos inflamables.

10. Use este calentador sólo como se describe en 

este manual. Todo otro uso no recomendado por 

el fabricante puede causar incendios, descargas 

eléctricas o lesiones personales.

11. El calentador debe instalarse correctamente 

antes de usarlo.

12.     

ADVERTENCIA

Riesgo de electrocución e incendio. No lo opere 

sin la rejilla.

13. Conserve estas instrucciones.

Página 10

Содержание Energy Plus CE083T

Страница 1: ... within one degree Our newest and most thoughtful design features Large digital display shows your room temperature and heating mode Easy intuitive one touch controls Night Away and Max Min options for extra savings and safety Improve air circulation add comfort in off season with three fan speeds Easily replaces many Com Pak Series heaters C CB CM CS FX or X Installs in 3 easy steps and power sup...

Страница 2: ...t power at service panel and have heater inspected by a qualified electrician before reusing 5 WARNING Do not use outdoors 6 To disconnect heater turn controls to off and turn off power to heater circuit at main disconnect panel 7 WARNING Risk of Electrical Shock Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire or damage...

Страница 3: ...y in lower positions but must not be lower than 4 inches above the floor If you are replacing a heater the Cadet Energy Plus heater must only be installed with a Com Pak style wall can model FXC XC CC Check the label in the existing wall can to make sure this is the type you are replacing Be sure that your existing or new wall can is mounted flush with the outside of the sheetrock The heater has a...

Страница 4: ...d May not be used with a wall thermostat REQUIRED MINIMUM distance of 6 inches from adjacent surfac es and 4 1 2 inches from the floor See Figure 4 However Cadet RECOMMENDS 12 inches from adjacent surfaces and floor for longer and cleaner performance Heaters must be spaced at least 3 feet apart Secure the wall can to the stud with 2 screws See Figures 1 2 As an option the rubber shim provided may ...

Страница 5: ...m edge of the heater assembly on the bottom of the wall can while supporting the edge closest to you See Figure 8 Connect the supply wires to the heater wires with connectors See Figure 9 or Figure 9a Now rotate heater assembly into wall can so that the bottom edge drops into the half round slots in bottom lip of wall can See Figure 10 IMPORTANT Push wires into bottom and left side of wall can dur...

Страница 6: ...n to your previous night away set point simply push the Night button You can preset a maximum and or minimum set point as a child safety or tamper proof option To preset a maximum setpoint Move rocker switch to NO HEAT mode Press and hold both the Night button and the Up button at the same time for at least 5 seconds until the HL high limit is displayed Release buttons temperature setpoint will fl...

Страница 7: ... product at the end of its useful life Contact your local recycling support center for further recycling instructions The heater is protected by a temperature limiting control The manual reset temperature limit control is designed to open the heater circuit when excessive operating temperatures are detected The problem must be assessed typically the heater is blocked or needs cleaning and the limi...

Страница 8: ...tions 1 Clean heater See Maintaining Your Heater section for instructions 2 Turn off power at circuit breaker Inspect all supply and heater wires for loose or poor connections Secure or reconnect all loose connections Do not reset circuit breaker until all connections have been checked or repaired Element heats for a moment without the fan turning then immediately stops heating 1 Defective motor o...

Страница 9: ...antalla digital en la que aparece la tempera tura ambiente y el modo de calentamiento Controles sencillos e intuitivos con un solo toque Las opciones de Noche Ausencia y Máx Mín apor tan más ahorro y seguridad Mejora la circulación del aire brinda mayor como didad fuera de la temporada fría con un ventilador de tres velocidades Reemplaza fácilmente muchos calentadores de la serie Com Pak C CB CM C...

Страница 10: ...de niños o de personas inválidas y cada vez que lo deje funcionando sin vigilancia 4 ADVERTENCIA Riesgo de electrocución No opere ningún calentador después de una avería Desconecte la alimentación en el panel de servicio y pida a un técnico electricista calificado que lo revise antes de volver a usarlo 5 ADVERTENCIA No lo use a la intemperie 6 Para desconectarlo ponga los controles en OFF y apague...

Страница 11: ...o digital Funcionará debidamente en posiciones inferiores pero no debe ser inferior a 4 pulga das sobre el piso Si va a reemplazar un calentador el Energy Plus de Cadet sólo se debe instalar con una cámara de pared estilo Com Pak modelo FXC XC CC Revise el rótulo en la cámara de pared actual para cerciorarse de que este es del tipo de la que va a reemplazar Cerciórese de que la cámara de pared exi...

Страница 12: ...deje al menos tres pies entre ellos Corte un orificio de 8 pulgadas de ancho por 10 de alto al lado del puntal de la pared Inserte la cámara de pared en la abertura manteniéndola alin eada con la superficie de la pared Asegure la cámara al puntal de la pared con 2 tornillos mediante los orificios que vienen en la cámara IMPORTANTE la cámara de pared se debe montar al ras con la parte exterior de l...

Страница 13: ...acia usted Puede apoyar el borde inferior del conjunto del calentador en la parte inferior de la cámara de pared apoyando simultáneamente el borde más próximo a usted vea la figura 8 Empalme los alambres de suministro con los del calentador mediante conectores consulte la figura 9 o la figura 9a Ahora gire el conjunto del calentador hacia la cámara de pared de modo que el borde inferior caiga en l...

Страница 14: ...odo NO HEAT SIN CALOR Oprima sin soltar el botón de Noche y el botón Ascendente al mismo tiempo durante al menos 5 segundos hasta que aparezca HL límite alto en pantalla Suelte los botones el punto de ajuste de temperatura destellará alter nadamente con HL en la pantalla Utilizando el botón Ascendente o Descendente fije el punto de ajuste máximo que desee Gire el interruptor basculante de vuelta a...

Страница 15: ...l cual está diseñado para abrir el circuito del calentador cuando se detectan temperaturas de funcionamiento excesivas El problema debe evaluarse generalmente el calentador está bloqueado o hay que limpiarlo y el límite debe restablecerse para que el calentador vuelva a funcionar Acerca del control de límite de temperatura de reglaje manual Cómo restablecer el control limitador de temperatura de r...

Страница 16: ...suministro y del calentador para comprobar que no estén dañados No reestablezca el cortacircuito sino hasta que se hayan reparado todos los cortocircuitos eléctricos 3 Vuelva a colocar el cortacircuito 4 Reemplace el conjunto del calentador El ventilador del calentador funciona pero no envía aire caliente 1 El interruptor basculante no está fijado en el modo HEAT CALOR 2 El elemento ha fallado 1 G...