This operation
(1*)
must be performed by a technician qualified to disconnect the combustion product expulsion ducts and their
subsequent restoration.
For generators connected to the hydraulic system, a connection must be provided between the system itself and the product so
that, during extraordinary maintenance, carried out by a qualified technician, it is possible to move the generator 1 by at least 50
cm from adjacent walls without emptying the system (e.g. by using a double shut-off gate or suitable flexible connection).
(1*)
The national reference standard for the installation of domestic appliances is UNI 10683 (IT) - DTU NF 24.1 (FR) - DIN 18896
(DE) - NBN B 61-002 (BE) - Real Decreto 1027/2007 (ES) Paesi Bassi (NL) Bouwbesluit - Danmark (DK) BEK n° 541 del 27/04/2020.
6.3
OVERALL DIMENSIONS
6.3.1 RIVER IDRO (T2) 16 - 23 - 23 H
2
O DIMENSIONS
Fig. 15 - RIVER IDRO 16 - 23 - 23 H
2
O
LEGEND
A
Hole combustion air inlet d.5 cm
B
Exhaust fumes d.8 cm
6.3.2 MIRA 16 -22 - TESIS 16 - 23 - (T2) AIRTIGHT DIMENSIONS
Fig. 16 - Mira 16-22 / Tesis16-23 Airtight