Cadel ROXY Скачать руководство пользователя страница 21

21

ATRIUM AT 5kW-ROXY-MADISON-SOLO-TABLA

When the flue gas temperature has reached and exceeded the intended value, the stove goes into the normal operating mode. The 

display shows the word 

Work

 " 

uorK 

" and the ON/OFF LED is lit. 

The power can be set by keeping button P2 pressed and the room temperature can be set by pressing button P1.

At set intervals, an automatic burn pot cleaning is performed in order to prevent dash from accumulating. On the display you will 

see 

Cleaning fire-pot

 “

cLEAninG FirE-Pot

”.

If this function lasts for a few seconds, it is NOT an alarm.

Fig. 19 - Display

8.5 

FAILED IGNITION

If the pellets do not burn, the failed ignition will be indicated by the alarm 

AL 5 FAILED IGNITION 

AL 5 ALAr no LiGHtin 

".

If the room temperature is lower than 10°C, the plug is not able to bear the ignition stage. To support it please insert some pellets 

in the burning pot and a piece of burning firelighter igniter material on the pellets (for example firelighters cubes).

Too much pellets in the burning pot, or humid pellet, or sooty burning pot make ignition difficult and create dense white smoke 

which is harmful to health and can cause explosions on the combustion chamber. It is therefore necessary not to stand in front of 

the stove during ignition stage if dense white smoke is present.

If after some months the flame appears weak and/or orange colored or the glass tends to blackens and the 

burning pot to become encrusted, clean the stove, clean the fume conduit and the chimney flue.

8.6 

POWER FAILURE

After a 

Black-out 

bLAc-out 

" lower than 5 seconds, the stove turns back to the power which was settled.

After a 

Black-out 

 " 

bLAc-out 

"of more than 5 seconds, the stove enters the 

COOLING WAIT 

uAit cooLinG 

" phase. Completed this 

phase, it starts automatically up with the different phases (see 

STOVE SWITCH-ON a pag. 20

).

8.7 

TEMPERATURE SETTING

Change the room temperature by simply pressing button 

P1

The display shows the set room temperature (

temperature SETTING

). 

Therefore, the value can be changed by pressing buttons 

P1 (decreases) and P2 (increases

). 

After about 5 seconds the value is saved and the display returns to normal display, or exit by pressing 

P3

.

8.8 

POWER SETTING

Change the set power by simply pressing button P2. The display shows the set power (power SETTING). Therefore, the value can be 

changed by pressing buttons 

P1 (decreases) and P2 (increases

).

After about 5 seconds the value is saved and the display returns to normal display, or exit by pressing P3.

NOTE: when the room temperature has reached the set value, the heating power of the stove is automatically brought to the mi-

nimum value. In these conditions, the display shows the message 

Modulate 

“ 

ModuLAt 

”.

If the room temperature drops below the set temperature, the stove returns to “

Work

 " 

uorK 

" mode at the previously set power.

8.9 

SWITCHING OFF

Switch the stove off by simply pressing and holding down button P3. Pul-Finale 

"cLEAninG SPEEd

"  appears on the display.

After a certain time, the stove switches off, and 

Off

  "

oFF 

" is displayed.

8.10  CONNECTION TO THE EXTERNAL THERMOSTAT

The stove works through a thermostat probe placed in its inner. If you desire, the stove can be connected to an external room 

thermostat. This operation must be executed by an authorized technician.

Содержание ROXY

Страница 1: ...EN USER MANUAL Pellet Stove ROXY ATRIUM 5 AIRTIGHT TABLA SOLO 5 MADISON 5 OriginalInstructions 2022CADELsrl Allrightsreserved Tuttiidirittiriservati new...

Страница 2: ...ITCHING OFF 20 8 10 CONNECTIONTOTHE EXTERNALTHERMOSTAT 20 9 FUEL 21 9 1 FUEL 21 9 2 PELLET SUPPLY 21 9 3 PELLET REFUELLINGTIMER 22 10 VENTILATION 22 11 REMOTE CONTROL OPTIONAL 22 12 SAFETY DEVICES AND...

