ATRIUM AT 5kW-ROXY-MADISON-SOLO-TABLA
28
ALARM
CAUSE
SOLUTION
INTERVENTION
AL 5 - FAILED
IGNITION
Empty hopper
Fill the hopper.
The burning pot has not
been cleaned
Clean the burning pot.
The ignition threshold has
not been reached
Clean the burning pot and switch the stove on again.
Faulty ignition plug
Replace the ignitor resistance.
Too sever external tempe-
rature
Start the stove up again.
Humid pellet
The pellets must be stored in a dry place. Please check it.
Blocked thermal probe
Replace the thermal probe.
Faulty mother board
Replace the mother board.
AL 6 - NO PELLET Empty hopper
Full the hopper.
AL 7 - THERMAL
SAFETY
Boiler overheating
Let the stove cooling. (If the problem persits please call an
Authorized Technician).
The ambient exchanger fan
does not work
Replace the ambient fan.
Temporary power cut
The lack of tension during the running implies the overheating
of the boiler and the intervention of the manula reset thermo-
stat. Let the stove cooling, reset and start the stove up again.
Faulty manual reset ther-
mostat
Replace the manual reset thermostat.
Faulty mother board
Replace the mother board.
Содержание ROXY