background image

7

Stufe a pellet

Fig. 5 - Anti-wind chimney pots

Fig. 6 - Reflux area

3.6 

MAINTENANCE

•  The fumes extraction pipes (fumes c chimney flue + chimney pot) must always be cleaned, scrubbed and checked 

by an expert stove-repairer, in compliance with current regulations, with the instructions of the stove-manufacturer and the 

directives of your insurance company.

•  In case of doubts, please follow the most restrictive regulations.

•  Have your chimney flue and chimney pot checked and cleaned by an expert chimney sweep at least once a week. The chimney 

sweep has to release a written declaration about the security of the system.

•  Not cleaning compromise safety.

COMBUSTION AIR

4.1 

AIR INLET

It is mandatory to provide an adequate external air inlet that supplies the combustion air required for the product to work properly. 

The flow of air between the outside and the installation room can take place with a free air inlet or by channelling the air directly 

to the outside

 (***)

.

The free air inlet must:

•  be made at floor level;

•  always be protected with an outer grille and in such a way that it cannot be obstructed by any object;

•  have a minimum total free area of 80 cm

2

 (net of the grille);

The presence of other suction devices (e.g.: vmc, electric fan for stale air extraction, kitchen hood, other stoves, etc.), in the same 

room could cause negative pressure in the room. In this case, with the exception of sealed installations, one must verify that, with 

all the equipment on, no more than 4 Pa of negative pressure is created inside the installation room with respect to the outside. If 

necessary, increase the air inlet section.

It is possible to duct the air required for combustion to the outside by connecting the external air inlet directly with the combustion 

air inlet which is usually found on the back of the appliance.

The duct must comply with the following dimensions (each 90° bend is equivalent to one linear metre):

(***)

 

In the event the combustion air is ducted on unsealed products, still verify that no more than 4 Pa of negative pressure is created 

inside the installation room with respect to the outside, otherwise provide for an additional air intake in the room.

Содержание SOUND3 5 UP

Страница 1: ...7 0 SWEET3 7 7 0 PERLA3 7 7 0 CRISTAL3 7 7 0 ONE AIRTIGHT BEAM AIRTIGHT ACCENT AIRTIGHT SHARP AIRTIGHT LEE AIRTIGHT SOUND3 5 7 UP CHROME 5 7 AIRTIGHT ROUND 5 7 AIRTIGHT FLOYD 5 0 7 0 2022CADELsrl Allr...

Страница 2: ...REMOVAL ASSEMBLY OF BACK PANELS PERLA3 7 0 20 6 10 TILES ASSEMBLY PERLA3 7 0 20 6 11 REMOVAL ASSEMBLY OF METAL TILE PROFILES PERLA3 7 0 20 6 12 MOUNTINGTHE STAND ACCENT AT 21 6 13 REMOVAL ASSEMBLY OF...

Страница 3: ...ialized Stove repairer WARNING symbols indicates an important note 2 PACKAGING AND HANDLING 2 1 PACKAGING ThepackagingismadeupofrecyclablecardboardboxesaccordingtoRESYstandards recyclableexpandedpolys...

Страница 4: ...h the utmost care 3 CHIMNEY FLUE 3 1 PREPARING THE SMOKE EXPULSION SYSTEM The combustion product expulsion system is a particularly important element for the proper operation of the appliance and must...

Страница 5: ...mt 10 mt Maximum length with 3 unions 4 5 mt 8 mt Maximum number of unions 3 3 Level section minimum inclination 3 4 mt 4 mt Installation at a height above 1200 m a s l NO Obligatory 3 4 FLUE CHIMNEY...

Страница 6: ...internal section of the chimney prevent the penetration of rain or snow ensure the outlet of smoke even in the event of wind windproof chimneypot the height of outflow must be beyond the reflux area...

Страница 7: ...free air inlet must be made at floor level always be protected with an outer grille and in such a way that it cannot be obstructed by any object have a minimum total free area of 80 cm2 net of the gri...

Страница 8: ...mm 1 m 80 mm 3 m 1 m 100 mm 7 m 4 m Fig 7 Directairinflow Fig 8 Airinletforsealed chamberinstallation LEGEND Fig 7 Fig 8 1 Roomtoventilate 2 Externalairinlet 4 Shieldgrid 5 Curveinlettoturndownwards...