Страница 3: ...gthosereferringtonationalandEuropeanstandards mustbeobservedwheninstallingtheappliance In Italy for the installation of systems with a biomass below 35KW refer to the Ministerial Decree 37 08 and the...

Страница 4: ...perating conditions increase the risk of premature wear of the product especially those parts exposed to the direct heat of the fire e g combustion chamber theoriginalconditionofwhichcanundergomodific...

Страница 5: ...1 meter If the floor is made of combustible material we recommend using a protector made of in combustiblematerial steel glass etc thatalsoprotectsthefrontpartfromanyfallingburnt particles during clea...

Страница 6: ...uetothepaintheatingupforthefirsttime Therefore make sure the room it is installed in is well ventilated Periodically check and empty the inspectionable parts of the smoke duct e g Tee fitting caps Hav...

Страница 7: ...document to theTechnical Assistance Office Theguaranteedoesnotcovermalfunctionsand ordamagetotheappliancethatariseduetothefollowingcauses Damage caused during transportation or relocation All parts th...

Страница 8: ...ARNINGS FOR THE CORRECT DISPOSAL OF THE PRODUCT The owner is the sole party responsible for demolishing and disposing of the product This must be performed in compliance with laws related to safety an...

Страница 9: ...LATORS Fig 2 Wastedisposal Thissymbol whichisusedontheproduct batteries accumulatorsoronthepackagingordocuments meansthatattheendofits useful life this product the batteries and the accumulators inclu...

Страница 10: ...LASTIC Check the instructions of the com petent body STRAP TAPE POLYPROPYLENE PP 5 SORTED waste collection PLASTIC Check the instructions of the com petent body SCREWS STAPLES FOR STRAP FASTENING BRAC...

Страница 11: ...imney flue is efficient Switch on the stove at Power 5 for at least 2 hours in order to enable the materials which make up the boiler and the fireplace to adjust the inner springing stress After 2 hou...

Страница 12: ...ove s operating status Meaning of the buttons see Fig 5 Fig 5 Display 3buttons REFERENCE BUTTON DESCRIPTION MODE ACTION 1 Decreases tempera ture and power TEMPERATURE SETTING Decreases the value of th...

Страница 13: ...iefly describes the menu structure this paragraph solely focuses on the selections available to the user Press the P1 button for 2 seconds to access the general programming menus Pressing P1 decreases...

Страница 14: ...50 03 stop Prg 1 03 StoPPrG1 oFF 0 23 50 04 Monday Prg1 04 MondPrG1 on oFF 05 Tuesday Prg 1 05 tuESPrG1 on oFF 06 Wednesday Prg 1 06 uEdnPrG1 on oFF 07 Thursday Prg1 07 tHurPrG1 on oFF 08 Friday Prg...

Страница 15: ...F 33 Wednesday Prg 4 33 uEdnPrG4 on oFF 34 Thursday Prg4 34 tHurPrG4 on oFF 35 Friday Prg 4 35 FridPrG4 on oFF 36 Saturday Prg 4 36 SAtuPrG4 on oFF 37 Sunday Prg 4 37 SundPrG4 on oFF M2 4 Weekend prog...

Страница 16: ...A Flue type MAtyPEcHiMnEy 01 Flue extractor 01 Pr55SMoKEcHiMnEy da 9 a 9 MB Exit MbEScAPE 01 Exit 01 EScAPE set 8 3 1 Menu M1 CLOCK SETTING Set the current time and date The board has a lithium batter...

Страница 17: ...StoP 2 dAyLy deactivation time OFF 0 23 50 Submenu M2 3 weekly program TheM2 3WeeklyProgram ProGrAMuEEK menuallowsyoutoenable disableandsettheweeklychronothermostatfunctions The weekly function has 4...

Страница 18: ...37 Sund PrG4 on off Submenu M2 4 weekend program Allows you to enable disable and set the weekend chronothermostat functions day 6 and 7 i e Saturday and Sunday Enable by pressing the P3 button in 01...

Страница 19: ...M6 themessagePressMore PrESSMorE willscrollonthedisplay seeFig 13 ThenpressP2 increases Thefluegasfanturnsonatmaximumspeed thefeedscrewturnson feedscrewLEDon andthey remain until the time indicated on...

