17
UTENTE WALL3 PLUS_TILE3 PLUS_ MOON_LEAN3 PLUS_EN
-5= 5% reduction with respect to the default setting.
0= No variation.
+5= 5% increase with respect to the default setting.
+10 = 10% increase with respect to the default setting.
+15 = 15% increase with respect to the default setting.
9.18 SMOKE RPM VARIATION (SEE SECTION I SETTINGS MENU A PAG. 10)
If the installation presents difficulties for smoke evacuation (no draught or no pressure in the duct), the smoke and ash expulsion
speed can be increased. This change resolves all the potential problems related to pellets clogging in the brazier and deposits
forming at the bottom of the brazier itself caused by poor quality fuel or fuel that produces a lot of ashes. The values available are
from -27% to +27% with variations of 3 points at a time. The variation in negative can be used in case the flame is too low.
9.19 CHIMNEY SWEEP FUNCTION (FOR MAINTENANCE TECHNICIANS ONLY) - SEE SECTION K SET-
This function can be activated only when the boiler is on and with power output and heating operation power with parameters
P5, with fan (if present) in V5. Any loading/smoke ventilation percentage corrections must be taken into account. This status lasts
20 minutes, the countdown is displayed on the panel. At any time the technician can interrupt this stage by quickly pressing the
on/off key.
9.20 COMFORT MODE FUNCTION
“COMFORT MODE” this function allows activating-deactivating the fans at power 1.
The Comfort Mode option can ONLY be excluded for ducted stoves.
9.21 LOAD TIME-OUT AND PELLET OPERATION TIMER FUNCTION
The loading system stops when the tank door is opened.
“LOAD TIME-OUT”
: the control unit is equipped with a timer that acoustically warns (with 3 beeps) that the load time available
is over.
If the user requires more time to finish loading the tank, after the acoustic signal, he/she must quickly close the tank cover and
wait 5-6 seconds. In this way the timer resets and the screw starts to let the pellet down again.
After those 5-6 seconds, open the tank lid again and proceed to load the pellet. During this operation, check that the flame is
present on the brazier.
10 FUEL
10.1 FUEL
• Use top-quality pellets because they have influence in the calorific value and in ash remains.
• Pellets features are: dimension Ø6-7mm (D06 Class), maximum lenght 40 mm, calorific value 5kWh/kg, humidity ≤ 10%, ash
remains ≤ 0,7%, they must be correctly pressed and not much mealy, without sizing agents, resins and other additives (class
A1 pellets according to ISO 17225-2 (type ENplus-A1) are recommended).
• Not adequate pellets cause a bad combustion, a frequent burning pot obstruction and exhaust conduits obstruction. Further it
decreases the calorific value, soils the glass and increases consumptions and ash and unburnt granules quantity.
Humid pellets cause a bad combustion and running, so please assure you that they are stored in dry places and
far at least one meter from the stove and/or any other source of heat.
• It is advisable to try different type of pellets available on the market and to choose that which gives the best performance.
• The use of bad quality pellets can damage the stove so that the warranty and manufacturer liability fall.
• Pellets of variable quality and size are available on the market: the smaller the pellet, the greater the fuel supply, resulting in
poor combustion
Depending on the type of pellets it could be necessary a parameters adjustment, please contact an Authorized
Assistance Service.