Страница 9: ...es install suitable insulation between the flue and the ceiling Always check and comply with the plate data of the flue specifically the minimum safety distances from combustible materials The previou...

Страница 10: ...84 1 which is resistant to soot fire and which complies with the distances prescribed by the combustible materials indicated on the plate data there is a suitable combustion air flow to the appliance...

Страница 11: ...furniture curtains or sofas as a precaution increase the stove clearances substantially to avoid possible deterioration due to the effect of heat Fig 11 Safetydistancesfromcombustiblematerial LEGENDA...

Страница 12: ...by at least 50 cm from adjacent walls without emptying the system e g by using a double shut off gate or suitable flexible connection 1 The national reference standard for the installation of domesti...

Страница 13: ...6 13 1cm 7 20 5cm 8 Exhaustfumesd 8cm 9 Holecombustionairinletd 6cm Fig 14 Generaldimensions PERLA3 7 7 0 LEGEND Fig 14 1 94cm 2 52 1cm 3 45 6cm 4 21 3cm 5 32 4cm 6 16 5cm 7 20 5cm 8 Exhaustfumesd 8cm...

Страница 14: ...B Holecombustionairinletd 6cm Fig 16 Generaldimensions SHARPAIRTIGHT LEEAIRTIGHT LEGENDE Fig 16 A Exhaustfumesd 8cm B Holecombustionairinletd 6cm Fig 17 Generaldimensions SOUND35UP 7UP LEGENDE Fig 17...

Страница 15: ...Dimensionigenerali SOUND5PS 7PS LEGENDE Fig 18 A Exhaustfumesd 8cm B Holecombustionairinletd 6cm Fig 19 Generaldimensions CHROME5 7AIRTIGHT ROUND5 7AIRTIGHT LEGEND Fig 19 A Exhaustfumesd 8cm B Holeco...

Страница 16: ...OYD5 0 7 0 LEGEND Fig 20 A Exhaustfumesd 8cm B Holecombustionairinletd 6cm Fig 21 Generaldimensions ONE BEAM AIRTIGHT LEGEND Fig 21 1 95 2cm 2 46cm 3 45 2cm 4 18 9cm 5 31 4cm 6 13 6cm 7 20 2cm 8 Exhau...

Страница 17: ...NSTALLATION For some operations e g side panel assembly and cleaning you must remove the stove door To remove the door Open the door Undo the screws from the upper hinge see Fig 23 Remove the hinge ke...

Страница 18: ...6 REMOVAL ASSEMBLY OF SIDE PANELS SWEET3 7 0 ONE AT BEAM AT ACCENT AT ACCENT K AT To disassemble the side panels proceed as follows Undo the rear screws see Fig 29 Open the side panel see Fig 30 and r...

Страница 19: ...6 Fix the complete side panel on the front and back see Fig 37 To assemble proceed in reverse order Fig 35 Removetheblackprofile Fig 36 Fixthecolouredsidepanel Fig 37 Fixthecompletesidepanel 6 9 REMOV...

Страница 20: ...0 Tilesassembly 6 11 REMOVAL ASSEMBLY OF METAL TILE PROFILES PERLA3 7 0 To disassemble the front profiles proceed as follows Undo the front screws of the profile see Fig 41 Open the panel and release...

Страница 21: ...ed in reverse order Fig 44 Unscrewthescrews Fig 45 Releasethesidepanels 6 14 INSTALLATION OF TEE FITTING EXCLUDING SOUND 3 UP CHROME AT FLOYD MODELS For stoves with top exhaust a tee fitting with insp...

Страница 22: ...DECOUPLED ONLY MODELS CHROME ROUND FLOYD SOUND The stove is designed to be connected to the flue by means of a concentric hose through the specific preinstalled fitting If different requirements make...

Страница 23: ...thorizedtechnician The electric connection occurs through a cable with plug put in an electric socket which is able to support charge and tension specific of every model as described in the technical...

Страница 24: ...ws to Settings Select by pressing menu Scroll with the arrows again to Ext Thermostat Select by pressing menu Press the buttons To activate the external thermostat select on Press the menu button to c...

