31
MARTINA - VANESSA - ALESSIA - SOLARIS
EN
ALARM
CAUSE
SOLUTION
INTERVENTION
ALAR DEP
The fire door is not
correctly closed
Close the fire door correctly and check if the gaskets
are not damaged. (If damaged, have it replaced by an
Authorized Technician)
Obstructed exhaust
The exhaust chimney is partially or totally obstructed.
Please contact an expert stove-repairer who checks
the stove from the exhaust till the chimney pot. Have it
immediately cleaned. It can be noxious to health to let
the stove running with an obstructed chimney.
Out of order fume fan
The pellets can burn also due to the chimney flue
depression without the aid of the fume fan. Have the
fume fan replaced immediately. It can be noxoius to
health to let the stove running without fume fan.
Obstructed connecting
nozzle
Clean the connecting nozzle.
Faulty pressostat
Replace the pressostat.
Faulty mother board
Replace the mother board.
Overlength of the
chimney
Contact an expert stove-repairer and check if the
exhaust chimney is in compliance with the regulations:
Adverse wheather
conditions
In case of strong wind there can be a negative pressure
to the chimney. Check it and switch the stove on again.