Страница 20: ...icalpersonnelwhocheckthateverything is installed according to the regulations in force and verifies its functionality If inside the combustion chamber there are booklets manuals etc remove them Check...

Страница 21: ...lack out bLAc out lower than 5 seconds the stove turns back to the power which was settled AfteraBlack out bLAc out ofmorethan5seconds thestoveenterstheCOOLINGWAIT uAitcooLinG phase Completedthis phas...

Страница 22: ...nAuthorized AssistanceService The main quality certifications for pellets currently available on the European market guarantee that the fuel complies with class A1 A2accordingtoISO17225 2 Thesecertifi...

Страница 23: ...soff The loading system stops when the tank door is opened Before closing the lid make sure there are no pellets below the gasket Pellets deteriorate the gasket and eliminateitsairtightsealing vediFig...

Страница 24: ...clogged exhaust Significant negative wind clogged fume passages open pellet loading tank open fire door or worn broken gaskets see SMOKE RPMVARIATION User Manual 12 2 SMOKE TEMPERATURE PROBE Detects...

Страница 25: ...performs a cooling phase to the maximum 2 Performs a new ignition The display will show the message Al 1 alar al 1 Blac out AL1bLAc out see Fig 27 and the stove will shut down Fig 27 Display AL1 12 1...

Страница 26: ...L6 12 15 THERMAL SAFETY OVERHEATING ALARM Occurs when the general safety thermostat detects a temperature above the trigger threshold The thermostat triggers and turns off the feed screw indicating th...

Страница 27: ...cted fume tempe rature probe Have the stove checked Faulty fume temperature probe Replace the fume probe AL 3 HOT EXHAUST Faulty fume probe Replace the fume probe Faulty mother board Replace the elect...

Страница 28: ...check it Blocked thermal probe Replace the thermal probe Faulty mother board Replace the mother board AL 6 NO PELLET Empty hopper Full the hopper AL 7 THERMAL SAFETY Boiler overheating Let the stove c...

Страница 29: ...e P3 button pressed for some time The stove performs a check to determine whether the warning cause is still present If this is the case the warning will be shown again otherwise the stove will switch...

Страница 30: ...BERTHATONLYACORRECTLYPOSITIONEDANDCLEANBRAZIERCANGUARANTEESTART UPANDOPTI MALOPERATIONOFYOURPELLETPRODUCT For the brazier to be cleaned properly remove it from its housing completely and thoroughly cl...

Страница 31: ...t they must be removed with the aid of a vacuum cleaner see Fig 41 13 5 FUME PIPES ANNUAL CLEANING Clean annually from soot with brushes The cleaning operation must be executed by a specialized stove...

Страница 32: ...reorTechnicalAssistanceCentre during thenecessaryannualendofseasonscheduledmaintenanceoperations Thiswaythepaintwillprotecttheinnerpartsofthecom bustion chamber blocking any type of oxidative process...

Страница 33: ...LEM SOLVING Before of every Authorized Technician intervention the same Technician has the duty to check if the parame tersofthemotherboardcorrespondtothoseofthetableyouown Incaseofdoubtsregardingtheu...

Страница 34: ...LARM Have the stove checked The fire extinguish and the stove stops Empty hopper Full the hopper Auger blocked by a foreign object for example nails Clean the auger Bad quality pellets Try other types...

Страница 35: ...just cooled Faulty fume tempe rature probe Replace the fume probe Faulty mother board Replace the mother board Ash remains along the stove Faulty or out of order door gaskets Replace the gaskets Not...

Страница 36: ...Nm3 Heat output Nominal heat output Pnom 7 kW Minimum heat output indicative Pmin 2 7 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom 89 5 Useful efficiency at min...

Страница 37: ...13 O2 121 mg Nm3 Heat output Nominal heat output Pnom 5 2 kW Minimum heat output indicative Pmin 2 5 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom 89 5 Useful e...

Страница 38: ...NOTE...

Страница 39: ...NOTE...

Страница 40: ...Rev 00 2023 CADEL srl 31025 S Lucia di Piave TV Via Martiri della Libert 74 Italy Tel 39 0438 1520200 www cadelsrl com www free point it www pegasoheating com...