Страница 25: ...25 26 Pa 190 C 29 30 Pa 200 C 34 35 Pa 220 C 40 41 Pa 240 C 47 48 Pa 250 NB for good combustion the depression values must be between 5 Pa and the temperature values between 10 C 7 SPECIAL MAINTENANC...

Страница 26: ...and if necessary replace it Itisimportanttosealedthecapothrwisenoxiuousfumeswillpropagateamongtheroom 7 3 FUME CONDUIT CLEANING ROUND STOVES The exhaust system must be cleaned every 2 3 months Unscrew...

Страница 27: ...anwithpipecleaner Fig 71 Vacuumouttheash Clean with a pipe cleaner and suction any ash accumulated inside see Fig 70 and Fig 71 After cleaning repeat the operation in reverse making sure the gasket is...

Страница 28: ...t He will also check their eficiency and will release a written declaration of the safety of the appliance This operation must be executed at least once a year 7 7 GASKET REPLACEMENT Incaseofdeteriora...

Страница 29: ...n fire door or open pellet door Close fire door and pellet door and check that there are no pellet grains at the gasket level Clogged stove Fume chamber cleaning Auger blocked by a foreign object for...

Страница 30: ...Faulty fume tempe rature probe Replace the fume probe Faulty mother board Replace the mother board Ash remains along the stove Faulty or out of order door gaskets Replace the gaskets Not sealed fume...

Страница 31: ...ows Remove the frame see the dedicated chapters After these operations you can have access at the following components geared motor ignition plug ambient fan fume fan ambient probe fume probe thermost...

Страница 32: ...13 O2 Max 18 15 mg Nm3 18 15 mg Nm3 18 15 mg Nm3 CHIMNEY DEPRESSION Max 10 Pa 10 Pa 10 Pa ON SHARED CHIMNEY FLUE NO NO NO FUME OUTLET DIAMETER 80 mm 80 mm 80 mm COMBUSTIBLE Pellet 6 7 mm Pellet 6 7 mm...

Страница 33: ...TS at 13 O2 Max 20 15 mg Nm3 20 15 mg Nm3 20 15 mg Nm3 CHIMNEY DEPRESSION Max 10 Pa 10 Pa 10 Pa ON SHARED CHIMNEY FLUE NO NO NO FUME OUTLET DIAMETER 80 mm 80 mm 80 mm COMBUSTIBLE Pellet 6 7 mm Pellet...

Страница 34: ...ENTS at 13 O2 Max 18 15 mg Nm3 20 15 mg Nm3 CHIMNEY DEPRESSION Max 10 Pa 10 Pa ON SHARED CHIMNEY FLUE NO NO FUME OUTLET DIAMETER 80 mm 80 mm COMBUSTIBLE Pellet 6 7 mm Pellet 6 7 mm PELLETS HEATINGVALU...

Страница 35: ...TENTS at 13 O2 Max 20 15 mg Nm3 20 15 mg Nm3 20 15 mg Nm3 CHIMNEY DEPRESSION Max 10 Pa 10 Pa 10 Pa ON SHARED CHIMNEY FLUE NO NO NO FUME OUTLET DIAMETER 80 mm 80 mm 80 mm COMBUSTIBLE Pellet 6 7 mm Pell...

Страница 36: ...TS at 13 O2 Max 20 15 mg Nm3 20 15 mg Nm3 20 15 mg Nm3 CHIMNEY DEPRESSION Max 10 Pa 10 Pa 10 Pa ON SHARED CHIMNEY FLUE NO NO NO FUME OUTLET DIAMETER 80 mm 80 mm 80 mm COMBUSTIBLE Pellet 6 7 mm Pellet...

Страница 37: ...t 13 O2 Max 20 15 mg Nm3 20 15 mg Nm3 20 15 mg Nm3 CHIMNEY DEPRESSION Max 10 Pa 10 Pa 10 Pa ON SHARED CHIMNEY FLUE NO NO NO FUME OUTLET DIAMETER 80 mm 80 mm 80 mm COMBUSTIBLE Pellet 6 7 mm Pellet 6 7...

Страница 38: ...NOTE...

Страница 39: ...NOTE...

Страница 40: ...CADEL srl 31025 S Lucia di Piave TV Via Foresto sud 7 Italy Tel 39 0438 738669 Fax 39 0438 73343 www cadelsrl com www free point it www pegasoheating com Rev 02 2022...