IDROSTUFE
30
PROBLEM
CAUSE
SOLUTION
INTERVENTION
Broken or defective
manostat
Replace the manostat
Ignition step is not
completed
Repeat ignition
Temporary power
outage
Wait for automatic restart
Clogged smoke
duct
Clean the smoke duct
Defective or broken
temperature
probes
Check and replace probes
Faulty spark plug
Check and, if necessary, replace the spark plug
Flames are weak
and orange colou-
red, pellets do not
burn properly and
the glass blackens
Not sufficient
combustion air
Check as following: probable obstructions of the combusti-
ble air inlet from the back or from the bottom of the stove;
burning pot obstructed holes with too ash remains. Have the
fan blades and auger cleaned.
Obstructed exhaust
The exhaust chimney is partially or totally obsturcted. Contact
an expert stove-repairer who checks the stove from the
exhaust up to the chimney pot. Provide immediately for stove
cleaning.
Obstructed stove
Provide immediately at the inner cleaning of the stove.
The fume fan is out
of order
The pellets can burn also thanks to chimney flue depression
without the aid of the fume fan. Have the fume fan imme-
diately replaced. It can be noxious to health to let the stove
running without fume fan.
Damp or unsuita-
ble pellets
Change the type of pellet
The exchanger
fan continues to
turn even though
the stove has just
cooled
Faulty fume tem-
perature probe
Replace the fume probe.
Faulty mother
board
Replace the mother board.
Содержание IDRO PRINCE3 12
Страница 44: ...NOTE ...