Stufe a pellet
24
• Do not use extension cables.
• If the feeder cable is damaged, it must be replaced by an authorized technician.
• When the stove is not going to be used for a long period of time, it advisable to remove the plug from the socket on the wall.
• An electrical connection to a UPS/ACCUMULATOR/ STABILISER must guarantee a voltage of at least 210 V without power
surges. Considering the variety of UPS on the market regarding size and construction qualities, we cannot guarantee operation
once the stove is connected to these devices.
6.19 CONNECTION TO THE EXTERNAL THERMOSTAT
Fig. 59 - Graphic display
The stove works through a thermostat probe placed in its inner. If you desire, the stove can be connected to an external room
thermostat. This operation must be executed by an authorized technician.
Connect the wires from the external thermostat to the "Term opt" terminal on the stove board. Activate the external thermostat
(default setting OFF) as indicated below:
• Press the "
menu
" button.
• Scroll with the arrows to "
Settings
".
• Select by pressing "
menu
".
• Scroll with the arrows again to "
Ext.Thermostat
".
• Select by pressing "
menu
".
• Press the
- +
buttons.
• To activate the external thermostat select "
on
".
• Press the "
menu
" button to confirm.
6.20 CONNECTION TO THE EXTERNAL THERMOSTAT
Fig. 60 - 3-key display
The stove works through a thermostat probe placed in its inner. If you desire, the stove can be connected to an external room
thermostat. This operation must be executed by an authorized technician.
Connect the wires from the external thermostat to the "Term opt" terminal on the stove board. Activate the external thermostat
(default setting OFF) as indicated below:
• Press the menu key for a few seconds (1).
• Repeatedly press the P2 key until
M8 - Technical settings
"
M8-SEt tEcHnic
" appears.
• Select by pressing the P3 key.
• Set the password with keys P1 or P2 (keeping the key pressed accelerates the setting).
• Confirm by pressing the P3 key.
• Press the P1 or P2 keys until
M8 - 2 General settings
"
M8-2 SEt GEnErAL
" appears.
• Confirm with P3.
• Scroll with the P3 key up to:
Pr46 Enable Remote
"
Pr46 rEMoto EnAbLEd
".
• Press the P1 or P2 key to modify the status.
• Confirm with the P3 key.
• Scroll to
MB Output
"
Mb EScAPE
" with key P1 or P2.
• Confirm with P3 key.
•
Содержание SOUND3 5 UP
Страница 38: ...NOTE...
Страница 39: ...NOTE...